Capacitance Level measurement Liquicap FMI51

For continuous level and interface measurement in liquids

Office situation support
Have questions about this product?

Capacitance Level measurement Liquicap FMI51

For continuous level and interface measurement in liquids

Get a quote

Benefits

  • Use also in safety systems requiring functional safety to SIL2 in accordance with IEC 61508
  • Reliable and universal application thanks to wide range of certificates and approvals
  • No calibration necessary (factory preconfiguration). No calibration necessary for media with a conductivity of 100μS/cm and higher
  • Material in contact with the process made of corrosion-resistant material, FDA-listed materials
  • Menu-guided local configuration via plain text display (optional)
  • Two-stage overvoltage protection
FLEXible answers to individual needs
Current product

Capacitance Level measurement Liquicap FMI51

F
L
E
X
  • High-end products
  • Highly functional and convenient

What is FLEX?

FLEX selections
Technical excellence
Simplicity
F
L
E
X
Fundamental selection Meet your basic measurement needs
F
L
E
X
Lean selection Handle your core processes easily
F
L
E
X
Extended selection Optimize your processes with innovative technologies
F
L
E
X
Xpert selection Master your most challenging applications
Variable
Manufacturer's warranty

Engineered for confidence

Our instruments are designed for long‑lasting performance, precise measurement, and dependable operation in demanding industrial environments. Each product includes a standard manufacturer’s warranty that reflects our commitment to quality and to the trust you place in our solutions.

Should a warranty case occur, the device will be assessed and the applicable remedy will be provided in line with the warranty terms – helping ensure a reliable and efficient resolution and supporting continued operation of your measurement point.

Request for extended warranty

If you require extended warranty coverage, simply contact your local Endress+Hauser representative. Our experts will advise you on the available options to match your application and risk profile, helping you protect your investment, reduce unexpected repair costs, and ensure reliable long‑term operation beyond the manufacturer's warranty period.

Learn more

Warranty terms apply

The manufacturer's warranty and extended warranty are subject to specific conditions. For full details, please refer to the locally applicable General Terms and Conditions (GTC), which can be found on the respective country page of our website.

Services by your side

Right‑first‑time commissioning, worldwide

Endress+Hauser’s qualified service engineers ensure your measurement devices are commissioned right the first time, delivering application‑aligned accuracy, regulatory compliance, and operational confidence from startup onwards, anywhere in the world.

Remote support you can trust wherever you operate

With Endress+Hauser Smart Support, you benefit from faster issue resolution, higher uptime, reliable global expertise across the entire product lifecycle – and lasting peace of mind.

Committed to long‑term, sustainable performance

With deep field expertise, harmonized processes, and continuous monitoring, we accompany you with comprehensive service offerings – from initial start‑up through instrumentation maintenance to process optimization – as a true lifetime partner delivering improved outcomes.

For additional information, please contact your local Endress+Hauser representative.

Learn more

24/7 customer portal

Personalized transaction space

Check prices and delivery times, save your favorite products, create quotes and place orders in just a few clicks and track deliveries at any time. With access to your complete order and quote history including all relevant documents you benefit from full transparency throughout the entire process.

Easy access to technical documentation

Select and download all technical documentation such as operating manuals, calibration certificates, approvals and CAD drawings conveniently bundled as a complete documentation package for your entire order or quote.

My Endress+Hauser – all in one place

My Endress+Hauser is your 24/7 connection to Endress+Hauser – in the office, in the field or on the go. It brings together transaction management, documentation and software downloads, knowledge base access, customer support, engineering tools and cloud‑based IIoT services helping you work easier, faster and more efficiently.

Register now / Log in

Save to list *Saved to list
Office situation support
Have questions about this product?

Product information

Liquicap FMI51 - Capacitance level measurement
Capacitance - Liquicap FMI51
Specifications
Measuring / Application task Continuous / Liquids
No results found Try adjusting your search terms to see more results.
Description

Liquicap FMI51 is a reliable fully insulated rod probe for continuous level monitoring in liquids, particularly in build-up forming media and extremely high temperatures. The measurement is independent of the dielectric constant (dc). Used in conjunction with Fieldgate FXA320 (remote measured value interrogation using Internet technology), Liquicap is an ideal solution for Inventory Management Solutions.

Field of application

The device is independent of the dielectric constant (dc) as of a liquid conductivity of 100μS/cm and allows measurement of various liquids without the need for recalibration.

