Title

Try searching by key words, order- or product code or serial number e.g. “CM442” or “Technical information”
Enter at least 2 characters to start the search.

Raman immersion optic

Unlock the power of in situ laboratory analysis of liquids, slurries, and semi-solids

Office situation support
Have questions about this product?

Raman immersion optic

Unlock the power of in situ laboratory analysis of liquids, slurries, and semi-solids

Get a quote

Benefits

  • Ideal for quick measurements of liquids, slurries, and semi-solids in a laboratory setting
  • Superior signal performance
  • Available in 1/4” and 1/2” diameters
  • No user-adjustable parts
  • Wettable components resist corrosion in harsh environments (including acidic solutions)

Integrated technologies

Raman spectroscopy - advanced optical analysis technology
FLEXible answers to individual needs
Current product

Raman immersion optic

F
L
E
X
  • High-end products
  • Highly functional and convenient

What is FLEX?

FLEX selections
Technical excellence
Simplicity
F
L
E
X
Fundamental selection Meet your basic measurement needs
F
L
E
X
Lean selection Handle your core processes easily
F
L
E
X
Extended selection Optimize your processes with innovative technologies
F
L
E
X
Xpert selection Master your most challenging applications
Variable
Manufacturer's warranty

Engineered for confidence

Our instruments are designed for long‑lasting performance, precise measurement, and dependable operation in demanding industrial environments. Each product includes a standard manufacturer’s warranty that reflects our commitment to quality and to the trust you place in our solutions.

Should a warranty case occur, the device will be assessed and the applicable remedy will be provided in line with the warranty terms – helping ensure a reliable and efficient resolution and supporting continued operation of your measurement point.

Request for extended warranty

If you require extended warranty coverage, simply contact your local Endress+Hauser representative. Our experts will advise you on the available options to match your application and risk profile, helping you protect your investment, reduce unexpected repair costs, and ensure reliable long‑term operation beyond the manufacturer's warranty period.

Learn more

Warranty terms apply

The manufacturer's warranty and extended warranty are subject to specific conditions. For full details, please refer to the locally applicable General Terms and Conditions (GTC), which can be found on the respective country page of our website.

Services by your side

Right‑first‑time commissioning, worldwide

Endress+Hauser’s qualified service engineers ensure your measurement devices are commissioned right the first time, delivering application‑aligned accuracy, regulatory compliance, and operational confidence from startup onwards, anywhere in the world.

Remote support you can trust wherever you operate

With Endress+Hauser Smart Support, you benefit from faster issue resolution, higher uptime, reliable global expertise across the entire product lifecycle – and lasting peace of mind.

Committed to long‑term, sustainable performance

With deep field expertise, harmonized processes, and continuous monitoring, we accompany you with comprehensive service offerings – from initial start‑up through instrumentation maintenance to process optimization – as a true lifetime partner delivering improved outcomes.

For additional information, please contact your local Endress+Hauser representative.

Learn more

24/7 customer portal

Personalized transaction space

Check prices and delivery times, save your favorite products, create quotes and place orders in just a few clicks and track deliveries at any time. With access to your complete order and quote history including all relevant documents you benefit from full transparency throughout the entire process.

Easy access to technical documentation

Select and download all technical documentation such as operating manuals, calibration certificates, approvals and CAD drawings conveniently bundled as a complete documentation package for your entire order or quote.

My Endress+Hauser – all in one place

My Endress+Hauser is your 24/7 connection to Endress+Hauser – in the office, in the field or on the go. It brings together transaction management, documentation and software downloads, knowledge base access, customer support, engineering tools and cloud‑based IIoT services helping you work easier, faster and more efficiently.

Register now / Log in

Technology

Raman spectroscopy - advanced optical analysis technology

Boost plant safety, ensure product quality, and optimize operations. Raman spectroscopy measures the composition and molecular structure of your samples from lab-to-process in real time.

Save to list *Saved to list
Office situation support
Have questions about this product?

