Specs at a glance
-
Max. measurement error
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 180 000 kg/h (0 to 6600 lb/min)
-
Medium temperature range
–50 to +150 °C (–58 to +302 °F)
-
Max. process pressure
PN 100, Class 600, 63K
-
Wetted materials
Measuring tube: Titanium grade 9
Connection: Titanium grade 2
Field of application
The straight single-tube design of the Promass I 100, provides the regular Coriolis flowmeter outputs of mass flow, density and temperature, additionally it provides in-line viscosity measurement as an optional output.
Combined with the smallest transmitter housing available today it delivers full performance on the smallest footprint. Promass I 100 will be the preferred choice for system integrators, skid builders and equipment manufacturers.
Measuring principle operates independently of physical fluid properties such as viscosity or density
Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment.
Device properties
Straight, easy cleanable single-tube system
TMB® technology
Measuring tube made of Titanium
Robust, ultra-compact transmitter housing
High ingress protection: IP69K
Local display available
Benefits
Energy-saving – full bore design enables minimal pressure loss
Fewer process measuring points – multivariable measurement (flow, density, temperature)
Space-saving installation – no in/outlet run needs
Space-saving transmitter – full functionality on smallest footprint
Time-saving local operation without additional software and hardware – integrated web server
Integrated verification – Heartbeat Technology
Videos
Xpert selection
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Predecessor
-
-
Operating Instruction (BA)
Proline Promass I 100
English version - 01/2021
Coriolis flowmeter PROFINET
EN 01/01/202101/12/2015Language:
English
Version:
01/01/2021
File size:
3.4 MB
File name:
BA01429DEN_0221.pdf
-
-
-
Technical Information (TI)
Proline Promass I 100
English version - 01/2021
Coriolis flowmeter
EN 01/01/202101/12/201510/06/201419/09/201301/04/2013Language:
English
Version:
01/01/2021
File size:
3 MB
File name:
TI01035DEN_0621.pdf
-
-
-
Technical Information (TI)
Proline Promass I 100
Coriolis flowmeter
EN 01/01/202101/12/201510/06/201419/09/201301/04/2013Language:
English
Version:
01/01/2021
File size:
3 MB
File name:
TI01035DEN_0621.pdf
-
-
-
Operating Instruction (BA)
Proline Promass I 100
Coriolis flowmeter
Modbus RS485EN 01/01/202101/04/201301/06/2012Language:
English
Version:
01/01/2021
File size:
2.7 MB
File name:
BA01058DEN_0321.pdf
-
-
-
Operating Instruction (BA)
Proline Promass I 100
Coriolis flowmeter
PROFINETEN 01/01/202101/12/2015Language:
English
Version:
01/01/2021
File size:
3.4 MB
File name:
BA01429DEN_0221.pdf
-
-
-
Operating Instruction (BA)
Proline Promass I 100
Coriolis flowmeter
HARTEN 01/01/202110/06/201401/04/2013Language:
English
Version:
01/01/2021
File size:
3 MB
File name:
BA01190DEN_0321.pdf
-
-
-
Operating Instruction (BA)
Proline Promass I 100
Coriolis flowmeter
PROFIBUS DPEN 01/01/202131/12/201419/09/2013Language:
English
Version:
01/01/2021
File size:
3.8 MB
File name:
BA01251DEN_0321.pdf
-
-
-
Operating Instruction (BA)
Proline Promass I 100
Coriolis flowmeter
EtherNet/IPEN 01/01/202131/12/201401/04/201301/06/2012Language:
English
Version:
01/01/2021
File size:
3.6 MB
File name:
BA01066DEN_0421.pdf
-
-
-
Device Parameter (GP)
Proline Promass 100 PROFINET Description of Device Parameters
Coriolis flowmeter
EN 01/10/201701/12/2015Language:
English
Version:
01/10/2017
File size:
1.4 MB
File name:
GP01037DEN_0217.pdf
-
-
-
Device Parameter (GP)
Proline Promass 100 HART Description of Device Parameters
Coriolis flowmeter
EN 01/10/201701/12/2015Language:
English
Version:
01/10/2017
