Title

Try searching by key words, order- or product code or serial number e.g. “CM442” or “Technical information”
Enter at least 2 characters to start the search.

Digital ORP sensor Memosens CPS62E

Memosens 2.0 ORP electrode for the chemical and life sciences industries

Office situation support
Have questions about this product?

Digital ORP sensor Memosens CPS62E

Memosens 2.0 ORP electrode for the chemical and life sciences industries

Get a quote
Office situation support
Have questions about this product?

Benefits

  • Memosens 2.0 offers extended storage of calibration and process data, enabling better trend identification and providing a future-proof basis for predictive maintenance and enhanced IIoT services.
  • Sensor resists strong acids and bases and high organic loads.
  • Maintains high accuracy even after CIP/SIP or autoclaving.
  • Free from animal-based materials and from acrylamide.
  • Upside-down mounting option allows for flexible installation.
  • Maximum process safety is ensured by non-contact, inductive signal transmission.
  • Minimized process downtime and extended sensor lifetime result in reduced operating costs.

Integrated technologies

Memosens technology
Liquiline: cutting-edge transmitter platform
FLEXible answers to individual needs
Current product

Digital ORP sensor Memosens CPS62E

F
L
E
X
  • High-end products
  • Highly functional and convenient

What is FLEX?

FLEX selections
Technical excellence
Simplicity
F
L
E
X
Fundamental selection Meet your basic measurement needs
F
L
E
X
Lean selection Handle your core processes easily
F
L
E
X
Extended selection Optimize your processes with innovative technologies
F
L
E
X
Xpert selection Master your most challenging applications
Variable
Manufacturer's warranty

Engineered for confidence

Our instruments are designed for long‑lasting performance, precise measurement, and dependable operation in demanding industrial environments. Each product includes a standard manufacturer’s warranty that reflects our commitment to quality and to the trust you place in our solutions.

Should a warranty case occur, the device will be assessed and the applicable remedy will be provided in line with the warranty terms – helping ensure a reliable and efficient resolution and supporting continued operation of your measurement point.

Request for extended warranty

If you require extended warranty coverage, simply contact your local Endress+Hauser representative. Our experts will advise you on the available options to match your application and risk profile, helping you protect your investment, reduce unexpected repair costs, and ensure reliable long‑term operation beyond the manufacturer's warranty period.

Learn more

Warranty terms apply

The manufacturer's warranty and extended warranty are subject to specific conditions. For full details, please refer to the locally applicable General Terms and Conditions (GTC), which can be found on the respective country page of our website.

Services by your side

Right‑first‑time commissioning, worldwide

Endress+Hauser’s qualified service engineers ensure your measurement devices are commissioned right the first time, delivering application‑aligned accuracy, regulatory compliance, and operational confidence from startup onwards, anywhere in the world.

Remote support you can trust wherever you operate

With Endress+Hauser Smart Support, you benefit from faster issue resolution, higher uptime, reliable global expertise across the entire product lifecycle – and lasting peace of mind.

Committed to long‑term, sustainable performance

With deep field expertise, harmonized processes, and continuous monitoring, we accompany you with comprehensive service offerings – from initial start‑up through instrumentation maintenance to process optimization – as a true lifetime partner delivering improved outcomes.

For additional information, please contact your local Endress+Hauser representative.

Learn more

24/7 customer portal

Personalized transaction space

Check prices and delivery times, save your favorite products, create quotes and place orders in just a few clicks and track deliveries at any time. With access to your complete order and quote history including all relevant documents you benefit from full transparency throughout the entire process.

Easy access to technical documentation

Select and download all technical documentation such as operating manuals, calibration certificates, approvals and CAD drawings conveniently bundled as a complete documentation package for your entire order or quote.

My Endress+Hauser – all in one place

My Endress+Hauser is your 24/7 connection to Endress+Hauser – in the office, in the field or on the go. It brings together transaction management, documentation and software downloads, knowledge base access, customer support, engineering tools and cloud‑based IIoT services helping you work easier, faster and more efficiently.

Register now / Log in

Technology
Memosens technology

Memosens 2.0: Cutting-edge sensor technology reloaded

Make life easier, increase process safety and stay connected with Memosens 2.0 digital technology.

Technology

Liquiline: cutting-edge transmitter platform

By choosing the Liquiline platform, you’re effectively choosing to spend less money on stock holding, save installation time and gain operational safety!

Product information

Memosens CPS62E - Digital ORP sensor for the chemical and life sciences industries
Memosens CPS62E digital ORP sensor
Specifications
Measuring / Application task ORP / Redox
No results found Try adjusting your search terms to see more results.
Description

Memosens CPS62E is the digital specialist for demanding processes and hygienic applications. Its contamination-resistant gel guarantees stable measurement even in flowing media, in low conductivities and at high temperatures. Thanks to Memosens 2.0 digital technology, CPS62E combines maximum process integrity with simple operation. It resists moisture and enables lab calibration. It offers extended storage of calibration and process data providing the perfect basis for predictive maintenance.

Field of application
  • Process technology and monitoring of processes with: - Quickly changing ORP values - High proportion of electrode poisons such as H2S
  • Chemical processes
  • Hygienic and sterile applications: - Fermenters - Biotechnology - Life sciences

With ATEX, IECEx, CSA C/US, NEPSI, Japan, INMETRO approvals for use in hazardous areas, zones 0, 1 and 2.

Benefits
  • Memosens 2.0 offers extended storage of calibration and process data, enabling better trend identification and providing a future-proof basis for predictive maintenance and enhanced IIoT services.
  • Sensor resists strong acids and bases and high organic loads.
  • Maintains high accuracy even after CIP/SIP or autoclaving.
  • Free from animal-based materials and from acrylamide.
  • Upside-down mounting option allows for flexible installation.
  • Maximum process safety is ensured by non-contact, inductive signal transmission.
  • Minimized process downtime and extended sensor lifetime result in reduced operating costs.
Downloads
Most downloaded
Technical Information (TI)
TI Memosens CPS62E ORP sensor for hygienic and sterile applications
English version - 05/2025
Download
Manufacturer Declaration
Product family: Memosens Product root: CPS12E-, CPS42E-, CPS62E-, CPS72E-, CPS92E-
Declaration number: HE_01505_02.25
Manufacturer specification: RoHS
Additional information: China-RoHS
English version - 09/2025
Download
Operating Instruction (BA)
BA pH sensors CPSx1E, CPFx1E ORP sensors CPSx2E, CPFx2E pH and ORP measurement
English version - 03/2026
Download
The CAD Drawings will be available after the configuration.
All downloads
34 Downloads
Technical Information (TI)
Most downloaded
TI Memosens CPS62E ORP sensor for hygienic and sterile applications
English version - 05/2025
Download
Operating Instruction (BA)
BA pH sensors CPSx1E, CPFx1E ORP sensors CPSx2E, CPFx2E pH and ORP measurement
English version - 03/2026
Download
Ex Safety Instruction (XA)
Memosens pH/ORP sensors pH and ORP measurement
Supplement to BA01988C, BA02142C
Safety instructions for electrical apparatus in explosion-hazardous
areas
UK Ex II 1 G Ex ia IIC T3/T4/T6 Ga
UK Ex II 1G Ex ia IIC T4/T6 Ga
English version - 11/2021
Download
Ex Safety Instruction (XA)
XA Memosens pH/ORP sensors pH and ORP measurement
Supplement to: BA01988C, BA02142C
Safety instructions for electrical apparatus in explosion-hazardous
areas
NEPSI Ex ia IIC T3/T4/T6 Ga
NEPSI Ex ia IIC T4/T6 Ga
English version - 11/2024
Download
Ex Safety Instruction (XA)
Memosens pH/ORP sensors pH and ORP measurement
Supplement to: BA01988C, BA02142C
Safety instructions for electrical apparatus in explosion-hazardous
areas
NEPSI Ex ia IIC T3/T4/T6 Ga
NEPSI Ex ia IIC T4/T6 Ga
English version - 09/2021
Download
Ex Safety Instruction (XA)
XA Memosens pH/ORP sensors pH and ORP measurement
EAC Ex 0Ex ia IIC T3/T4/T6 Ga X
EAC Ex 0Ex ia IIC T4/T6 Ga X
English version - 04/2025
Download
Ex Safety Instruction (XA)
XA Memosens pH/ORP sensors pH and ORP measurement
Supplement to BA01988C, BA02142C
Safety instructions for electrical apparatus for explosion-hazardous areas
ATEX II 1G Ex ia IIC T3/T4/T6 Ga
ATEX II 1G Ex ia IIC T4/T6 Ga
IECEx Ex ia IIC T3/T4/T6 Ga
IECEx Ex ia IIC T4/T6 Ga
English version - 01/2025
Download
Ex Safety Instruction (XA)
XA Memosens pH/ORP sensors pH and ORP measurement
Safety instructions for electrical apparatus in explosion-hazardous
areas
English version - 11/2024
Download
Ex Safety Instruction (XA)
Memosens pH/ORP sensors pH and ORP measurement
Supplement to BA01988C, BA02142C
Safety instructions for electrical apparatus in explosion-hazardous
areas
KOR Ex ia IIC T3/T4/T6 Ga
KOR Ex ia IIC T4/T6 Ga
English version - 10/2021
Download
Ex Safety Instruction (XA)
Memosens pH/ORP sensors pH and ORP measurement
Safety instructions for electrical apparatus in explosion-hazardous
areas
English version - 04/2021
Download
Ex Safety Instruction (XA)
XA Memosens pH/ORP sensors Safety instructions for electrical apparatus in explosion-hazardous areas
CSA C/US IS Cl. I Div. 1 GP A-D T3/T4/T6 + CSA C/US IS Cl. I Zone 0 AEx ia IIC T3/T4/T6
CSA C/US IS Cl. I Div. 1 GP A-D T4/T6 + CSA C/US IS Cl. I Zone 0 AEx ia IIC T4/T6
CSA C/ US Cl. 1 Div 1&2 GP A-D T6…T3
English version - 05/2026
Download
Ex Safety Instruction (XA)
Memosens pH/ORP sensors pH and ORP measurement
Safety instructions for electrical apparatus in explosion-hazardous
areas
English version - 04/2021
Download
Fields of Activities (FA)
Sensors, transmitters, compact devices and assemblies Experts in Liquid Analysis
English version - 02/2026
Download
Fields of Activities (FA)
Sensoren, Messumformer, Kompaktgeräte and Armaturen Kompetenz in der Flüssigkeitsanalyse
German version - 02/2026
Download
Fields of Activities (FA)
Sensori, trasmettitori, dispositivi compatti e armature Sensori, trasmettitori,
dispositivi compatti e armature
Esperti in materia di analisi dei
liquidi
Italian version - 06/2026
Download
Fields of Activities (FA)
Endress+Hauser 水質分析計ファミリ ラインナップと事例
Japanese version - 03/2017
Download
Manufacturer Declaration
Most downloaded
Product family: Memosens Product root: CPS12E-, CPS42E-, CPS62E-, CPS72E-, CPS92E-
Declaration number: HE_01505_02.25
Manufacturer specification: RoHS
Additional information: China-RoHS
English version - 09/2025
Download
EU Declaration
Product family: Memosens Product root: CPS11E-, CPS12E-, CPS16E-, CPS31E-, CPS41E-, CPS42E-, CPS61E-, CPS62E-, CPS71E-, CPS72E-, CPS76E-, CPS91E-, CPS92E-, C
PS96E-
Declaration number: EC_00832_05.26
English version - 06/2026
Download
EU Declaration
Product family: Memosens Product root: CPS11E-, CPS12E-, CPS16E-, CPS31E-, CPS41E-, CPS42E-, CPS61E-, CPS62E-, CPS71E-, CPS72E-, CPS76E-, CPS91E-, CPS92E-, C
PS96E-
Declaration number: EC_00831_03.20
English version - 03/2021
Download
UK Conformity Assessed
Product family: Memocheck, Memosens Product root: CPS11E-, CPS12E-, CPS16E-, CPS31E-, CPS41E-, CPS42E-, CPS61E-, CPS62E-, CPS71E-, CPS72E-, CPS76E-, CPS91E-, CPS92E-,C
PS96E-
Declaration number: UK_00279_02.21
English version - 10/2021
Download
UK Conformity Assessed
Product family: Memosens Product root: CPS11E-, CPS12E-, CPS16E-, CPS31E-, CPS41E-, CPS42E-, CPS61E-, CPS62E-, CPS71E-, CPS72E-, CPS76E-, CPS91E-, CPS92E-, C
PS96E-
Declaration number: UK_00393_01.21
English version - 08/2021
Download
Miscellaneous
Product family: CeraGel, CeraLiquid, Memosens, OrbiSint Product root: CPF82E-, CPS12-, CPS12E-, CPS16E-, CPS42-, CPS42E-, CPS62E-, CPS72-, CPS72E-, CPS76E-, CPS92E-, CPS96E-
Region: Eurasian Economic Union
Approval agency: T-Standard
Approval number: ЕАЭС KZ 7500525.13.12.00642
Russian version - 02/2025
Download
Explosion Protection
Product family: Memocheck, Memosens Product root: CPS11E-, CPS12E-, CPS16E-, CPS31E-, CPS41E-, CPS42E-, CPS47E-, CPS61E-, CPS62E-, CPS71E-, CPS72E-, CPS76E-, CPS77E-, C
PS91E-, CPS92E-, CPS96E-, CPS97E-, CYP02E-
Region: South Korea
Approval agency: KTL
Protection: Ex i Zone 0
Korean version - 09/2021
Download
Explosion Protection
Product family: Memocheck, Memosens Product root: CPS11E-, CPS12E-, CPS16E-, CPS31E-, CPS41E-, CPS42E-, CPS47E-, CPS61E-, CPS62E-, CPS71E-, CPS72E-, CPS76E-, CPS77E-, C
PS91E-, CPS92E-, CPS96E-, CPS97E-, CYP02E-
Region: Brazil
Approval agency: INMETRO
Protection: Ex ia IIC T6 Gb, Ex ia IIC T6...T3 Ga, Ex ia IIC T6...T4 Ga
Portuguese version - 06/2024
Download