Product information

Product picture 1/4" (6.35 mm) and 1/2" (12.7 mm) Raman immersion optics aiming up and left
Raman immersion optics
Specifications
Measuring / Application task Liquids
No results found Try adjusting your search terms to see more results.
Description

The fixed focus design of the Raman immersion optic provides long-term measurement stability along with superior signal performance which is essential for transferable, high-performance Raman measurements. Compatible with the Rxn-10 probe, the immersion optic uses no movable parts so it is always in focus. The Raman immersion optic is well-suited for use in reaction vessels, laboratory reactors, or process streams, and its wettable components resist corrosion in harsh environments.

Field of application
  • Pharmaceutical: drug substance unit operations, reaction analysis, crystallization, end-point detection, solvent swaps
  • Chemical: material identification, reaction analysis, polymerization, cross-linking, blending
  • Food & Beverage: blending, purification, natural and synthetic components
  • Development laboratory: versatile in situ analysis, feasibility studies, model development (or similar)
Benefits
  • Ideal for quick measurements of liquids, slurries, and semi-solids in a laboratory setting
  • Superior signal performance
  • Available in 1/4” and 1/2” diameters
  • No user-adjustable parts
  • Wettable components resist corrosion in harsh environments (including acidic solutions)
Downloads
Most downloaded
Technical Information (TI)
Accessory optics for the Rxn-10 probe Technical Information System design and specifications for Rxn-10 probe optics: Raman
immersion optics (KIO1), non-contact optics (KNCO1),
bIO-Optics (KLBIO1), bio multi optics (KRBMO), bio sleeves
(KRBSL), and Raman optic system for single use (KRSU1)
English version - 07/2026
Download
Technical Information (TI)
Rxn-10 Raman spectroscopic probe Technical Information System design and specifications for the Raman Rxn-10 probe
English version - 09/2025
Download
Operating Instruction (BA)
Accessory optics for the Rxn-10 probe Operating Instructions Commissioning, operation, and maintenance details for Rxn-10
probe optics: Raman immersion optics (KIO1), non-contact
optics (KNCO1), bIO-Optics (KLBIO1), bio multi optic
(KRBMO), bio sleeve (KRBSL), and Raman optic system for
single use (KRSU1)
English version - 06/2026
Download
The CAD Drawings will be available after the configuration.
All downloads
26 Downloads
Technical Information (TI)
Accessory optics for the Rxn-10 probe Technical Information System design and specifications for Rxn-10 probe optics: Raman
immersion optics (KIO1), non-contact optics (KNCO1),
bIO-Optics (KLBIO1), bio multi optics (KRBMO), bio sleeves
(KRBSL), and Raman optic system for single use (KRSU1)
English version - 07/2026
Download
Technical Information (TI)
Rxn-10 Raman spectroscopic probe Technical Information System design and specifications for the Raman Rxn-10 probe
English version - 09/2025
Download
Operating Instruction (BA)
Accessory optics for the Rxn-10 probe Operating Instructions Commissioning, operation, and maintenance details for Rxn-10
probe optics: Raman immersion optics (KIO1), non-contact
optics (KNCO1), bIO-Optics (KLBIO1), bio multi optic
(KRBMO), bio sleeve (KRBSL), and Raman optic system for
single use (KRSU1)
English version - 06/2026
Download
Operating Instruction (BA)
Rxn-10 Raman spectroscopic probe Operating Instructions Commissioning, operation, and maintenance details
for the Raman Rxn-10 probe
English version - 09/2025
Download
Short Instruction (KA)
Rxn-10 Raman spectroscopic probe Brief Operating Instructions Quick start guide for the Raman Rxn-10 probe
English version - 12/2024