File size:
1.9 MB
File name:
GP01033DEN_0217.pdf
-
-
-
Device Parameter (GP)
Proline Promass 100 PROFIBUS DP Description of Device Parameters
Coriolis flowmeter
EN 01/10/201701/12/2015Language:
English
Version:
01/10/2017
File size:
1.7 MB
File name:
GP01034DEN_0217.pdf
-
-
-
Device Parameter (GP)
Proline Promass 100 EtherNet/IP Description of Device Parameters
Coriolis flowmeter
EN 01/10/201723/12/2015Language:
English
Version:
01/10/2017
File size:
1.5 MB
File name:
GP01036DEN_0217.pdf
-
-
-
Device Parameter (GP)
Proline Promass 100 Modbus RS485 Description of Device Parameters
Coriolis flowmeter
EN 01/10/201723/12/2015Language:
English
Version:
01/10/2017
File size:
1 MB
File name:
GP01035DEN_0217.pdf
-
-
-
Short Instruction (KA)
Proline 100 PROFINET Brief Operating Instructions
Part 2 of 2
TransmitterEN 01/12/2015Language:
English
Version:
01/12/2015
File size:
1.2 MB
File name:
KA01215DEN_0115.pdf
-
-
-
Short Instruction (KA)
Proline 100 Modbus RS485 Brief Operating Instructions
Transmitter with
Coriolis sensorEN 01/10/2017Language:
English
Version:
01/10/2017
File size:
2.4 MB
File name:
KA01335DEN_0117.pdf
-
-
-
Short Instruction (KA)
Proline 100 PROFINET Brief Operating Instructions
Transmitter with
Coriolis sensorEN 01/10/2017Language:
English
Version:
01/10/2017
File size:
1.5 MB
File name:
KA01336DEN_0117.pdf
-
-
-
Short Instruction (KA)
Proline Promass I 100 Brief Operating Instructions
Coriolis flowmeter
EN 14/09/201531/12/201410/06/201419/09/201301/04/2013Language:
English
Version:
14/09/2015
File size:
2.5 MB
File name:
KA01117DEN_0615.pdf
-
-
-
Short Instruction (KA)
Proline Promass Brief Operating Instructions
Proline Promass
Part 1 of 2
Coriolis sensorEN 01/04/201701/08/201601/12/2015Language:
English
Version:
01/04/2017
File size:
833.3 KB
File name:
KA01212DEN_0317.pdf
-
-
-
Short Instruction (KA)
Proline 100 EtherNet/IP Brief Operating Instructions
Transmitter with
Coriolis sensorEN 01/10/2017Language:
English
Version:
01/10/2017
File size:
1.9 MB
File name:
KA01332DEN_0117.pdf
-
-
-
Short Instruction (KA)
Proline 100 PROFIBUS DP Brief Operating Instructions
Transmitter with
Coriolis sensorEN 01/10/2017Language:
English
Version:
01/10/2017
File size:
2.4 MB
File name:
KA01333DEN_0117.pdf
-
-
-
Short Instruction (KA)
Proline 100 HART Brief Operating Instructions
Transmitter with
Coriolis sensorEN 01/10/2017Language:
English
Version:
01/10/2017
File size:
2.3 MB
File name:
KA01334DEN_0117.pdf
-
-
-
Short Instruction (KA)
Flowmeter Proline Promass I
Coriolis sensor
EN 01/08/202201/02/2017Language:
English
Version:
01/08/2022
File size:
773.9 KB
File name:
KA01284DEN_0222-00.pdf
-
-
-
Installation Instructions (EA)
Electrical trace heating systems
Promass 100, 200, 300, 500, 500-digital, LNGmass, CNGmass, LPGmass
EN 01/03/2021Language:
English
Version:
01/03/2021
File size:
883.1 KB
File name:
EA01339DA2_0121.pdf
-
-
-
Installation Instructions (EA)
EA Replacing Small parts
Proline 10, 100, 400, 800 Index C, 500, 500-digital, CNG-, LNG-, LPGmass
EN 01/01/202401/05/202101/04/202131/07/202002/08/2019Language:
English
Version:
01/01/2024
File size:
518.1 KB
File name:
EA01119DA2_0923-00.pdf
-
-
-
Installation Instructions (EA)
Safety Instructions for Spare Parts Installation Instructions
Flowmeter
EN 01/03/201828/11/201325/04/2013Language:
English
Version:
01/03/2018
File size:
139.5 KB
File name:
EA01051DA2_0318.pdf
-
-
-
Installation Instructions (EA)
Replacing Display module, non Ex, Zone 2, Class 1 Div. 2 Installation Instructions
Promass 100, Promag 100, Prosonic Flow E 100
EN 01/12/201708/10/2014Language:
English
Version:
01/12/2017
File size:
340.9 KB
File name:
EA01109DA2_0217.pdf
-
-
-
Installation Instructions (EA)
