Proline Prowirl D 200 / 7D2B
Documents / Manuals / Software
-
Proline Prowirl D 200
Technical Information
Low-cost wafer flange design, available as compact or remote device
versionTechnical Information (TI) -
Proline Prowirl D 200
PROFIBUS PA
Operating Instructions
Vortex flowmeter
Operating Instruction (BA) -
Proline Prowirl D 200
FOUNDATION Fieldbus
Operating Instructions
Vortex flowmeter
Operating Instruction (BA) -
Proline Prowirl D 200
HART
Operating Instructions
Vortex flowmeter
Operating Instruction (BA) -
Proline Prowirl 200
PROFIBUS PA
Description of Device Parameters
Vortex flowmeter
Device Parameter (GP) -
Proline Prowirl 200
FOUNDATION Fieldbus
Description of Device Parameters
Vortex flowmeter
Device Parameter (GP) -
Proline Prowirl 200
HART
Description of Device Parameters
Vortex flowmeter
Device Parameter (GP) -
Proline Prowirl D 200
Brief Operating Instructions
Vortex flowmeter
Short Instruction (KA)03/17English -
Replacing the I/O-Module
Installation Instructions
Promass 200 / TB2, Prosonic Flow 200, Promag 200, Prowirl 200
Mounting Instruction (EA) -
Housing filter
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200,Mounting Instruction (EA) -
Activating application packages
Installation Instructions
Promag 100, 200, 400, Promass 100, 200, Prosonic Flow 100, 200, Prowirl
200, t-mass 150Mounting Instruction (EA) -
Sealing set
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200, Remote display FHX50Mounting Instruction (EA) -
Replacing the connection board, pre amplifier, cable harness
Installation Instructions
Prowirl 200
Mounting Instruction (EA) -
Cover
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200, Remote display FHX50Mounting Instruction (EA) -
Replacing the electronics module
Installation Instructions
Prowirl 200
Mounting Instruction (EA) -
Set housing security clamp
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200,Mounting Instruction (EA) -
Replacing the DSC-Sensor and the S-DAT
Installation Instructions
Prowirl 200
Mounting Instruction (EA) -
I/O module
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200,Mounting Instruction (EA) -
Installing sensor parts
Installation Instructions
Prosonic Flow 92F, Prowirl 72, 73, Prowirl 200
Mounting Instruction (EA) -
Conversion Kit for Prowirl 200 Compact Version to Prowirl 200 Remote
Version
Installation Instructions
Prowirl 200 non explosion-protected
Mounting Instruction (EA) -
Replacing the display module
Installation Instructions
Promag 200, Promass 200, Prosonic Flow 200, Prowirl 200, t-mass 150,
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x, Remote dis
play FHX50Mounting Instruction (EA) -
Safety Instructions for Spare Parts
Installation Instructions
Flowmeter
Mounting Instruction (EA) -
Replacing Centering rings
Installation Instructions
Prowirl 72W, 73W, Prowirl D 200
Mounting Instruction (EA) -
Transmitter electronics FHX50
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200,Mounting Instruction (EA) -
Bus plug FF
Installation Instructions
Promag 53, 55, Promag 200, Promass 83, Promass 200, Prowirl 72, 73,
Prowirl 200, Prosonic Flow 92, 93Mounting Instruction (EA) -
Replacing the cover, O-ring cover and the housing seal
Installation Instructions
Prowirl 200 Remote Version
Mounting Instruction (EA) -
Replacing the transmitter
Installation Instructions
Prowirl 200
Mounting Instruction (EA) -
Proline Prowirl 200
NEPSI:
Zone 1, Zone 0/1, Zone 21
Ex i version
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Proline Prowirl 200
INMETRO:
Ex d[ia] IIC T6…T1
Instruções de segurança
Documentação para áreas classificadas
Ex Safety Instructions (XA) -
Proline Prowirl 200
ATEX: II2G, II1/2G, II2D
IECEx: Zone 1, Zone 0/1, Zone 21
Ex d version
Safety Instructions
Documentation for hazardous areas
Ex Safety Instructions (XA) -
Proline Prowirl 200
Cl. I, II, III Div. 1, Zone 0 for IS
(Ex i Intrinsically safe version)
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Proline Prowirl 200
ATEX: II2G, II1/2G, II1G, II2D
IECEx: Zone 1, Zone 0/1, Zone 0, Zone 21
Ex i version
Safety Instructions
Documentation for hazardous areas
Ex Safety Instructions (XA) -
Proline Prowirl 200
NEPSI:
Zone 2
Ex nA version
Ex ic version
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Proline Prowirl 200
ATEX: II3G
IECEx: Zone 2
Safety Instructions
Documentation for hazardous areas
Ex Safety Instructions (XA) -
Proline Prowirl 200
INMETRO:
Ex nA IIC T6…T1
Ex nA[ia Ga] IIC T6…T1
Instruções de segurança
Documentação para áreas classificadas
Ex Safety Instructions (XA) -
Proline Prowirl 200
Cl. I, II, III Div. 1, Zone 1 for XP
(Ex d Flameproofed version)
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Proline Prowirl 200
INMETRO:
Ex ia IIC T6…T1
Instruções de segurança
Documentação para áreas classificadas
Ex Safety Instructions (XA) -
Proline Prowirl 200
NEPSI:
Zone 1, Zone 0/1, Zone 21
Ex d version
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Proline Prowirl 200
Natural Gas application package
Special Documentation
Vortex flowmeter
Natural Gas application packageSpecial Documentation (SD) -
Proline Prowirl 200
Air + Industrial Gases application package
Special Documentation
