Title

Try searching by key words, order- or product code or serial number e.g. “CM442” or “Technical information”
Enter at least 2 characters to start the search.

Vibronic Point level detection Soliphant FTM52

Robust point level switch with rope extension for fine-grained bulk solids also for hazardous areas

Office situation support
Have questions about this product?

Vibronic Point level detection Soliphant FTM52

Robust point level switch with rope extension for fine-grained bulk solids also for hazardous areas

Get a quote
Office situation support
Have questions about this product?

Benefits

  • SIL2 in accordance with IEC 61508
  • No mechanically moved parts, free of maintenance
  • Measurement not affected by build-up or external vibration
  • Various electronic inserts: e.g. NAMUR, relay, thyristor and PFM-signal outputs for optimum alignment with the plant control system
  • Build-up and abrasion display selectable, density setting and switching delay selectable
  • Choice of coated or polished sensor
  • Build-up and corrosion detection
FLEXible answers to individual needs
Current product

Vibronic Point level detection Soliphant FTM52

F
L
E
X
  • High-end products
  • Highly functional and convenient

What is FLEX?

FLEX selections
Technical excellence
Simplicity
F
L
E
X
Fundamental selection Meet your basic measurement needs
F
L
E
X
Lean selection Handle your core processes easily
F
L
E
X
Extended selection Optimize your processes with innovative technologies
F
L
E
X
Xpert selection Master your most challenging applications
Variable
Manufacturer's warranty

Engineered for confidence

Our instruments are designed for long‑lasting performance, precise measurement, and dependable operation in demanding industrial environments. Each product includes a standard manufacturer’s warranty that reflects our commitment to quality and to the trust you place in our solutions.

Should a warranty case occur, the device will be assessed and the applicable remedy will be provided in line with the warranty terms – helping ensure a reliable and efficient resolution and supporting continued operation of your measurement point.

Request for extended warranty

If you require extended warranty coverage, simply contact your local Endress+Hauser representative. Our experts will advise you on the available options to match your application and risk profile, helping you protect your investment, reduce unexpected repair costs, and ensure reliable long‑term operation beyond the manufacturer's warranty period.

Learn more

Warranty terms apply

The manufacturer's warranty and extended warranty are subject to specific conditions. For full details, please refer to the locally applicable General Terms and Conditions (GTC), which can be found on the respective country page of our website.

Services by your side

Right‑first‑time commissioning, worldwide

Endress+Hauser’s qualified service engineers ensure your measurement devices are commissioned right the first time, delivering application‑aligned accuracy, regulatory compliance, and operational confidence from startup onwards, anywhere in the world.

Remote support you can trust wherever you operate

With Endress+Hauser Smart Support, you benefit from faster issue resolution, higher uptime, reliable global expertise across the entire product lifecycle – and lasting peace of mind.

Committed to long‑term, sustainable performance

With deep field expertise, harmonized processes, and continuous monitoring, we accompany you with comprehensive service offerings – from initial start‑up through instrumentation maintenance to process optimization – as a true lifetime partner delivering improved outcomes.

For additional information, please contact your local Endress+Hauser representative.

Learn more

24/7 customer portal

Personalized transaction space

Check prices and delivery times, save your favorite products, create quotes and place orders in just a few clicks and track deliveries at any time. With access to your complete order and quote history including all relevant documents you benefit from full transparency throughout the entire process.

Easy access to technical documentation

Select and download all technical documentation such as operating manuals, calibration certificates, approvals and CAD drawings conveniently bundled as a complete documentation package for your entire order or quote.

My Endress+Hauser – all in one place

My Endress+Hauser is your 24/7 connection to Endress+Hauser – in the office, in the field or on the go. It brings together transaction management, documentation and software downloads, knowledge base access, customer support, engineering tools and cloud‑based IIoT services helping you work easier, faster and more efficiently.