EA Replacing Spare Parts
CNG-, LNG-, LPGmass, Proline 100, 300, 400 Index C, 500, 500-digital
EN 01/01/202415/12/202101/06/202101/06/202002/08/2019Language:
English
Version:
01/01/2024
File size:
1.9 MB
File name:
EA01018DA2_1523-00.pdf
-
-
-
Installation Instructions (EA)
Activating application packages
Promag 100, 200, 400, Promass 100, 200, Prosonic Flow 100, 200, Prowirl
200, t-mass 150EN 03/03/202015/02/2019Language:
English
Version:
03/03/2020
File size:
406.9 KB
File name:
EA01249DA2_0220.pdf
-
-
-
Ex Safety Instruction (XA)
XA Proline Promass 100
Modbus RS485
EAC:
Zone 1, Zone 0/1, Zone 21EN 01/04/2024Language:
English
Version:
01/04/2024
File size:
628.5 KB
File name:
XA01836DEN_0224-00.pdf
-
-
-
Ex Safety Instruction (XA)
Proline Promass 100 INMETRO: Zone 1 Zone 21 Safety Instructions
Documentation for hazardous area
EN 01/08/201607/11/2014Language:
English
Version:
01/08/2016
File size:
158.7 KB
File name:
XA01219DEN_0216.pdf
-
-
-
Ex Safety Instruction (XA)
Proline Promass 100
ATEX:
II3G
IECEx:
Zone 2EN 15/09/202201/04/201901/08/201601/12/201507/11/2014Language:
English
Version:
15/09/2022
File size:
631 KB
File name:
XA01029DEN_0822-00.pdf
-
-
-
Ex Safety Instruction (XA)
Proline Promass 100
Modbus RS485
ATEX:
II2G, II1/2G
II2D
IECEx:
Zone1, Zone 0/1
Zone 21EN 15/09/202201/04/201901/08/201607/11/201411/04/2013Language:
English
Version:
15/09/2022
File size:
641.9 KB
File name:
XA00159DEN_0622-00.pdf
-
-
-
Ex Safety Instruction (XA)
Proline Promass 100 INMETRO: Zone 2 Safety Instructions
Documentation for hazardous area
EN 01/08/201607/11/2014Language:
English
Version:
01/08/2016
File size:
185.4 KB
File name:
XA01220DEN_0216.pdf
-
-
-
Ex Safety Instruction (XA)
Proline Promass 100 Modbus RS485 NEPSI: Zone 1, Zone 21 Ex i version Safety Instructions
Documentation for hazardous area
EN 05/04/201915/12/201510/11/201401/03/2014Language:
English
Version:
05/04/2019
File size:
295.1 KB
File name:
XA01249DEN_0418.pdf
-
-
-
Ex Safety Instruction (XA)
Proline Promass 100 NEPSI: Zone 2 Ex nA version Safety Instructions
Documentation for hazardous area
EN 05/04/201915/12/201510/11/201422/05/2014Language:
English
Version:
05/04/2019
File size:
293.5 KB
File name:
XA01262DEN_0418.pdf
-
-
-
Ex Safety Instruction (XA)
Proline Promass 100
Modbus RS485
Class I, Divison1; Zone 1 for IS
(Ex i Intrinsically safe version)EN 01/06/202101/05/201707/11/201411/04/201301/07/2012Language:
English
Version:
01/06/2021
File size:
469.5 KB
File name:
XA00160DEN_0521.pdf
-
-
-
Ex Safety Instruction (XA)
XA Proline Promass 100
EAC:
Zone 2EN 01/04/2024Language:
English
Version:
01/04/2024
File size:
620.6 KB
File name:
XA01837DEN_0224-00.pdf
-
-
-
Special Documentation (SD)
Proline Promag/Promass EtherNet/IP
System integration
EN 21/02/2020Language:
English
Version:
21/02/2020
File size:
825.8 KB
File name:
SD02517DEN_0120.pdf
-
-
-
Special Documentation (SD)
UKCA marking
Flow, density, concentration, viscosity
EN 04/11/202201/10/2021Language:
English
Version:
04/11/2022
File size:
357.4 KB
File name:
SD02752DEN_0222-00.pdf
-
-
-
Special Documentation (SD)
SD Promass
EAC Special Documentation
Language:
English
Version:
02/04/2024
File size:
815.6 KB
File name:
SD03241DEN_0124-00.pdf
-
-
-
Special Documentation (SD)
Proline Promass Information on the Pressure Equipment Directive Special Documentation
Coriolis mass flow measuring system
EN 01/06/201201/07/201101/06/2010Language:
English
Version:
01/06/2012
File size:
257.1 KB
File name:
SD00142DEN_1412.pdf
-
-
-
Special Documentation (SD)
Heating jacket For Promass I Coriolis flowmeters Special Documentation
Heating jacket
For Promass I Coriolis flowmetersEN 01/03/2018Language:
English
Version:
01/03/2018
File size:
633.4 KB
File name: