Title

Try searching by key words, order- or product code or serial number e.g. “CM442” or “Technical information”
Enter at least 2 characters to start the search.

Dosimag electromagnetic flowmeter
New

Flowmeter with hygienic design, highest repeatability, and compact, fully-welded housing

Office situation support
Have questions about this product?

Dosimag electromagnetic flowmeter
New

Flowmeter with hygienic design, highest repeatability, and compact, fully-welded housing

Get a quote

Benefits

  • High and stable filling performance – high measuring accuracy and repeatability in shortest filling times
  • IO-Link allows real-time digital communication for easier commissioning and continuous data availability
  • Compact design for optimized machine footprint
  • Integrated batching functionality – filling process management solved by the flowmeter  
  • Automatic recovery of data for servicing
  • Global compliance with industry standards – EHEDG, 3-A, FCM, cGMP
  • SIP and CIP cleanable

Integrated technologies

IO-Link digital communication technology
FLEXible answers to individual needs
Current product

Dosimag electromagnetic flowmeter

F
L
E
X
  • Specialized products
  • Designed for demanding applications

What is FLEX?

FLEX selections
Technical excellence
Simplicity
F
L
E
X
Fundamental selection Meet your basic measurement needs
F
L
E
X
Lean selection Handle your core processes easily
F
L
E
X
Extended selection Optimize your processes with innovative technologies
F
L
E
X
Xpert selection Master your most challenging applications
Variable
Manufacturer's warranty

Engineered for confidence

Our instruments are designed for long‑lasting performance, precise measurement, and dependable operation in demanding industrial environments. Each product includes a standard manufacturer’s warranty that reflects our commitment to quality and to the trust you place in our solutions.

Should a warranty case occur, the device will be assessed and the applicable remedy will be provided in line with the warranty terms – helping ensure a reliable and efficient resolution and supporting continued operation of your measurement point.

Request for extended warranty

If you require extended warranty coverage, simply contact your local Endress+Hauser representative. Our experts will advise you on the available options to match your application and risk profile, helping you protect your investment, reduce unexpected repair costs, and ensure reliable long‑term operation beyond the manufacturer's warranty period.

Learn more

Warranty terms apply

The manufacturer's warranty and extended warranty are subject to specific conditions. For full details, please refer to the locally applicable General Terms and Conditions (GTC), which can be found on the respective country page of our website.

Services by your side

Right‑first‑time commissioning, worldwide

Endress+Hauser’s qualified service engineers ensure your measurement devices are commissioned right the first time, delivering application‑aligned accuracy, regulatory compliance, and operational confidence from startup onwards, anywhere in the world.

Remote support you can trust wherever you operate

With Endress+Hauser Smart Support, you benefit from faster issue resolution, higher uptime, reliable global expertise across the entire product lifecycle – and lasting peace of mind.

Committed to long‑term, sustainable performance

With deep field expertise, harmonized processes, and continuous monitoring, we accompany you with comprehensive service offerings – from initial start‑up through instrumentation maintenance to process optimization – as a true lifetime partner delivering improved outcomes.

For additional information, please contact your local Endress+Hauser representative.

Learn more

24/7 customer portal

Personalized transaction space

Check prices and delivery times, save your favorite products, create quotes and place orders in just a few clicks and track deliveries at any time. With access to your complete order and quote history including all relevant documents you benefit from full transparency throughout the entire process.

Easy access to technical documentation

Select and download all technical documentation such as operating manuals, calibration certificates, approvals and CAD drawings conveniently bundled as a complete documentation package for your entire order or quote.

My Endress+Hauser – all in one place

My Endress+Hauser is your 24/7 connection to Endress+Hauser – in the office, in the field or on the go. It brings together transaction management, documentation and software downloads, knowledge base access, customer support, engineering tools and cloud‑based IIoT services helping you work easier, faster and more efficiently.

Register now / Log in

Technology
IO-Link digital communication technology

IO-Link communication

IO-Link communication helps to digitalize your plant

Save to list *Saved to list
Office situation support
Have questions about this product?

Product information

Hygienic flowmeter with highest repeatability and fully-welded transmitter for filling and dosing
Dosimag electromagnetic flowmeter
Specifications
Measuring / Application task Liquids
No results found Try adjusting your search terms to see more results.
Description

Dosimag is designed for demanding filling and bottling applications with conductive liquids in Food & Beverage and Life Sciences. In applications where space is limited, Dosimag is the preferred choice for system integrators, skid builders and equipment manufacturers. Dosimag measures volume directly. The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity.

Field of application

The compact and robust sensor is available with three electronics versions:

  • Pulse/frequency/status version for easy and economical use in filling applications
  • Intelligent pulse version with IO-Link provides continuous digital communication, allowing easy commissioning and documentation, real-time availability of process data, optimization of filling conditions and predictive maintenance
  • Integrated batching version with Dynamic Drip Correction over Modbus RTU for advanced filling control
Benefits
  • High and stable filling performance – high measuring accuracy and repeatability in shortest filling times
  • IO-Link allows real-time digital communication for easier commissioning and continuous data availability
  • Compact design for optimized machine footprint
  • Integrated batching functionality – filling process management solved by the flowmeter  
  • Automatic recovery of data for servicing
  • Global compliance with industry standards – EHEDG, 3-A, FCM, cGMP
  • SIP and CIP cleanable
Predecessors
Downloads
Most downloaded
Technical Information (TI)
TI Dosimag Electromagnetic flowmeter
English version - 04/2026
Download
Operating Instruction (BA)
BA Dosimag Electromagnetic flowmeter
English version - 04/2026
Download
Operating Instruction (BA)
BA Dosimag Electromagnetic flowmeter
Modbus RS485
English version - 04/2026
Download
The CAD Drawings will be available after the configuration.
All downloads
40 Downloads
Technical Information (TI)
Most downloaded
TI Dosimag Electromagnetic flowmeter
English version - 04/2026
Download
Operating Instruction (BA)
BA Dosimag Electromagnetic flowmeter
Modbus RS485
English version - 04/2026
Download
Operating Instruction (BA)
Most downloaded
BA Dosimag Electromagnetic flowmeter
English version - 04/2026
Download
Operating Instruction (BA)
BA Dosimag Electromagnetic flowmeter
IO-Link
English version - 04/2026
Download
Device Parameter (GP)
GP Dosimag Electromagnetic flowmeter
IO-Link
English version - 09/2024
Download
Device Parameter (GP)
GP Dosimag Electromagnetic flowmeter
Modbus RS485
English version - 09/2024
Download
Device Parameter (GP)
GP Dosimag Electromagnetic flowmeter
English version - 09/2024
Download
Short Instruction (KA)
KA Dosimag Electromagnetic flowmeter
English version - 03/2026
Download
Installation Instructions (EA)
EA Wall Mounting Set Proline H, Dosimag
English version - 07/2024
Download
Ex Safety Instruction (XA)
XA Dosimag ATEX:
II3G Ex ec IIC T5…T1 Gc
English version - 12/2025
Download
Ex Safety Instruction (XA)
XA Dosimag UL
Class I, Division 2
English version - 12/2025
Download
Ex Safety Instruction (XA)
XA Dosimag UKEX:
II3G
English version - 12/2025
Download
Special Documentation (SD)
SD Endress+Hauser IO-Link devices Endress+Hauser IO-Link device function blocks
For Siemens TIA Portal
English version - 07/2026
Download
Special Documentation (SD)
SD IEC 61406 Automatic identification of physical objects
English version - 02/2025
Download
Special Documentation (SD)
SD Dosimag IO-Link System integration
English version - 10/2024
Download
Special Documentation (SD)
SD Endress+Hauser IO-Link devices Endress+Hauser IO-Link Add-On Instructions
for Rockwell Automation Studio 5000®
English version - 07/2026
Download
Innovation (IN)
一滴も無駄にしない DosimagおよびDosimass – 優れた測定安定性、cGMP適合性、
IO-Linkにより正確な充填と投入を実現
Japanese version - 08/2025
Download
Innovation (IN)
Not a drop to lose Dosimag and Dosimass - precise filling and
dosing with excellent measuring stability,
cGMP compliance and IO-Link
English version - 02/2026
Download
Innovation (IN)
Chaque goutte compte Dosimag et Dosimass – remplissage et dosage précis avec une excellente
stabilité de mesure, conformité cGMP et IO-Link
French version - 01/2025
Download
Innovation (IN)
Keinen Tropfen verlieren Dosimag und Dosimass – präzises Abfüllen
und Dosieren mit hervorragender Messstabilität,
cGMP-Konformität und IO-Link
German version - 02/2026
Download
Manufacturer Declaration
Product family: Dosimag, Dosimag OEM, Ersatzteil, Promag 10, Promag 50, Promag 53, Promag 55, Promag H Product root: 10H-, 50H-, 53H-, 55H-, 5BH-, 5CH-, 5DH-, 5H1B-, 5H2B-, 5H3B-, 5H5B-, 5HBB, 5RH-, 5SH-, D5AB-, DK5G-, DKH-, OD5AB-
Declaration number: HE_01001_07.25
Manufacturer specification: Food hygiene
Additional information: China FCM, China Food Contact Materials, GB4806
English version - 08/2025
Download
Manufacturer Declaration
Product family: Dosimag, Dosimag OEM, Promag H Product root: 5CH-, 5DH-, 5H1B-, 5H2B-, 5H3B-, 5H5B-, 5HBB, 5SH-, D5AB-, O5H1B-, OD5AB-
Declaration number: HE_01917_01.24
Manufacturer specification: Food hygiene
English version - 06/2024
Download
Manufacturer Declaration
Product family: , Dosimag, Dosimag OEM, Ersatzteil, Promag 10, Promag 50, Promag 53, Promag 55, Promag H Product root: 10H-, 50H-, 53H-, 55H-, 5BH-, 5CH-, 5DH-, 5H1B-, 5H2B-, 5H3B-, 5H5B-, 5HBB, 5RH-, 5SH-, D5AB-, DK5G-, DK5HB-, DKH-, O5
H1B-, O5H2B-, OD5AB-, S10H-, S50H-, S53H-, S55H-, S5BH-, S5CH-, S5DH-, S5H1B-, S5H2B-, S5H3B-, S5H5B-, S5HBB-, S5RH-, S5SH-
Declaration number: HE_00404_07.25
Manufacturer specification: Food hygiene, 1935/2004
English version - 12/2024
Download
FDA Declaration
Product family: Dosimag, Dosimag OEM, Ersatzteil, Promag 10, Promag 50, Promag 53, Promag 55, Promag H, Promag P Product root: 53H-, 53P-, 55H-, 55S-, 5BH-, 5CH-, 5DH-, 5H-, 5H1B-, 5H2B-, 5H3B-, 5H5B-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5RH-, 5SH-, D5A
B-, DDA-, DK5G-, DK5HA-, DK5HB-, DKH-, O5H1B-, O5H2B-, O5P1B-, O5P2B-, OD5AB-
Declaration number: FDA_00131_07.25
FDA specification: USP class VI
Additional information: Food hygiene
English version - 12/2025
Download

