Specs at a glance
-
Process temperature
Non-contact installation: any
Within installation:
-40°C ... +70°C
(-40°F ... +158°F)
With high temperature adapter:
up to +450°C (+842°F) -
Process pressure / max. overpressure limit
Non-contact installation: any
Within installation:
0.5 bar ... 6.8 bar
(7.2 psi ... 99 psi) abs.
With high pressure adapter:
up to +21 bar (+305 psi) abs. -
Min. density of medium
Solid weight: > 10 g/l
Field of application
The Soliwave microwave barrier uses a non-contact procedure for detection of point levels and bulk flow (flow / no flow, trend). The device is also suitable for detecting and counting objects, detection of deposits as well as monitoring of filling processes and material transfer points. It can be installed in containers, conduits, hoppers, filling stations, shafts, filters or on free fall shafts. It is possible to take a measurement through non-metallic container materials from the outside.
Non-contact (wear- and maintenance-free) limit detection (min/max) and flow monitoring (flow/no flow, trend) for bulk solids.
Detecting, counting and positioning of objects
Detection and analysis of deposits and contamination in filters
Monitoring of filling processes
Monitoring of material transfer points
For high temperature applications up to 450°C (+842°F)
For high pressure applications up to 20bar (+290psi)
International explosion protection certificates
Benefits
Simple assembly with R 1½, 1½ NPT thread or G 1½ (with lock nut)
Mechanically robust construction ensures cost savings over the whole life cycle of the product: No wear and tear, process-wetted ceramic sensor diaphragm (optional), long serviceable life, maintenance free
Mechanically compatible to FQR50/FDR50 and FQR56/FDR56 microwave barrier, existing process connections can be used; likewise, accessories such as adapter flanges, installation brackets and sight glasses can be used again
Increased safety of the point level monitoring by optional integrated bulk flow monitoring
Measuring principle almost independent of the process properties
Can also be used in difficult applications, where other measurement methods fail
Easy operation via the Nivotester FTR525 with graphical display saves time and reduces costs
Extended selection
-
High-end products
- Highly functional and convenient
Technical excellence
Simplicity

-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Predecessor
-
Measuring principle
Microwave barrier
-
Characteristic / Application
Transceiver
Non-contact point level detection and flow monitoring
Detecting, counting and positioning of objects
Monitoring of material transfer points
Detection and analysis of deposits and contamination
Installation:
Non-contact installation (tranmission window) or front-flush installation (contact) -
Specialities
With optional integrated bulk flow monitoring
Parallel mode with up to 5 channels
Detection range limit: max. 100 m
Detection range flow: max. 10 m, depending on bulk solids -
Supply / Communication
Via process transmitter with control unit Nivotester FTR525
-
Ambient temperature
-40 °C...+70 °C
(-40 °F...+158 °F) -
Process temperature
Non-contact installation: any
Within installation:
-40°C ... +70°C
(-40°F ... +158°F)
With high temperature adapter:
up to +450°C (+842°F) -
Process pressure / max. overpressure limit
Non-contact installation: any
Within installation:
0.5 bar ... 6.8 bar
(7.2 psi ... 99 psi) abs.
With high pressure adapter:
up to +21 bar (+305 psi) abs. -
Min. density of medium
Solid weight: > 10 g/l
-
Main wetted parts
Non-contact installation:
no wetted parts
Within installation:
316Ti, PTFE or Ceramic -
Process connection
Threads:
1-1/2" R, 1-1/2" G, 1-1/2" NPT -
Communication
Via process transmitter with control unit Nivotester FTR525
-
Certificates / Approvals
ATEX, CSA C/US, IEC Ex
-
Design approvals
EN10204-3.1
-
Options
Sight glass
High temperature adapter
High pressure adapter
Installation bracket
FAR50, FAR51, FAR52, FAR53, FAR54, FAR55 -
Components
Transmitter: FQR57
Process transmitter: FTR525 -
Application limits
Solid weight: < 10 g/l
Choose from our suggested options
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individual configurator to continue
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Looking for more options? Please use the individual configurator to continue
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD drawings CAD drawings
- CAD drawings
-
Prices per piece
-
<%range%><%price%>
-
- Optional add-ons
Individual configuration
Often bought together
Accessories
Related products