Vortex flowmeter
Air + Industrial Gases application packageSpecial Documentation (SD) -
Levelflex FMP5x, Micropilot FMR5x
Weather protection cover
Special Documentation (SD) -
Proline Prowirl 200
Functional Safety Manual
Special Documentation
Vortex flowmeter
Special Documentation (SD) -
Information on the Pressure Equipment Directive
Proline flowmeters
Special Documentation
Proline flowmeters
Special Documentation (SD) -
Proline Prowirl 200
Information on the Pressure Equipment Directive
Special documentation
Vortex flowmeter
Special Documentation (SD) -
Change of Directives
Special Documentation
Change of Directives
Special Documentation (SD) -
Proline Prowirl 200
Heartbeat Technology Application Package
Special documentation
Vortex flowmeter
Special Documentation (SD) -
Proline Prowirl 200
Manufacturer information regarding firmware
updates (NE 53)
New firmware version:
Prowirl 200 HART: 1.02.00Manufacturer Information (MI) -
Proline Prowirl 200
Manufacturer information regarding firmware
updates (NE 53)
New firmware version:
Prowirl 200 HART: 1.01.01Manufacturer Information (MI) -
Proline Prowirl 200
Manufacturer information regarding firmware
updates (NE 53)
New firmware version:
Prowirl 200 PROFIBUS PA: 1.01.01Manufacturer Information (MI) -
Mesure de débit dans les circuits auxiliaires
Solutions sur mesure pour la gestion de l'énergie : air comprimé, gaz,
vapeur et eauCompetence Brochure (CP)07/14fr -
Yardımcı işletmelerde akış ölçümü
Basınçlı hava, gaz, buhar ve su için özel enerji yönetimi çözümleri
Competence Brochure (CP)07/14Turkish -
Proline Prowirl 200
The vortex revolution for steam, gas and liquid
Robust, multifunctional, provenInnovations (IN)08/16English -
Proline Prowirl 200
Новое поколение вихревых расходомеров для пара, газов и жидкостей
Innovations (IN)08/13Russian -
Prowirl D 200
Wirbelfrequenz-Durchflussmesser nach dem Vortex-Prinzip als Kompaktgerät
in
Zwischenflansch-Ausführung ohne HilfsenergieTender Text01/16German -
GSD Single, GSD_PA_FL_Prowirl200_0x1564_0x02_0x01, 10.04.2015 (Flow, Prowirl 200)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
GSD Single, GSD_PA_FL_Prowirl200_0x1564_0x01_0x01, 15.07.2014 (Flow, Prow
irl 200, 0x1564)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
EDD Single, AMS11_HART_FL_Prowirl200_0x0038_0x01_0x01, 21.08.2019 (Flow, Prowirl 200, 0x0038)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS_FF_FL_Prowirl200_0x1038_0x01_0x02, 24.10.2016 (Flow, Prow
irl 200, 0x1038)
FOUNDATION Fieldbus H1,
AMS Version: 10.5, 11.5, 12.5, 13.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS10_FF_FL_Prowirl200_0x1038_0x02_0x01, 12.11.2018 (Flow, Prowirl 200, 0x1038)
FOUNDATION Fieldbus H1,
AMS Version: 10.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_Prowirl200_0x0038_0x03_0x01, 21.08.2019 (Flow, Prowirl 200, 0x0038)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_Prowirl200_0x0038_0x03_0x02, 22.03.2018 (Flow, Prowirl 200, 0x0038)
HART,
PDM Version: 8.2.1, 9.1.0.2Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_FF_FL_Prowirl200_0x1038_0x01_0x01, 22.01.2015 (Flow, Prow
irl 200, 0x1038)
FOUNDATION Fieldbus H1,
Field Device Manager Version: R430.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_FL_Prowirl200_0x1564_0x02_0x01, 10.04.2015 (Flow, Prowirl 200)
PROFIBUS PA,
PDM Version: 6.1, 8.2, 9.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_Prowirl200_0x0038_0x01_0x01, 01.04.2014 (Flow, Pr
owirl 200, 0x0038)
HART,
PDM Version: 6.1, 8.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_Prowirl200_0x0038_0x01_0x01, 21.08.2019 (Flow, Prowirl 200, 0x0038)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_FL_Prowirl200_0x0038_0x03_0x01, 21.08.2019 (Flow, Prowirl 200, 0x0038)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_Prowirl200_0x0038_0x04_0x01, 23.11.2018 (Flow, Prowirl 200, 0x0038)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5, 14.0
Delta V Version: 12.3, 13.3Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS14_FF_FL_Prowirl200_0x1038_0x02_0x01, 27.08.2019 (Flow, Prowirl 200, 0x1038)
FOUNDATION Fieldbus H1,
AMS Version: 14.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_FF_FL_Prowirl200_0x1038_0x02_0x01, 12.11.2018 (Flow, Prowirl 200, 0x1038)
FOUNDATION Fieldbus H1,
AMS Version: 12.0, 12.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS10_HART_FL_Prowirl200_0x0038_0x04_0x01, 23.11.2018 (Flow, Prowirl 200, 0x0038)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EDD_FF_FL_Prowirl200_0x1038_0x01_0x02, 20.10.2016 (Flow, Prow
irl 200, 0x1038)
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: AnyElectronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_Prowirl200_0x0038_0x02_0x01, 10.06.2014 (Flow, Prowirl 200, 0x0038)
HART,
PDM Version: 6.1, 8.1, 8.1 SP1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_FF_FL_Prowirl200_0x1038_0x02_0x01, 12.11.2018 (Flow, Prowirl 200, 0x1038)
FOUNDATION Fieldbus H1,
AMS Version: 11.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EDD_FF_FL_Prowirl200_0x1038_0x02_0x01, 28.05.2018 (Flow, Prowirl 200, 0x1038)
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: AnyElectronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_FL_Prowirl200_0x1564_0x01_0x01, 14.04.2014 (Flow, Prow