Download
Short Instruction (KA)
Accessory Optics for the Rxn-10 Probe Brief Operating Instructions Quick start guide for Rxn-10 probe optics: Raman immersion optics
(KIO1), non-contact optics (KNCO1), bIO-Optics (KLBIO1), bio
multi optics (KRBMO), bio sleeves (KRBSL), and
Raman optic system for single use (KRSU1)
English version - 06/2026
Download
PU (Publication)
Top must-read Biopharma 4.0 articles - Stay informed about the latest research embracing Biopharma 4.0 principles A list of published technical articles related to Biopharma 4.0
topics with recommendations from Life Science industry experts
at Endress+Hauser.
English version - 06/2025
Download
PU (Publication)
Confiance décisionnelle précoce dans la polymérisation Comment la spectroscopie Raman influence
les décisions essentielles tant que des options
sont encore disponibles
French version - 08/2026
Download
PU (Publication)
Accélérer la mise en oeuvre de la spectroscopie dans les procédés chimiques Comment des sites industriels sont passés
du premier signal à la création de valeur opérationnelle,
sans ralentir la production
French version - 08/2026
Download
PU (Publication)
Raman application guide for the life science industry - Trusted composition analysis for the life sciences A guide to our Raman spectroscopy application notes for the
Life Science industry (featuring the Raman Rxn2 analyzer,
Raman Rxn4 analyzer, Rxn-10 probe, Rxn-20 probe, Rxn-45 probe,
Rxn-46 probe, and probe accessory optics (bIO-Optic, Raman single
use optic system / SUB, immersion optic, non-contact optic).
English version - 04/2022
Download
PU (Publication)
Raman-Anwendungsleitfaden für die Life-Sciences-Industrie Ein Leitfaden zu unseren Anwendungshinweisen zur
Raman-Spektroskopie für die Life-Science-Industrie
(Raman Rxn2-Analysator, Raman Rxn4-Analysator,
Rxn-10-Sonde, Rxn-20-Sonde, Rxn-45-Sonde,
Rxn-46-Sonde und Zubehör für Sondenoptiken
(blO-Optic, Raman- Single Use-Optiksystem
/ SUB, Immersionsoptik, berührungslose Optik)
German version - 09/2025
Download
PU (Publication)
Decision-grade confidence in polymerization This brief helps polymerization experts in R&D and production decide
whether Raman spectroscopy can influence real process production
decisions.
English version - 04/2026
Download
PU (Publication)
Earlier decision confidence in polymerization This brief targets polymerization experts and explains how inline
Raman spectroscopy can detect early process deviations and product
grade shifts.
English version - 04/2026
Download
PU (Publication)
The Biopharma 4.0 glossary - Test your Biopharma 4.0 IQ A list of definitions and sources for frequently used terms and
abbreviations in the biopharmaceutical industry related to
Biopharma 4.0.
English version - 06/2025
Download
PU (Publication)
Accelerating Raman spectroscopy implementation in chemical processes This brief shows chemical and polymer teams how to overcome the
technical and organizational barriers that delay Raman deployment.
English version - 04/2026
Download
PU (Publication)
Is your process suitable for Raman spectroscopy today? This checklist shows how experienced chemical plants evaluate
whether Raman spectroscopy supports real operational decisions.
English version - 04/2026
Download
PU (Publication)
Confiance décisionnelle dans la polymérisation Pourquoi les experts en polymérisation peuvent agir
sur les données de spectroscopie Raman
sans perdre le contrôle
French version - 08/2026
Download
PU (Publication)
ライフサイエンス産業向けのラマンアプリケーションガイド -ライフサイエンスのための信頼できる組成分析 ライフサイエンス産業向けラマン分光法アプリケーションノート(
ラマンRxn2アナライザー、ラマンRxn4アナライザー、Rxn-10プロー
ブ、Rxn-20プローブ、Rxn-45プローブ、Rxn-46プローブ、プローブ
オプティックアクセサリ(bIOオプティック、シングルユース向け
ラマンオプティックシステム/SUB、浸漬オプティック、非接触オプ
ティック)。