  • Process connections: Flanges and threads
  • Process pressure: Vacuum to +100bar (vacuum to +1,450psi)
  • Measuring range: 0.1 to 4.0m (0.3 to 13ft)
  • Temperature: -80 to +200°C (-112 to +392°F)
  • International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approvals
Benefits
  • Use also in safety systems requiring functional safety to SIL2 in accordance with IEC 61508
  • Reliable and universal application thanks to wide range of certificates and approvals
  • No calibration necessary (factory preconfiguration). No calibration necessary for media with a conductivity of 100μS/cm and higher
  • Material in contact with the process made of corrosion-resistant material, FDA-listed materials
  • Menu-guided local configuration via plain text display (optional)
  • Two-stage overvoltage protection
Predecessors
Silometer FMC420, T15393, Float Gauge LTC2230, T6667, T10350, Multicap DC11, Multicap DC16, Double rod probe 11304Z, Multicap T DC12TE, Multicap T DC11TEN, Multicap DC16TEN, Multicap DC11AN, Multicap DC11EN, Multicap DC16AN, Multicap DC16EN, Multicap DC11AS, Multicap DC11ES, Multicap DC16AS, Multicap DC16ES, Multicap T DC11TAS, Multicap DC16TAS, Multicap T DC12TA, Multicap T DC11TAN, Multicap DC16TAN, Multicap T DC11TES, Multicap DC16TES
Downloads
Most downloaded
Technical Information (TI)
TI Liquicap M FMI51 Capacitive
English version - 02/2025
Download
Operating Instruction (BA)
Liquicap M FMI51 PFM Capacitive
English version - 04/2021
Download
Technical Information (TI)
TI Weld-in adapter, process adapter and flanges Level, pressure, temperature
English version - 06/2026
Download
The CAD Drawings will be available after the configuration.
All downloads
125 Downloads
Technical Information (TI)
TI Weld-in adapter, process adapter and flanges Level, pressure, temperature
English version - 06/2026
Download
Technical Information (TI)
Technical Information Liquicap M FMI51, FMI52 Capacitance level measurement
For continuous measurement in liquids
English version - 06/2017
Download
Technical Information (TI)
Most downloaded
TI Liquicap M FMI51 Capacitive
English version - 02/2025
Download
Operating Instruction (BA)
Most downloaded
Liquicap M FMI51 PFM Capacitive
English version - 04/2021
Download
Operating Instruction (BA)
Liquicap M FMI51, FMI52 FEI57C PFM Operating Instructions Capacitance level measurement
Valid as of software version:
FW: V 01.00.00
HW: V 01.00
English version - 06/2017
Download
Operating Instruction (BA)
Operating Instructions Liquicap M FMI51, FMI52 FEI50H HART Capacitive level measurement
English version - 06/2017
Download
Operating Instruction (BA)
Liquicap M FMI51 HART Capacitive Level Measurement
English version - 06/2020
Download
Short Instruction (KA)
Liquicap M FMI51 PFM Capacitive
English version - 08/2021
Download
Short Instruction (KA)
Liquicap M FMI51 HART Capacitive
English version - 08/2021
Download
Installation Instructions (EA)
Cover for housing T13 terminal compartment Installation instruction Liquiphant M/S, Soliphant M, Liquicap M, Solicap M/S
English version - 02/2022
Download
Installation Instructions (EA)
Cover for housing F13 Installation instruction Liquiphant M/S, Soliphant M, Liquicap M, Solicap M/S
English version - 08/2014
Download
Installation Instructions (EA)
Cover for housing T13 electronic compartment Installation instruction Liquiphant M/S, Soliphant M, Liquicap M, Solicap M/S
English version - 08/2014
Download
Installation Instructions (EA)
Cover for housing F27 Installation instruction Liquihant M/S, Soliphant M, Liquicap M, Solicap M/S
English version - 08/2014
Download
Installation Instructions (EA)
Cover for housing T13 electronic compartment with sight glas Installation instruction Liquicap M, Solicap M, Liquphant M/S/FailSafe, Soliphant M
English version - 08/2012
Download
Installation Instructions (EA)
Cable for separate version Installation instruction Liquicap M/ Solicap M (separate version)
English version - 04/2012
Download
Ex Safety Instruction (XA)
XA Liquicap M FMI51, FMI52, FTI51, FTI52 Ex ia IIC T6...T3 Ga/Gb
Ex ia IIC T6...T3 Gb
English version - 05/2023
Download
Ex Safety Instruction (XA)
Liquicap M FMI51, FMI52, FTI51, FTI52 II 1/2 G Ex ia IIC Ga / Ex db IIC Gb
II 1/2 G Ex ia IIC Ga / Ex db eb IIC Gb
II 1/2 D Ex ia IIIC Da / Ex tb IIIC Db
English version - 06/2022
Download
Ex Safety Instruction (XA)
Liquicap M FMI51, FMI52, FTI51, FTI52 II 3 G Ex ec IIC Gc
II 3 G Ex ec nC IIC Gc
II 3 D Ex tc IIIC Dc
English version - 03/2022
Download
Ex Safety Instruction (XA)
Liquicap M FMI51, FMI52, FTI51, FTI52 II 1/2 G Ex ia IIC Ga/Gb
II 1/2 G Ex ia IIB Ga/Gb
II 1/2 D Ex ia IIIC Da/Db
English version - 07/2022
Download
Ex Safety Instruction (XA)
Liquicap M FMI51, FMI52, FTI51, FTI52 CSA Control Drawing
960007471 E
IS, NI
English version - 12/2021
Download
Ex Safety Instruction (XA)
Liquicap M FMI51, FMI52, FTI51, FTI52 Approval No.: IECEx BVS 08.0027X
Ga/Gb Ex ia IIC T6...T3
Zone 20/21 Ex iaD 20/Ex tD A21 IP65 T90°C
English version - 07/2008
Download
Ex Safety Instruction (XA)
XA Liquicap M FMI51, FMI52, FTI51, FTI52 Ex ia IIC T* Ga/Gb
Ex ia IIIC T** °C Da/Db
English version - 06/2026
Download
Ex Safety Instruction (XA)
XA Liquicap M FMI51, FMI52, FTI51, FTI52 ATEX, IECEx:
Ex ia IIC T6 Ga/Gb
Ex ia IIC T6 Gb
Ex ia IIIC Txx°C Da/Db
Ex ia IIIC Txx°C Db
English version - 09/2023
Download
Ex Safety Instruction (XA)
Liquicap M FMI51, FMI52, FTI51, FTI52 II 3 G Ex ec IIC T6 Gc
II 3 G Ex ec nC IIC T5 Gc
II 3 D Ex tc IIIC T100°C Dc
English version - 01/2022
Download