irl 200, 0x1564)
PROFIBUS PA,
PDM Version: 6.1, 8.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_Prowirl200_0x0038_0x02_0x01, 21.08.2019 (Flow, Prowirl 200, 0x0038)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_Prowirl200_0x0038_0x03_0x01, 17.08.2015 (Flow, Pr
owirl 200, 0x0038)
HART,
Field Device Manager Version: R430.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_FL_Prowirl200_0x0038_0x02_0x01, 21.08.2019 (Flow, Prowirl 200, 0x0038)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS13_FF_FL_Prowirl200_0x1038_0x02_0x01, 12.11.2018 (Flow, Prowirl 200, 0x1038)
FOUNDATION Fieldbus H1,
AMS Version: 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, Prowirl200_7x2B_HART_FW1_02_zz_Dev_Rev_3, 06.07.2019 (Flow, Prowirl 200, 0x0038)
HART,
DeviceCare Version: 1.06.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00
Plant Resource Manager Version: R3.12Device Type Manager (DTM)1.8.0.431Language neutral -
DTM Single, Prowirl200_7x2B_FF_FW1_00_zz_Dev_Rev_1, 06.07.2019 (Flow, Prowirl 200, 0x1038)
FOUNDATION Fieldbus H1,
DeviceCare Version: 1.06.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00
Plant Resource Manager Version: R3.12Device Type Manager (DTM)1.6.0.72Language neutral -
DTM Single, Prowirl200_7x2B_HART_FW1_01_zz_Dev_Rev_2, 06.07.2019 (Flow, Prowirl 200, 0x0038)
HART,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.2.0.364Language neutral -
DTM Single, Prowirl200_7x2B_7x2C_HART_FW1_03_zz_Dev_Rev_04, 09.07.2019 (Flow, Prowirl 200, 0x0038)
HART,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.06.00
Field Device Manager Version: R450.1
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00
PACTware Version: 5.0
Plant Resource Manager Version: R3.31Device Type Manager (DTM)1.12.0.537Language neutral -
DTM Single, Prowirl200_7x2B_7x2C_FF_FW1_01_zz_Dev_Rev_2, 09.07.2019 (Flow, Prowirl 200, 0x1038)
FOUNDATION Fieldbus H1,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.06.00
Field Device Manager Version: R450.1
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00
PACTware Version: 5.0
Plant Resource Manager Version: R3.31Device Type Manager (DTM)1.11.0.174Language neutral -
DTM Single, Prowirl200_7x2B_7x2C_PA_FW1_01_zz_Dev_Rev_2, 06.07.2019 (Flow, Prowirl 200, 0x1564)
PROFIBUS PA,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.11.0.135Language neutral -
DTM Single, Prowirl200_7x2Bxx_PA_FW1_00_zz_Dev_Rev_1, 06.07.2019 (Flow, Prowirl 200, 0x1564)
PROFIBUS PA,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.1.0.94Language neutral -
DTM Single, Prowirl200_7x2Bxx_HART_FW1_00_zz_Dev_Rev_1, 06.07.2019 (Flow, Prowirl 200, 0x0038)
HART,
DeviceCare Version: 1.06.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00
FieldMate Version: 2.05
Plant Resource Manager Version: R3.10Device Type Manager (DTM)1.0.0.281Language neutral -
Faceplate Library, PRM_HART_Package_Flow_1_08_00, 22.07.2015 (Flow)
HART,
Plant Resource Manager Version: R3.02, R3.05, R3.10, R3.11, R3.12Faceplate1.08.00Language neutral -
Faceplate Library, PRM_FF_Package_Flow_1_05_00, 22.07.2015 (Flow)
FOUNDATION Fieldbus H1,
Plant Resource Manager Version: R3.02, R3.05, R3.10, R3.12Faceplate1.05.00Language neutral -
Faceplate Single, PRM_HART_FL_Prowirl200_0x0038_0x02_0x01, 10.06.2014 (Fl
ow, Prowirl 200, 0x0038)
HART,
Plant Resource Manager Version: R3.11Faceplate1.01.01Language neutral -
Faceplate Single, PRM_FF_FL_Prowirl200_0x1038_0x02_0x01, 28.05.2018 (Flow, Prowirl 200, 0x1038)
FOUNDATION Fieldbus H1,
Plant Resource Manager Version: R3.31Faceplate1.00.00Language neutral -
Faceplate Single, PRM_HART_FL_Prowirl200_0x0038_0x03_0x01, 02.06.2015 (Fl
ow, Prowirl 200, 0x0038)
HART,
Plant Resource Manager Version: R3.12Faceplate1.00.00Language neutral -
Faceplate Single, PRM_FF_FL_Prowirl200_0x1038_0x01_0x01, 22.01.2015 (Flow
, Prowirl 200, 0x1038)
FOUNDATION Fieldbus H1,
Plant Resource Manager Version: R3.12Faceplate1.00.00Language neutral -
Note Single, Release_Notes_Prowirl200_FF_0x1038_0x01, 23.08.2018 (Flow, Prowirl 200, 0x1038)
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: AnyNote1.00.00Language neutral -
Note Single, Release_Notes_for_AMS_HART_Flow, 15.06.2018 (Flow)
HART,
AMS Version: AnyNote1.00.00Language neutral -
Verification DTM Library, VerificationDTM_FLOW_FOUNDATION_Fieldbus, 25.10.2019 (Flow)
FOUNDATION Fieldbus H1,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.03Language neutral -
Verification DTM Library, VerificationDTM_FLOW_HART, 25.10.2019 (Flow)
HART,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.03Language neutral -
Verification DTM Library, VerificationDTM_FLOW_PROFIBUS_PA, 25.10.2019 (Flow)
PROFIBUS PA,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.03Language neutral -
Prowirl D, Prowirl F, Prowirl O, Prowirl R
Product Code: 7R2C-, 7R2B-, 7O2C-, 7O2B-, 7F2C-, 7F2B-, 7D2C-, 7D2B-
Declaration Number: FDA_00113_02.16FDA DeclarationGerman , English -
Prowirl D, Prowirl F, Prowirl O, Prowirl R
Product Code: 7D2B-, 7D2C-, 7F2B-, 7F2C-, 7O2B-, 7O2C-, 7R2B-, 7R2C-
Declaration Number: EC_00309_02.16EU DeclarationGerman , English , fr -
Prowirl D, Prowirl F, Prowirl O, Prowirl R
