©Endress+Hauser
©Endress+Hauser
Specs at a glance
Measured variables
CH4, CO, CO2, Corg, HCl, H2O, NH3, NO, NO2, N2O, O2, SO2
Ambient temperature range
Field of application
The MCS200HW is a analyzer system for continuous monitoring of up to 10 IR measurement components in flue gases. All parts which touch media are heated above the dew point and therefore protected from corrosion. Internal reference point monitoring allows for a quick check of the measured values without test gases. The web display and the task assistant integrated in the software makes operation very easy. MCS200HW Ex allows reliable emission measurement even in explosion-hazardous areas.
Emission monitoring for waste incineration plants as well as power plants and plants with co-incineration, e.g. cement plants
Measurement of nitrogen oxides in nitric acid plants
Device properties:
Measurement of up to 10 IR components plus O2 and TOC
Wear-free gas distribution through ejector pumps
Reference point monitoring with internal calibration cells
Web server for platform-independent device control
Use of dry test gases for HCl and NH3
Classification for ATEX Zone 2, IIC T3 gb
Benefits
Only one analyzer necessary for simultaneous monitoring of up to 12 gas components
Convenient, task-oriented operation
Remote access without additional software
High availability due to certified internal third-party monitoring (QAL3) without test gases
Data transmission possible via just one interface
Use in explosion-hazardous areas thanks to rugged, pressurized housing
Xpert selection
Specialized products
Designed for demanding applications
Technical excellence
Simplicity
©Endress+Hauser
Simple products
Easy to select, install and operate
Technical excellence
Simplicity
Standard products
Reliable, robust and low-maintenance
Technical excellence
Simplicity
High-end products
Highly functional and convenient
Technical excellence
Simplicity
Specialized products
Designed for demanding applications
Technical excellence
Simplicity
FLEX selections
Technical excellence
Simplicity
Fundamental selection
Meet your basic measurement needs
Technical excellence
Simplicity
Lean selection
Handle your core processes easily
Technical excellence
Simplicity
Extended selection
Optimize your processes with innovative technologies
Technical excellence
Simplicity
Xpert selection
Master your most challenging applications
Technical excellence
Simplicity
Loading alternative products
Success stories
Measuring hydrogen quality in real time
Enapter uses optical analytical measurement technology from Endress+Hauser to determine the purity of hydrogen produced. Find out more!
Read the full story
Measuring principle
Interference filter correlation, Gas filter correlation
Measured variables
CH4, CO, CO2, Corg, HCl, H2O, NH3, NO, NO2, N2O, O2, SO2
Performance-tested measurands
CH4, CO, CO2, Corg, HCl, H2O, NH3, NO, NO2, N2O, O2, SO2
Certified measuring ranges
CH4: 0 ... 50 mg/m³ / 0 ... 500 mg/m³ CO: 0 ... 30 mg/m³ / 0 ... 10,000 mg/m³ CO2: 0 ... 25% by vol. Corg: 0 ... 15 mg/m³ / 0 ... 50 mg/m³ / 0 ... 150 mg/m³ / 0 ... 500 mg/m³ HCl: 0 ... 15 mg/m³ / 0 ... 3,000 mg/m³ H2O: 0 ... 40% by vol. NH3: 0 ... 7 mg/m³ / 0 ... 500 mg/m³ NO: 0 ... 50 mg/m³ / 0 ... 2,500 mg/m³ NO2: 0 ... 50 mg/m³ / 0 ... 500 mg/m³ N2O: 0 ... 45 mg/m³ / 0 ... 2,000 mg/m³ O2: 0 ... 25% by vol. SO2: 0 ... 75 mg/m³ / 0 ... 2,500 mg/m³
Ambient temperature range
Ambient humidity
≤ 90 % Relative humidity; non-condensing
Conformities
Approved for plants requiring approval 2000/76/EC (17. BImSchV) 2001/80/EC (13. BImSchV) 27. BImSchV EN 15267 EN 14181
Hazardous area approvals
MCS200HW Ex: ATEX: II 3G Ex dc ec ic [ic] mc nC pzc IIC T3 Gc Analyzer cabinet II 3G Ex ec IIC T3 Gc Gas sampling unit I 2G Ex eb IIC T Gb Sample gas line IECEx: on request.
Degree of protection
MCS200HW: IP54 MCS200HW Ex: IP65
Most downloaded
MCS200HW
English version - 01/2025
Multicomponent Gas Analyzer
Language:
English
Version:
01/01/2025
File size:
7.9 MB
File name:
8029894_AE00_OI_MCS200HW_en_V3-2_2023-12_EHS.pdf
13 documents
Multicomponent Gas Analyzer, Mounting Plate Version
EN
German
Select other language
01/01/2025
Language:
English
Version:
01/01/2025
File size:
10.4 MB
File name:
8029890_AE00_MCS200HW-MP_en_V1-0_2021-10_EHS.pdf
SFU weatherproof enclosure
Gas Sampling Unit with Weatherproof Enclosure
EN
German
Select other language
01/01/2025
Language:
English
Version:
01/01/2025
File size:
2.6 MB
File name:
8029817_14SF_OI_SFU_IP54_en_V1-1_2019-07_EHS.pdf
EN
Danish German Estonian French Dutch Norwegian Portuguese Russian
Select other language
01/01/2025
Language:
English
Version:
01/01/2025
File size:
2.6 MB
File name:
8029819_YJ80_OI_SFU_IP23_en_V3-0_2015-08_EHS.pdf
Multicomponent Gas Analyzer
EN
German
Select other language
01/01/2025
Language:
English
Version:
01/01/2025
File size:
7.9 MB
File name:
8029894_AE00_OI_MCS200HW_en_V3-2_2023-12_EHS.pdf
MCS200HW and GMS800 FIDOR
MCS200HW & GMS800 FIDOR
EN
German
Select other language
01/01/2025
Language:
English
Version:
01/01/2025
File size:
2.3 MB
File name:
8030592_OI_MCS200HW-FIDOR_en_V2-0_2023-07_EHS.pdf
Multi-Component Gas Analyzer
EN
German
Select other language
01/01/2025
Language:
English
Version:
01/01/2025
File size:
5 MB
File name:
8029892_AE00_MCS200HW_Ex_en_V1-0_2023-08_EHS.pdf
for non-Ex analyzer devices
Language:
English
Version:
01/01/2025
File size:
2.4 MB
File name:
8030257_XA_Safety_Information_non-Ex_ml_V1-0_2016-06_WEB.pdf
EN
German
Select other language
01/01/2025
Language:
English
Version:
01/01/2025
File size:
2.3 MB
File name:
8030732_AE00_SD_MCS200HW_Webdisplay_en_V1-0_2023-04_EHS.pdf
Sample point switching and Master-Redundant-Setting
EN
German
Select other language
01/01/2025
Language:
English
Version:
01/01/2025
File size:
1.3 MB
File name:
8030981_AE00_SD_MCS200HW_sample_point_switch_en_V1-0_2022-02_EHS.pdf
Additional Information for Extractive Gas Analyzers
Language:
English
Version:
01/01/2025
File size:
1.9 MB
File name:
8030255_AE00_SD_EN_61010_Extractive_ml_V1-0_2022-09_EHS.pdf
We value your privacy
We use cookies to enhance your browsing experience, collect statistics to optimize site functionality, and deliver tailored advertisements or content.
By selecting "Accept all", you consent to our use of cookies.
For further details please review our cookie policy .
Customize
Accept only essential
Accept all