Japanese version - 08/2024
Download
Competence Brochure (CP)
ラマン分光法食品・飲料アプリケーションガイド - ラボまたはプ ロセス環境における信頼性の高い組成分析技術 本ガイドでは、食品・飲料業界におけるラマン分光法のアプリケー
ションノートについてご紹介しています。Raman Rxn2アナライザ、
Raman Rxn4アナライザ、Rxn-10プローブ、Rxn-20プローブ、Rxn-45
プローブ、ならびに浸漬式オプティックおよび非接触式オプティッ
クを用いた研究事例を取り上げています。
Japanese version - 10/2025
Download
Competence Brochure (CP)
Raman spectroscopy food & beverage application guide - Trusted technology for composition analysis in a laboratory or process environment A guide to Raman spectroscopy application notes for the
food & beverage industry (featuring studies using the
Raman Rxn2 analyzer, Raman Rxn4 analyzer, Rxn-10 probe,
Rxn-20 probe, Rxn-45 probe, and the immersion optic
and non-contact optic).
English version - 02/2022
Download
Innovation (IN)
Raman spectrographic probes - Robust optical measurement of chemical composition An overview brochure about our Raman spectroscopy probe
portfolio including the Rxn-10 probe, Rxn-20 probe, Rxn-30 probe,
Rxn-40 probe, Rxn-41 probe, Rxn-45 probe, Rxn-46 probe, and
probe accessory optics (bIO-Optic, Raman single use optic system /
SUB, immersion optic , non-contact optic), powered by Kaiser Raman
technology.
English version - 10/2021
Download
Innovation (IN)
Raman-Sonden - Zuverlässige optische Analyse der chemischen Zusammensetzung Eine Übersichtsbroschüre über unser Raman-Spektroskopie-Sondenportfolio
einschließlich der Sonden Rxn-10, Rxn-20, Rxn-30,
Rxn-40, Rxn-41, Rxn-45, Rxn-46 und Sonden-Zubehöroptiken
(bIO-Optic, Raman-Singel-Use optiken/SUB,
Immersionsoptik, berührungslose Optik),
die auf der Kaiser Raman-Technologie basiert.
German version - 09/2025
Download
Innovation (IN)
ラマン分光プローブ - 堅牢な分光分析による化学組成分析 ラマン分光法プローブ製品ラインナップに関する概要パンフレット
です。この製品ラインナップには、Rxn-10プローブ、Rxn-20プロー
ブ、Rxn-30プローブ、Rxn-40プローブ、Rxn-41プローブ、Rxn-45プ
ローブ、Rxn-46プローブ、およびプローブオプティクアクセサリ
(bIOオプティック、シングルユース向けラマンオプティックシス
テム/SUB、浸漬オプティック、非接触オプティック)が含まれてい
ます。これらはすべて、Kaiserラマンテクノロジーによって動作し
ます。
Japanese version - 06/2024
Download
White paper (WP)
How Raman ensures product quality from lab-to-process in biopharma A whitepaper about using Raman spectroscopy for lab-to-process
chemical composition measurement in biopharmaceutical manufacturing
(applicable to the Endress+Hauser Raman analyzer and probe
bioprocessing portfolio, powered by Kaiser Raman technology
(including the Raman Rxn2 analyzer, Raman Rxn4 analyzer,
Rxn-10 probe, Rxn-45 probe, Rxn-46 probe, bIO-Optic, Raman
single use optic system, immersion optic , non-contact optic).
English version - 02/2022
Download

Back
Change version
Change version

Selection of compatible products

/

Related content

/
Product picture 1/4" (6.35 mm) and 1/2" (12.7 mm) Raman immersion optics aiming up and left
Raman immersion optics

Choose from our suggested options

Looking for more options?

Use the extended configuration to configure from all available options.

<%label%>
<%feature%>
-
-
<%feature%>

<%message%>

Looking for more options? Use extended configuration
Order code
Copy
-
-
Add to cart
More actions
Available once configuration is complete
Service not available
Only available on our desktop experience
Configuration details
Product picture 1/4" (6.35 mm) and 1/2" (12.7 mm) Raman immersion optics aiming up and left
Raman immersion optics
Section ID Selected option

<%feature%>

<%coding%>

<%label%>

CAD Drawings
Configuration support

Unsure about configuration details?

Our experts can help, whatever stage your configuration is at.

Add your product to the cart and request a quote. Whether it is un-configured, partially configured, or fully configured, our experts will contact you to complete the configuration and provide your quote.

Have questions before you start?

Contact us

Selection of compatible products

/