Product Code: 7D2B-, 7D2C-, 7F2B-, 7F2C-, 7O2B-, 7O2C-, 7R2B-, 7R2C-
Declaration Number: EC_00307_03.16EU DeclarationGerman , English , fr -
Prowirl D, Prowirl F, Prowirl O, Prowirl R
Product Code: 7D2B-, 7D2C-, 7F2B-, 7F2C-, 7O2B-, 7O2C-, 7R2B-, 7R2C-
Declaration Number: EC_00308_02.16EU DeclarationGerman , English , fr -
Prowirl 72, Prowirl 73, Prowirl D, Prowirl F, Prowirl O, Prowirl R
Product Code: 72F-, 72W-, 73F-, 73W-, 7D2B-, 7D2C-, 7F2B-, 7O2B-, 7R2B-
Declaration Number: EC_00057_04.15EU DeclarationGerman , English , fr -
Promass 80, Promass 83, Promass 84, Promass F, Prowirl D, Prowirl F, Prowirl O, Prowirl R
Product Code: 7D2B-, 7F2B-, 7O2B-, 7R2B-, 80F-, 83F-, 83X-, 84F-, 84X-, 8F1B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TС RU C-СH.MU62.B.02588MiscellaneousRussian -
Prowirl D, Prowirl F, Prowirl O, Prowirl R
Product Code: 7D2B-, 7F2B-, 7O2B-, 7R2B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC BY_112 11.01. TP020 003 127MiscellaneousRussian -
Prowirl C, Prowirl D, Prowirl F, Prowirl O, Prowirl R
Product Code: 7C2B-, 7D2B-, 7F2B-, 7O2B-, 7R2B-, O7C2B-, O7D2B-, O7F2B-, O7O2B-, O7R2B-, 7D2C-, 7F2C-, 7O2C-, 7R2C-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/1/A,B,C,D/T6...T1, II,III/1/E,F,G/
Protection: DIP, XP/ISExplosion ProtectionEnglish -
Prowirl R, Prowirl O, Prowirl F, Prowirl D, Prowirl C, Prosonic Flow B, Promass F, Promass E, Promass A, Promag P, Promag H, Promag E
Product Code: O9B2B-, O5P2B-, O5H2B-, 9B2B-, 8F2B-, 8E2C-, 8E2B-, 8A2B-, 7R2C-, 7R2B-, 7O2C-, 7O2B-, 7F2C-, 7F2B-, 7D2C-, 7D2B-, 7C2B-, 5P2B-, 5H2B-, 5E2B-
Region/Country: India
Approval Agency: CC(O)E
Category: zone 1Explosion ProtectionEnglish -
Prowirl F, Prowirl O, Prowirl R, Prowirl D, Prowirl C
Product Code: 7F2C-, 7O2C-, 7D2C-, 7R2C-, 7F2B-, 7R2B-, 7D2B-, 7O2B-, 7C2B-
Region/Country: International (IECEx)
Approval Agency: DEKRA
Protection: Ex ic, Ex ic [ia Ga], Ex ic [ia], Ex nA, Ex nA [ia Ga]Explosion ProtectionEnglish -
Prowirl F, Prowirl O, Prowirl R, Prowirl D, Prowirl C
Product Code: 7F2C-, 7O2C-, 7D2C-, 7R2C-, 7F2B-, 7R2B-, 7D2B-, 7O2B-, 7C2B-
Region/Country: International (IECEx)
Approval Agency: DEKRA
Protection: Ex ia, Ex tbExplosion ProtectionEnglish -
Prowirl F, Prowirl O, Prowirl R, Prowirl D, Prowirl C
Product Code: 7F2C-, 7O2C-, 7D2C-, 7R2C-, 7F2B-, 7R2B-, 7D2B-, 7O2B-, 7C2B-
Region/Country: Europe (ATEX)
Approval Agency: DEKRA
Category: II 3 G, II 1/3 G
Protection: Ex ic [ia Ga], Ex ic [ia], Ex nAExplosion ProtectionEnglish -
Prowirl C, Prowirl D, Prowirl F, Prowirl O, Prowirl R
Product Code: 7R2C-, 7R2B-, 7O2C-, 7O2B-, 7F2C-, 7F2B-, 7D2C-, 7D2B-, 7C2B-
Region/Country: South Africa
Approval Agency: MTEx
Category: zone 2, zone 0,2
Protection: Ex ic, Ex ic [ia Ga], Ex ic [ia], Ex nA, Ex nA [ia Ga], Ex ecExplosion ProtectionEnglish -
Prowirl D, Prowirl F, Prowirl O, Prowirl R, Prowirl C
Product Code: 7F2C-, 7O2C-, 7R2C-, 7D2C-, 7F2B-, 7R2B-, 7D2B-, 7O2B-, 7C2B-, O7R2B-, O7O2B-, O7F2B-, O7D2B-, O7C2B-
Region/Country: China
Approval Agency: NEPSI
Category: zone 1
Protection: Ex d [ia], Ex ia, Ex d [ia Ga]Explosion ProtectionEnglish -
Prowirl F, Prowirl O, Prowirl R, Prowirl D, Prowirl C
Product Code: 7F2B-, 7R2B-, 7D2B-, 7O2B-, 7C2B-
Region/Country: South Korea
Approval Agency: KTL
Category: zone 1, zone 21
Protection: Ex ia, Ex tbExplosion Protection -
Prowirl C, Prowirl D, Prowirl F, Prowirl O, Prowirl R
Product Code: O7R2B-, O7O2B-, O7F2B-, O7D2B-, O7C2B-, 7R2C-, 7R2B-, 7O2C-, 7O2B-, 7F2C-, 7F2B-, 7D2C-, 7D2B-, 7C2B-
Region/Country: China
Approval Agency: NEPSI
Category: zone 2
Protection: Ex ic [ia Ga] IIC T6...T1 Gc, Ex nA IIC T6...T1 Gc, Ex nA [ia Ga] IIC T6...T1 Gc, Ex ic IIC T6...T1 GcExplosion ProtectionEnglish -
Prowirl D, Prowirl F, Prowirl O, Prowirl R
Product Code: 7D2B-, 7F2B-, 7O2B-, 7R2B-
Region/Country: Russia
Approval Agency: EACExplosion ProtectionRussian -
Prowirl D, Prowirl F, Prowirl O, Prowirl R
Product Code: 7R2C-, 7R2B-, 7O2C-, 7O2B-, 7F2C-, 7F2B-, 7D2C-, 7D2B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Protection: Ex tb [ia Da], Ex nA [ia Ga], Ex d [ia Ga], Ex tb, Ex nA, Ex ic [ia Ga], Ex ic, Ex ia, Ex d [ia]Explosion ProtectionRussian -
Prowirl F, Prowirl O, Prowirl R, Prowirl D, Prowirl C
Product Code: 7F2C-, 7R2C-, 7D2C-, 7O2C-, 7F2B-, 7R2B-, 7D2B-, 7O2B-, 7C2B-
Region/Country: Japan
Approval Agency: CML
Protection: Ex d [ia]Explosion ProtectionJapanese -
Prowirl F, Prowirl O, Prowirl R, Prowirl D, Prowirl C
Product Code: 7F2B-, 7R2B-, 7D2B-, 7O2B-, 7C2B-
Region/Country: South Korea
Approval Agency: KTL
Category: zone 1, zone 21
Protection: Ex d [ia], Ex tbExplosion Protection -
Prowirl D, Prowirl F, Prowirl O, Prowirl R, Prowirl C
Product Code: 7F2C-, 7R2C-, 7O2C-, 7D2C-, 7F2B-, 7R2B-, 7D2B-, 7O2B-, 7C2B-
Region/Country: Brazil
Approval Agency: TÜV
Category: zone 0, zone 0,1
Protection: Ex iaExplosion ProtectionPortuguese -
Prowirl C, Prowirl D, Prowirl F, Prowirl O, Prowirl R
Product Code: O7R2B-, O7O2B-, O7F2B-, O7D2B-, O7C2B-, 7R2C-, 7R2B-, 7O2C-, 7O2B-, 7F2C-, 7F2B-, 7D2C-, 7D2B-, 7C2B-
Region/Country: China
Approval Agency: NEPSI
Category: zone 1
Protection: Ex d [ia] IIC T6...T1 Gb, Ex d [ia Ga] IIC T6...T1 Gb, Ex ia IIC T6...T1 GbExplosion ProtectionEnglish -