Back
Change version
Change version

Selection of compatible products

/

Spare parts and accessories

Adapter housing/cable entry
Adapter housing/cable entry

Plug 3p M12/M20, gasket

Adapter housing/cable entry
Adapter housing/cable entry
Order code 52005984
Drawing number 15
Cover
Cover

Cover F13 Ex Alu, gasket

Cover
Cover
Order code 52002698
Drawing number 20
Cover
Cover

Cover F17 Alu, gasket

Cover
Cover
Order code 52002699
Drawing number 20
Cover
Cover

Cover T13 Alu, gasket EPDM

Cover
Cover
Order code 52006903
Drawing number 20
Spare parts & accessories
Liquicap FMI51 - Capacitance level measurement
Capacitance - Liquicap FMI51

Choose from our suggested options

Looking for more options?

Use the extended configuration to configure from all available options.

<%label%>
<%feature%>
-
-
<%feature%>

<%message%>

Looking for more options? Use extended configuration
Order code
Copy
-
-
Add to cart
More actions
Available once configuration is complete
Service not available
Only available on our desktop experience
Configuration details
Liquicap FMI51 - Capacitance level measurement
Capacitance - Liquicap FMI51
Section ID Selected option

<%feature%>

<%coding%>

<%label%>

CAD Drawings
Configuration support

Unsure about configuration details?

Our experts can help, whatever stage your configuration is at.

Add your product to the cart and request a quote. Whether it is un-configured, partially configured, or fully configured, our experts will contact you to complete the configuration and provide your quote.

Have questions before you start?

Contact us

Spare parts and accessories

Adapter housing/cable entry
Adapter housing/cable entry

Plug 3p M12/M20, gasket

Adapter housing/cable entry
Adapter housing/cable entry
Order code 52005984
Drawing number 15
Cover
Cover

Cover F13 Ex Alu, gasket

Cover
Cover
Order code 52002698
Drawing number 20
Cover
Cover

Cover F17 Alu, gasket

Cover
Cover
Order code 52002699
Drawing number 20
Cover
Cover

Cover T13 Alu, gasket EPDM

Cover
Cover
Order code 52006903
Drawing number 20
Spare parts & accessories

Selection of compatible products

/