Back
Change version
Change version

Spare parts and accessories

further parts
further parts

Commubox FXA291 (Hardware)

further parts
further parts
Order code 51516983
Drawing number 3
further parts
further parts

Adapter FXA291 Dosimag/Dosimass packed

further parts
further parts
Order code 71035809
Drawing number 4
further parts
further parts

Connection cable RKWTN8-56/5 P92, 5m

further parts
further parts
Order code 50107895
Drawing number 7

Set adapter M12x1, 8->4pin 4 wire 0.2m

Order code 71703755
Spare parts & accessories
Hygienic flowmeter with highest repeatability and fully-welded transmitter for filling and dosing
Dosimag electromagnetic flowmeter
New

Choose from our suggested options

Looking for more options?

Use the extended configuration to configure from all available options.

<%label%>* (required)
<%feature%>
-
-
<%feature%>

<%message%>

Looking for more options? Use extended configuration
OR
Size and configure based on application parameters Start sizing
Order code
Copy
-
-
Add to cart
More actions
Available once configuration is complete
Service not available
Only available on our desktop experience
Configuration details
Hygienic flowmeter with highest repeatability and fully-welded transmitter for filling and dosing
Dosimag electromagnetic flowmeter
Section ID Selected option

<%feature%>

<%coding%>

<%label%>

CAD Drawings
Configuration support

Unsure about configuration details?

Our experts can help, whatever stage your configuration is at.

Add your product to the cart and request a quote. Whether it is un-configured, partially configured, or fully configured, our experts will contact you to complete the configuration and provide your quote.

Have questions before you start?

Contact us

Spare parts and accessories

further parts
further parts

Commubox FXA291 (Hardware)

further parts
further parts
Order code 51516983
Drawing number 3
further parts
further parts

Adapter FXA291 Dosimag/Dosimass packed

further parts
further parts
Order code 71035809
Drawing number 4
further parts
further parts

Connection cable RKWTN8-56/5 P92, 5m

further parts
further parts
Order code 50107895
Drawing number 7

Set adapter M12x1, 8->4pin 4 wire 0.2m

Order code 71703755
Spare parts & accessories