Prowirl C, Prowirl D, Prowirl F, Prowirl O, Prowirl R
Product Code: 7C2B-, 7D2B-, 7F2B-, 7O2B-, 7R2B-, O7C2B-, O7D2B-, O7F2B-, O7O2B-, O7R2B-, 7D2C-, 7F2C-, 7O2C-, 7R2C-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/2/A,B,C,D/T6...T1, II,III/1/E,F,G/
Protection: DIP, NIExplosion ProtectionEnglish -
Prowirl D, Prowirl F, Prowirl O, Prowirl R, Prowirl C
Product Code: 7F2C-, 7O2C-, 7D2C-, 7R2C-, 7F2B-, 7R2B-, 7D2B-, 7O2B-, 7C2B-
Region/Country: Europe (ATEX)
Approval Agency: DEKRA
Category: II 2 D, II 2 G, II 1/2 G, II 2(1) D
Protection: Ex d [ia], Ex ia, Ex tbExplosion ProtectionEnglish -
Prowirl C, Prowirl D, Prowirl F, Prowirl O, Prowirl R
Product Code: O7R2B-, O7O2B-, O7F2B-, O7D2B-, O7C2B-, 7R2C-, 7R2B-, 7O2B-, 7F2C-, 7F2B-, 7D2C-, 7D2B-, 7C2B-, 7O2C-
Region/Country: China
Approval Agency: NEPSI
Category: zone 0,1
Protection: Ex ia IIC T6...T1 Ga/Gb, Ex d [ia] IIC T6...T1 Gb, Ex d [ia Ga] IIC T6...T1 Gb, Ex iaD 20/21 Txxx°CExplosion ProtectionEnglish -
Prowirl C, Prowirl D, Prowirl F, Prowirl O, Prowirl R
Product Code: 7C2B-, 7D2B-, 7F2B-, 7O2B-, 7R2B-
Region/Country: India
Approval Agency: CC(O)E
Category: zone 1Explosion ProtectionEnglish -
Prowirl D, Prowirl F, Prowirl O, Prowirl R, Prowirl C
Product Code: 7F2C-, 7O2C-, 7D2C-, 7R2C-, 7F2B-, 7R2B-, 7D2B-, 7O2B-, 7C2B-
Region/Country: Europe (ATEX)
Approval Agency: DEKRA
Category: II 2 D, II 2 G, II 1/2 G, II 1 G, II 2(1) D
Protection: Ex ia, Ex d [ia], Ex tb, Ex tb [ia Da]Explosion ProtectionEnglish -
Prowirl C, Prowirl F, Prowirl O, Prowirl R, Prowirl D
Product Code: 7C2B-, 7O2B-, 7F2B-, 7R2B-, 7D2B-
Region/Country: India
Approval Agency: CC(O)E
Category: zone 1
Protection: Ex iaExplosion ProtectionEnglish -
Prowirl C, Prowirl F, Prowirl O, Prowirl R, Prowirl D
Product Code: 7C2B-, 7O2B-, 7F2B-, 7R2B-, 7D2B-
Region/Country: India
Approval Agency: CC(O)E
Category: zone 0,1
Protection: Ex iaExplosion ProtectionEnglish -
Prowirl C, Prowirl D, Prowirl F, Prowirl O, Prowirl R
Product Code: 7C2B-, 7D2B-, 7F2B-, 7O2B-, 7R2B-
Region/Country: South Africa
Approval Agency: SABS
Category: zone 1, zone 2, zone 0, zone 21Explosion ProtectionEnglish -
Prowirl C, Prowirl F, Prowirl O, Prowirl R, Prowirl D
Product Code: 7C2B-, 7O2B-, 7F2B-, 7R2B-, 7D2B-
Region/Country: India
Approval Agency: CC(O)E
Category: zone 0
Protection: Ex iaExplosion ProtectionEnglish -
Prowirl F, Prowirl O, Prowirl R, Prowirl D, Prowirl C
Product Code: 7F2C-, 7O2C-, 7D2C-, 7R2C-, 7F2B-, 7R2B-, 7D2B-, 7O2B-, 7C2B-
Region/Country: International (IECEx)
Approval Agency: DEKRA
Protection: Ex d [ia], Ex tb, Ex tb [ia Da]Explosion ProtectionEnglish -
Prowirl D, Prowirl F, Prowirl O, Prowirl R, Prowirl C
Product Code: 7F2C-, 7O2C-, 7D2C-, 7R2C-, 7F2B-, 7R2B-, 7D2B-, 7O2B-, 7C2B-, O7C2B-, O7D2B-, O7F2B-, O7O2B-, O7R2B-
Region/Country: China
Approval Agency: NEPSI
Category: zone 1, zone 0, zone 20,21
Protection: Ex iaD 20/21 Txxx°C, Ex d [ia], Ex ia, Ex d [ia Ga]Explosion ProtectionEnglish -
Prowirl C, Prowirl D, Prowirl F, Prowirl O, Prowirl R
Product Code: 7R2C-, 7R2B-, 7O2C-, 7O2B-, 7F2C-, 7F2B-, 7D2C-, 7D2B-, 7C2B-
Region/Country: South Africa
Approval Agency: MTEx
Category: zone 1, zone 0, zone 21, zone 0,1
Protection: Ex ia, Ex tb, Ex tb [ia Da]Explosion ProtectionEnglish -
Prowirl C, Prowirl D, Prowirl F, Prowirl O, Prowirl R
Product Code: 7C2B-, 7D2B-, 7F2B-, 7O2B-, 7R2B-, O7C2B-, O7D2B-, O7F2B-, O7O2B-, O7R2B-, 7D2C-, 7F2C-, 7O2C-, 7R2C-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/1/A,B,C,D/T6...T1
Protection: DIP, ISExplosion ProtectionEnglish -
Prowirl D, Prowirl F, Prowirl O, Prowirl R, Prowirl C
Product Code: 7F2C-, 7O2C-, 7R2C-, 7D2C-, 7F2B-, 7R2B-, 7D2B-, 7O2B-, 7C2B-, O7R2B-, O7O2B-, O7F2B-, O7D2B-, O7C2B-
Region/Country: China
Approval Agency: NEPSI
Category: zone 2
Protection: Ex ic, Ex nAExplosion ProtectionEnglish -
Prowirl D, Prowirl F, Prowirl O, Prowirl R, Prowirl C
Product Code: 7F2C-, 7O2C-, 7D2C-, 7R2C-, 7F2B-, 7R2B-, 7D2B-, 7O2B-, 7C2B-
Region/Country: Brazil
Approval Agency: TÜV
Category: zone 2
Protection: Ex nAExplosion ProtectionPortuguese -
Prowirl F, Prowirl O, Prowirl R, Prowirl D
Product Code: 7D2B-, 7O2B-, 7F2B-, 7R2B-
Region/Country: International
Approval Agency: PI, PROFIBUS International
Software Version: PROFIBUS PA PROFILE 3.0.2Fieldbus ConformanceEnglish -
Prowirl C, Prowirl D, Prowirl F, Prowirl O, Prowirl R
Product Code: 7C2B-, 7D2B-, 7F2B-, 7O2B-, 7R2B-
Region/Country: International
Approval Agency: FieldComm Group
Software Version: DEVICE REV. 2, HART 7Fieldbus ConformanceEnglish -
Prowirl F, Prowirl O, Prowirl R, Prowirl D
Product Code: 7D2B-, 7O2B-, 7F2B-, 7R2B-
Region/Country: International
Approval Agency: Fieldbus Foundation
Software Version: DEVICE REV. 1, ITK 6.1.1Fieldbus ConformanceEnglish -
Prowirl C, Prowirl D, Prowirl F, Prowirl O, Prowirl R
Product Code: 7C2B-, 7D2B-, 7D2C-, 7F2B-, 7F2C-, 7O2B-, 7O2C-, 7R2B-, 7R2C-
Region/Country: International
Approval Agency: FieldComm GroupFieldbus ConformanceEnglish -
Prowirl D, Prowirl F, Prowirl O, Prowirl R
Product Code: 7D2B-, 7F2B-, 7O2B-, 7R2B-
Region/Country: Uzbekistan
Approval Agency: UZS
Approval Number: UZS-471MetrologyRussian -
Prowirl F, Prowirl O, Prowirl R, Prowirl D
Product Code: 7R2C-, 7F2B-, 7D2B-, 7O2B-, 7D2C-, 7F2C-, 7O2C-, 7R2B-
Region/Country: Russia
Approval Agency: Rosstandart
Approval Number: OC.C.29.004.A № 56857_1MetrologyRussian -
Prowirl 72, Prowirl 73, Prowirl D, Prowirl F, Prowirl O
Product Code: 72F-, 73W-, 7D2B-, 7F2B-, 7O2B-
Region/Country:
Approval Agency: MSST
Approval Number: MSST_2209MetrologyRussian -
Prowirl C, Prowirl D, Prowirl F, Prowirl O, Prowirl R
Product Code: 7C2B-, 7D2B-, 7F2B-, 7O2B-, 7R2B-
Region/Country: Kazakhstan
Approval Agency: MEMST
Approval Number: GOST-12959MetrologyRussian -
Prowirl D, Prowirl F, Prowirl O, Prowirl R
Product Code: 7D2B-, 7F2B-, 7O2B-, 7R2B-
Approval Number: CH.C.29.004.A_56857ENMetrologyEnglish -
Prowirl D, Prowirl F, Prowirl O, Prowirl R
Product Code: 7D2B-, 7F2B-, 7O2B-, 7R2B-
Region/Country: International
Approval Agency: ABSMarineEnglish -
Prowirl D, Prowirl F, Prowirl O, Prowirl R
Product Code: 7D2B-, 7F2B-, 7O2B-, 7R2B-
Region/Country: International
Approval Agency: RM RSMarineRussian -
Prowirl D, Prowirl F, Prowirl O, Prowirl R
Product Code: 7D2B-, 7F2B-, 7O2B-, 7R2B-
Region/Country: International
Approval Agency: RINAMarineEnglish -
Prowirl D, Prowirl F, Prowirl O, Prowirl R
Product Code: 7D2B-, 7F2B-, 7O2B-, 7R2B-
Region/Country: International
Approval Agency: LRMarineEnglish -
Prowirl F, Prowirl O, Prowirl R, Prowirl D
Product Code: 7F2B-, 7R2B-, 7D2B-, 7O2B-
Region/Country: International
Approval Agency: RM RSMarineRussian -
Prowirl D, Prowirl F, Prowirl O, Prowirl R
Product Code: 7D2B-, 7F2B-, 7O2B-, 7R2B-
Region/Country: International
Approval Agency: BVMarineEnglish -
Prowirl D, Prowirl F, Prowirl O, Prowirl R
Product Code: 7D2B-, 7F2B-, 7O2B-, 7R2B-
Region/Country: International
Approval Agency: DNVGLMarineEnglish
Accessories / Spare parts
-
-
Nr 34 Order code 71108602
I/O module Flow, 2-wr. 2x4-20mA,HART, Ex
Non-Ex, Ex. Current output, 4-20mA HART + 4-20mA analog. Usage: FTM50/FTM51/FTM52. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.
-
Nr 34 Order code 71164940
I/O module, 2-wire, PA/FF, PFS, Ex, V2
Non-Ex, Ex. PROFIBUS PA, FOUNDATION Fieldbus. PFS=switch output. Version 2. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57. Usage: Promass 200, Prowirl 200, Promag 200.
-
-
-
Nr 36 Order code 71222996
Kit pre-amplifier, Prowirl 200
-
-
-
Order code 71128617
Overvoltage protection (OVP10),1-Channel
4-20mA HART. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/ FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Order code 71128619
Overvoltage protection (OVP20),2-Channel
4-20mA HART, PROFIBUS PA, FOUNDATION Fieldbus, Imp./Freq./Switch output. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/ FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Order code 71197334
Transmitter electronics FHX50
Consists of: electronics, ribbon cable. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57. Usage: Promass200, Prowirl 200, Promag 200, Prosonic Flow 200.
-
Order code
Remote display FHX50 please order with separate order structure.
-
Order code 71296840
Plug M12, VA
To connect FHX50. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Not for dust Ex. Usage: Prowirl 200, Promass 200, Promag 200, Prosonic Flow 200.
-
-
-
Nr 30 Order code XPD0011-
-
-
-
Order code 71206552
-
Order code 71206554
-
Order code 71206555
-
-
-
Nr 34 Order code XPD0015-
-
-
-
Order code 71206556
-
-
-
Nr 46 Order code 71222998
Kit cable harness, PW200, compact,remote
-
-
-
Nr 34 Order code XPD0016-
I/O module, 2-wire, 4-20mA,HART, PFS, Ex
Non-Ex, Ex. 1x current output HART. 1x PFS= pulse/freq./switch output.
-
-
-
Nr 46 Order code 71222998
Kit cable harness, PW200, compact,remote
-
-
-
Nr 34 Order code XPD0018-
I/O,2-wire,4-20mA,HART,PFS,4-20mA input
Non-Ex, Ex. 1x current output HART. 1x PFS= pulse/freq./switch output. 1x current input.
-
-
-
Nr 43 Order code 71223001
-
-
-
Nr 44 Order code 71223003
-
-
-
Nr 37 Order code 71110280
Terminal set 2-wire, I/O module
Consists of: 4x terminal 2-pole, green. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Nr 40 Order code XPD0024-
Display module, SD02, push buttons
For housing: GT18, GT19, GT20. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67, FHX50. Promass 200/TB2, Prosonic Flow 200, t-mass 150, Promag 200, Prowirl 200. Consists of: Display SD02, helix cable, ribbon cable, connector cover.
-
Nr 40 Order code XPD0025-
Display module, SD03, Touch Control
For housing: GT18, GT19, GT20. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67, FHX50. Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200. Consists of: Display SD03 illuminated, ribbon cable, connector cover.
-
-
-
Nr 20 Order code 71110281
Cover GT18 316L, HNBR
Material: 316L. O-ring, EPDM, PTFE coated. Usage: FMP51/FMP52/FMP54/FMP55/ FMP56/FMP57, FMR51/FMR52/FMR53/ FMR54/FMR57, FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.
-
Nr 20 Order code 71110282
Cover GT18 316L, sight glass, HNBR
Material: 316L. O-ring NBR, PTFE coated. Usage: FMP51/FMP52/FMP54/FMP55/ FMP56/FMP57, FMR51/FMR52/FMR53/ FMR54/FMR57, FMR62/FMR67, FHX50. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.
-
-
-
Nr 25 Order code 71110291
Cover GT18 316L, terminal Ex, HNBR
Material: 316L. O-ring EPDM, PTFE coated. Usage: terminal compartment, not for Ex d/XP, FMP51/FMP52/FMP54/FMP55/FMP56/FMP57, FMR51/FMR52/FMR53/FMR54/FMR57, FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.
-
Nr 25 Order code 71110284
Cover GT18 316L, terminal Ex d, HNBR
Material: 316L. O-ring EPDM /PTFE coated. Usage: terminal compartment Ex d/XP, FMP51/FMP52/FMP54/FMP55/FMP56/FMP57, FMR51/FMR52/FMR53/FMR54/FMR57, FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.
-
Nr 25 Order code 71185516
Cover GT18 316L, Terminal, OVP, HNBR
Material: 316L. O-ring EPDM, PTFE coated. Usage: terminal compartment, for overvoltage protection, not for Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMP54/FMP56/FMP57, FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Prowirl 200.
-
-
-
Nr 20 Order code 71110299
Cover GT20 Alu, HNBR
Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Nr 20 Order code 71110297
Cover GT20 Alu, sight glass, HNBR
Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Nr 25 Order code 71110301
Cover GT20 Alu, Terminal Ex, HNBR
Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: terminal compartment, not for Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Nr 25 Order code 71110302
Cover GT20 Alu, Terminal Ex d, HNBR
Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: terminal compartment Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Nr 25 Order code 71185517
Cover GT20 Alu, Terminal, OVP, HNBR
Material: aluminium. O-ring EPDM, PTFE coated. Usage: terminal compartment, for overvoltage protection, not for Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Nr 24 Order code 71223005
Kit cover, Alu, remote, sensor
Usage: Prowirl 200. Consists of: 1x cover Alu, 1x O-Ring 75,87x2,62 NBR coated.
-
Nr 24 Order code 71223006
Kit cover,Alu,remote,sensor, -50°C/-58°F
Usage: Prowirl 200. Consists of: 1x cover Alu, 1x O-Ring 75,87x2,62 FVMQ coated.
-
Nr 24 Order code 71223009
Kit cover, 316L, remote, sensor
Usage: Prowirl 200. Consists of: 1x cover 316L, 1x O-Ring 75,87x2,62 NBR coated.
-
Nr 24 Order code 71223011
Kit cover,316L,remote,sensor,-50°C/-58°F
Usage: Prowirl 200. Consists of: 1x cover 316L, 1x O-Ring 75,87x2,62 FVMQ coated.
-
-
-
Nr 65 Order code 71110303
Sealing set GT18/GT19/GT20, EPDM, HNBR
Consists of: O-ring 88.5x3.53 EPDM/PTFE, cover electronics compartment, housing GT19. O-Ring 88.5x3.53 NBR, cover electronics compartment, housing GT18, GT20. O-ring 91.67x3.53 EPDM/PTFE, cover terminal compartment, housing GT19. O-Ring 91.67x3.53 NBR, cover terminal compartment, housing GT18, GT20. O-ring 50.39x3.53 EPDM/PTFE, housing/sensor. FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Nr 73 Order code 71223053
Kit gaskets housing, remote, sensor
Usage: Prowirl 200. Consists of: 1x O-Ring 75,87x2,62 NBR coated for cover. 1x O-Ring 50,39x3,53 HNBR coated for housing/housing support.
-
Nr 73 Order code 71223054
Kit gaskets housing,remote,sensor, -50°C
Usage: Prowirl 200, -50°C/-58°F. Consists of: 1x O-Ring 75.87x2.62 FVMQ for cover. 1x O-Ring 50,39x3,53 FVMQ for housing/housing support.
-
-
-
Nr 15 Order code 50103658
Kit 10 cable glands M20x1,5 grey
-
Nr 15 Order code 50103658
Kit 10 cable glands M20x1,5 grey
-
Nr 15 Order code 50103658
Kit 10 cable glands M20x1,5 grey
-
Nr 15 Order code 50103658
Kit 10 cable glands M20x1,5 grey
-
Nr 15 Order code 50103658
Kit 10 cable glands M20x1,5 grey
-
Nr 15 Order code 50098036
Kit 10 cable glands M20x1.5 Ex
-
Nr 15 Order code 50098036
Kit 10 cable glands M20x1.5 Ex
-
Nr 15 Order code 50098036
Kit 10 cable glands M20x1.5 Ex
-
Nr 15 Order code 50098036
Kit 10 cable glands M20x1.5 Ex
-
Nr 15 Order code 50098036
Kit 10 cable glands M20x1.5 Ex
-
Nr 15 Order code 71069285
Kit 2 cable glands M20x1.5 INOX Ex
-
Nr 15 Order code 71069285
Kit 2 cable glands M20x1.5 INOX Ex
-
Nr 15 Order code 71069285
Kit 2 cable glands M20x1.5 INOX Ex
-
Nr 15 Order code 71069285
Kit 2 cable glands M20x1.5 INOX Ex
-
Nr 15 Order code 71069285
Kit 2 cable glands M20x1.5 INOX Ex
-
Nr 15 Order code 71069285
Kit 2 cable glands M20x1.5 INOX Ex
-
Nr 15 Order code 71120602
Kit 1 cable gl. M20x1.5 armoured, Sensor
-
Nr 15 Order code 71120602
Kit 1 cable gl. M20x1.5 armoured, Sensor
-
Nr 15 Order code 71120602
Kit 1 cable gl. M20x1.5 armoured, Sensor
-
Nr 15 Order code 71120602
Kit 1 cable gl. M20x1.5 armoured, Sensor
-
Nr 15 Order code 71120602
Kit 1 cable gl. M20x1.5 armoured, Sensor
-
Nr 15 Order code 71120602
Kit 1 cable gl. M20x1.5 armoured, Sensor
-
Nr 15 Order code 50098041
Kit 10 ext. M20x1.5/G 1/2" (plug PVC)
-
Nr 15 Order code 50098041
Kit 10 ext. M20x1.5/G 1/2" (plug PVC)
-
Nr 15 Order code 71115505
Kit 10 ext. M20x1,5/G 1/2" (plug brass)
-
Nr 15 Order code 71224905
Kit 2 ext. M20x1.5/G 1/2" INOX Ex
-
Nr 15 Order code 50098042
Kit 10 ext. M20x1.5/NPT 1/2" (plug PVC)
-
Nr 15 Order code 50098042
Kit 10 ext. M20x1.5/NPT 1/2" (plug PVC)
-
Nr 15 Order code 71115509
Kit 10 ext. M20x1,5/NPT1/2"(plug brass)
-
Nr 15 Order code 71224906
Kit 2 ext. M20x1,5/NPT1/2" INOX Ex
-
Nr 15 Order code 50098037
Kit Cable gland Profibus PA
-
Nr 15 Order code 50103658
Kit 10 cable glands M20x1,5 grey
-
Nr 15 Order code 50098037
Kit Cable gland Profibus PA
-
Nr 15 Order code 71069285
Kit 2 cable glands M20x1.5 INOX Ex
-
Nr 15 Order code 50094984
Kit Cable gland Found. Fieldbus
-
Nr 15 Order code 50094984
Kit Cable gland Found. Fieldbus
-
-
-
Nr 19 Order code 71115174
Housing filter 316L, GT18, 1 set
Consists of: 2x filter plug metall 316L. 1x pressure compensation filter. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.
-
Nr 19 Order code 71115175
Housing filter Brass/Ni GT19/20, 1 set
Consists of: 2x filter plug brass nickel, pressure compensation filter. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Nr 17 Order code 71115176
Set housing securing clamps
Usage: housing GT18/GT19/GT20, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Nr 61 Order code 71223056
-
Nr 61 Order code 71223058
-
Nr 61 Order code 71223060
-
Nr 61 Order code 71223062
-
Nr 61 Order code 71223064
-
Nr 61 Order code 71223067
-
Nr 61 Order code 71223069
-
Nr 61 Order code 71223071
-
Nr 61 Order code 71223055
-
Nr 61 Order code 71223056
-
Nr 61 Order code 71223057
-
Nr 61 Order code 71223058
-
Nr 61 Order code 71223059
-
Nr 61 Order code 71223060
-
Nr 61 Order code 71223061
-
Nr 61 Order code 71223062
-
Nr 61 Order code 71223055
-
Nr 61 Order code 71223056
-
Nr 61 Order code 71223057
-
Nr 61 Order code 71223058
-
Nr 61 Order code 71223059
-
Nr 61 Order code 71223060
-
Nr 61 Order code 71223061
-
Nr 61 Order code 71223062
-
Nr 61 Order code 71223063
-
Nr 61 Order code 71223064
-
Nr 61 Order code 71223065
-
Nr 61 Order code 71223067
-
Nr 61 Order code 71223068
-
Nr 61 Order code 71223069
-
Nr 61 Order code 71223070
-
Nr 61 Order code 71223071
-
Nr 61 Order code 71223063
-
Nr 61 Order code 71223064
-
Nr 61 Order code 71223065
-
Nr 61 Order code 71223067
-
Nr 61 Order code 71223068
-
Nr 61 Order code 71223069
-
Nr 61 Order code 71223070
-
Nr 61 Order code 71223071
-
Nr 61 Order code 71223063
-
Nr 61 Order code 71223064
-
Nr 61 Order code 71223065
-
Nr 61 Order code 71223067
-
Nr 61 Order code 71223068
-
Nr 61 Order code 71223069
-
Nr 61 Order code 71223070
-
Nr 61 Order code 71223071
-
Nr 61 Order code 71223073
-
Nr 61 Order code 71223074
-
Nr 61 Order code 71223075
-
-
-
Nr 86 Order code 50106030
Kit 2 Centering rings DN 15 DIN PN 40
-
Nr 86 Order code 50106031
Kit 2 Centering rings DN 15 ANSI150LBS
-
Nr 86 Order code 50106032
Kit 2 Centering rings DN 15 ANSI300LBS
-
Nr 86 Order code 50106033
Kit 2 Centering rings DN 15 JIS 10/20K
-
Nr 86 Order code 50106034
Kit 2 Centering rings DN 25 DIN PN 40
-
Nr 86 Order code 50106035
Kit 2 Centering rings DN 25 ANSI150LBS
-
Nr 86 Order code 50106036
Kit 2 Centering rings DN 25 ANSI300LBS
-
Nr 86 Order code 50106037
Kit 2 Centering rings DN 25 JIS 10/20K
-
Nr 86 Order code 50106038
Kit 2 Centering rings DN 40 DIN PN 40
-
Nr 86 Order code 50106039
Kit 2 Centering rings DN 40 ANSI150LBS
-
Nr 86 Order code 50106040
Kit 2 Centering rings DN 40 ANSI300LBS
-
Nr 86 Order code 50106041
Kit 2 Centering rings DN 40 JIS 10/20K
-
Nr 86 Order code 50106042
Kit 2 Centering rings DN 50 DIN PN 40
-
Nr 86 Order code 50106043
Kit 2 Centering rings DN 50 ANSI150LBS
-
Nr 86 Order code 50106044
Kit 2 Centering rings DN 50 ANSI300LBS
-
Nr 86 Order code 50106045
Kit 2 Centering rings DN 50 JIS 10/20K
-
Nr 86 Order code 50106046
Kit 2 Centering rings DN 80 DIN PN 40
-
Nr 86 Order code 50106047
Kit 2 Centering rings DN 80 ANSI150LBS
-
Nr 86 Order code 50106048
Kit 2 Centering rings DN 80 ANSI300LBS
-
Nr 86 Order code 50106049
Kit 2 Centering rings DN 80 JIS 10K
-
Nr 86 Order code 50106050
Kit 2 Centering rings DN 80 JIS 20K
-
Nr 86 Order code 50106051
Kit 2 Centering rings DN100 DIN PN 16
-
Nr 86 Order code 50106052
Kit 2 Centering rings DN100 DIN PN 40
-
Nr 86 Order code 50106053
Kit 2 Centering rings DN100 ANSI150LBS
-
Nr 86 Order code 50106054
Kit 2 Centering rings DN100 ANSI300LBS
-
Nr 86 Order code 50106055
Kit 2 Centering rings DN100 JIS 10K
-
Nr 86 Order code 50106056
Kit 2 Centering rings DN100 JIS 20K
-
Nr 86 Order code 50106057
Kit 2 Centering rings DN150 DIN PN 16
-
Nr 86 Order code 50106058
Kit 2 Centering rings DN150 DIN PN 40
-
Nr 86 Order code 50106059
Kit 2 Centering rings DN150 ANSI150LBS
-
Nr 86 Order code 50106060
Kit 2 Centering rings DN150 ANSI300LBS
-
Nr 86 Order code 50106061
Kit 2 Centering rings DN150 JIS 10K
-
Nr 86 Order code 50106062
Kit 2 Centering rings DN150 JIS 20K
-
-
-
Order code 71162242
Weather prot. cover GT18/GT19/GT20, 316L
Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/FMR54/ FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Order code 7X2BXX-
-
Order code DK7D-
Prowirl D, mounting set
Mounting set to ensure concentric installation of Disc meter body. Contains threaded bolts, nuts, washers and a pair of flange gaskets.
-
Order code DK7ST-
-
Order code XPRFID-
-
-
Predecessor
-