Specs at a glance
-
Accuracy
(Pt100, -50...200 °C) <= 0,1 K
(Pt100, -58...392 °F) <= 0,18 °F
Field of application
Unsurpassed reliability, accuracy and long-term stability in critical processes across all industries. The configurable transmitter transfers converted signals from RTD and thermocouple (TC) temperature probes, as well as resistance and voltage signals using HART® communication. Diagnostics information according to NAMUR NE 107. Seamless integration into all major control and asset management systems. Integrated Bluetooth® interface for remote operation via Endress+Hauser SmartBlue App.
Bluetooth®-enabled temperature transmitter with HART® communication for the conversion of various input signals into a scalable, analog 4 to 20 mA output signal
Improved process efficiency and increased plant uptime
Universal input for RTD, TC, resistance transmitters (Ω), voltage transmitters (mV)
Installation in terminal head form B (flat face) as per DIN EN 50446
Installation in cabinets with DIN rail housing
Optional installation in field housing even for use in Ex d applications
Benefits
-
Safe operation in hazardous areas thanks to international approvals
-
Reliable operation thanks to sensor and device monitoring
-
Integrated Bluetooth® interface for the wireless display of measured values and configuration via E+H SmartBlue (app), optional
-
Diagnostics information according to NAMUR NE 107
-
Available with plug-on display TID10
Optimization of the measurement accuracy by sensor-transmitter matching.
Videos
Lean selection
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity

-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Predecessor
-
-
Technical Information (TI)
iTEMP TMT72
German version - 03/2022
Temperaturtransmitter
EN 18/03/202220/10/202023/04/201903/12/201817/09/2018Language:
German
Version:
18/03/2022
File size:
1.9 MB
File name:
TI01392TDE_0522-00.pdf
-
-
-
Operating Instruction (BA)
iTEMP TMT72
German version - 10/2020
Temperaturtransmitter
EN 16/05/202220/10/202013/05/201903/12/201810/11/2018Language:
German
Version:
20/10/2020
File size:
3.1 MB
File name:
BA01854TDE_0420.pdf
-
-
-
Technical Information (TI)
iTEMP TMT72
Temperature transmitter
EN 18/03/202220/10/202023/04/201903/12/201817/09/2018Language:
English
Version:
18/03/2022
File size:
1.9 MB
File name:
TI01392TEN_0522-00.pdf
-
-
-
Operating Instruction (BA)
iTEMP TMT72
Temperature transmitter
EN 16/05/202220/10/202013/05/201903/12/201810/11/2018Language:
English
Version:
16/05/2022
File size:
3 MB
File name:
BA01854TEN_0522-00.pdf
-
-
-
Short Instruction (KA)
iTEMP TMT71, TMT72
Temperature transmitter TMT71 with 4 to 20 mA analog output TMT72 with HART® communication
EN 29/05/201913/11/2018Language:
English
Version:
29/05/2019
File size:
2 MB
File name:
KA01414TEN_0219.pdf
-
-
-
Ex Safety Instruction (XA)
iTEMP TMT71, TMT72 Control Drawing CSA XP, DIP
Temperature field Transmitter Installation notes for hazardous locations (Explosion proof and Dust ignition proof)
Language:
English
Version:
17/04/2023
File size:
171.8 KB
File name:
10000010390.pdf
-
-
-
Ex Safety Instruction (XA)
iTEMP TMT71, TMT72 Control Drawing CSA Ex ia, Ex ec
Temperature transmitter Installation notes for hazardous locations Intrinsical safety, increased safety
Language:
English
Version:
29/06/2020
File size:
79.4 KB
File name:
10000010382.pdf
-
-
-
Ex Safety Instruction (XA)
iTEMP TMT71, TMT72, TMT82, TMT84, TMT85, TMT86, TMT182B
ATEX: Ex ia IIICTxxx °C Dc, Ex tc IIIC Txxx °C Dc Ex tc IIIC Txxx °C Dc, Ex tc IIIC Dc Ex nA IIC T6 Gc, Ex ec IIC T6 Gc Ex nA IIC Gc, Ex ec IIC Gc
EN 14/11/202215/08/202219/11/201823/03/201605/05/2015Language:
English
Version:
14/11/2022
File size:
446.3 KB
File name:
XA01006TEN_0722-00.pdf
-
-
-
Ex Safety Instruction (XA)
iTEMP TMT71, TMT72
ATEX/IECEx: Ex ia IIC T6 Ga Safety instructions for electrical apparatus in explosion-hazardous areas
EN 16/08/202220/08/202002/03/202030/10/201929/10/2018Language:
English
Version:
16/08/2022
File size:
492.1 KB
File name:
XA01736TEN_0522-00.pdf
-
-
-
Ex Safety Instruction (XA)
iTEMP TMT71, TMT72
Temperature transmitter Ex ia IIC T4...T6 Ga Ex ia IIC T4...T6 Gb Ex ia [ia Ga] IIC T4...T6 Gb Ex ib [ia Ga] IIC T4...T6 Gb
EN 23/12/2022Language:
English
Version:
23/12/2022
File size:
489.9 KB
File name:
XA03097TEN_0122-00.pdf
-
-
-
Ex Safety Instruction (XA)
iTEMP TMT71, TMT72, TMT82, TMT84, TMT85, TMT86
ATEX, IECEx: Ex db IIC T6 Gb Ex tb IIIC Txxx °C Db
EN 20/02/202316/08/202210/11/202001/12/201812/07/2016Language:
English
Version:
20/02/2023
File size:
429.2 KB
File name:
XA01007TEN_0723-00.pdf
-
-
-
Ex Safety Instruction (XA)
iTEMP TMT71, TMT72
Temperature transmitters EAC: 1Ex db IIC T6...T4 Gb X Ex tb IIIC T85°C...T105°C Db X 0Ex ia IIC T6...T4 Ga X
EN 01/08/2021Language:
English
Version:
01/08/2021
File size:
570.4 KB
File name:
XA02657TEN_0121.pdf
-