Back
Change version
Change version

Spare parts and accessories

further parts
further parts

Kit CPSxx protective caps

further parts
further parts
Order code 71538217

Memoclip label Memosens sensor

Order code 71038228

Memoclip label memosens cable

Order code 71038229

KCL-Electrolyte solution CPY4

Order code CPY4-
Spare parts and accessories
Memosens CPS62E - Digital ORP sensor for the chemical and life sciences industries
Memosens CPS62E digital ORP sensor

Choose from our suggested options

Looking for more options?

Use the extended configuration to configure from all available options.

<%label%>
<%feature%>
-
-
<%feature%>

<%message%>

Configure from all available options Use extended configuration
Order code
Copy
-
-
Add to cart
More actions
Available once configuration is complete
Service not available
Only available on our desktop experience
Configuration details
Memosens CPS62E - Digital ORP sensor for the chemical and life sciences industries
Memosens CPS62E digital ORP sensor
Section ID Selected option

<%feature%>

<%coding%>

<%label%>

CAD Drawings
Configuration support

Unsure about configuration details?

Our experts can help, whatever stage your configuration is at.

Add your product to the cart and request a quote. Whether it is un-configured, partially configured, or fully configured, our experts will contact you to complete the configuration and provide your quote.

Have questions before you start?

Contact us

Spare parts and accessories

further parts
further parts

Kit CPSxx protective caps

further parts
further parts
Order code 71538217

Memoclip label Memosens sensor

Order code 71038228

Memoclip label memosens cable

Order code 71038229

KCL-Electrolyte solution CPY4

Order code CPY4-
Spare parts and accessories