Register now / Log in

Product information

Soliphant FTM52 - Vibronic point level detection
Vibronic - Soliphant FTM52
Specifications
Measuring / Application task Point Level / Solids
No results found Try adjusting your search terms to see more results.
Description

Soliphant FTM52 is a robust point level switch for use in silos containing fine-grained or powdery solids even with a low bulk density. Suitable for a wide range of applications with international certificates for use in dust or gas hazardous areas. Available with polished fork and stainless steel housing with Tri-Clamp or with aluminum housing and coated fork. Maintenance-free device for use in typical applications like: cereals, flour, cocoa, sugar, animal feed, dye powder, chalk.

Field of application

Point level switch for fine grained solids and powder.

  • Process connections: Threads, flanges and hygienic connection (Tri-Clamp)
  • Temperature: -40 to +80°C (-40 to +170°F)
  • Pressure: -1 to +2bar (-14.5 to +30psi)
  • Sensor length: 750mm to 20,000mm
  • Sensor material: 316L (3,2µm, 0,8µm, PTFE coated)
  • International explosion protection certificates
Benefits
  • SIL2 in accordance with IEC 61508
  • No mechanically moved parts, free of maintenance
  • Measurement not affected by build-up or external vibration
  • Various electronic inserts: e.g. NAMUR, relay, thyristor and PFM-signal outputs for optimum alignment with the plant control system
  • Build-up and abrasion display selectable, density setting and switching delay selectable
  • Choice of coated or polished sensor
  • Build-up and corrosion detection
Predecessors
Soliphant II FTM32, Soliphant II FTM32D, Soliphant II FTM32S, HTM10E, HTM10A, FTM32DR
Downloads
Most downloaded
Technical Information (TI)
Soliphant M FTM52 Vibronic
English version - 05/2021
Download
Technical Information (TI)
Soliphant M FTM50, FTM51, FTM52 Technical Information Universal point level switch for fine-grained bulk solids
Successor documentation for: |
FTM50 = TI01570F | FTM51 = TI01571F | FTM52 = TI01572F
English version - 10/2019
Download
Short Instruction (KA)
Exchange of aluminum housing F17 on Soliphant M FTM50, FTM51, FTM52 Exchange of aluminum housing F17 on Soliphant M FTM50, FTM51, FTM52
English version - 05/2021
Download
The CAD Drawings will be available after the configuration.
All downloads
119 Downloads
Technical Information (TI)
Most downloaded
Soliphant M FTM50, FTM51, FTM52 Technical Information Universal point level switch for fine-grained bulk solids
Successor documentation for: |
FTM50 = TI01570F | FTM51 = TI01571F | FTM52 = TI01572F
English version - 10/2019
Download
Technical Information (TI)
Most downloaded
Soliphant M FTM52 Vibronic
English version - 05/2021
Download
Short Instruction (KA)
Exchange of aluminum housing F17 on Soliphant M FTM50, FTM51, FTM52 Exchange of aluminum housing F17 on Soliphant M FTM50, FTM51, FTM52
English version - 05/2021
Download
Short Instruction (KA)
Exchange of electronic insert on Soliphant M FTM50, FTM51, FTM52 Exchange of electronic insert on Soliphant M FTM50, FTM51, FTM52
English version - 05/2021
Download
Short Instruction (KA)
Soliphant FTM5x Operating instruction Level limit switch for fine-grained bulk solids with separate housing
Instruction for mounting an shortening
English version - 07/2016
Download
Short Instruction (KA)
Soliphant FTM5x Operating Instruction Point Level Switch for fine-grained bulk solids with separate housing
and armored tube.
Instruction for mounting and shortening
English version - 07/2016
Download
Short Instruction (KA)
Soliphant M FTM52 Operating Instructions Rope shortening
English version - 07/2016
Download
Short Instruction (KA)
Soliphant M FTM50, FTM51, FTM52 Point Level Switch for fine-grained bulk solids with separate housing.
Instruction for demounting and mounting of the sensor
English version - 07/2016
Download
Short Instruction (KA)
Soliphant M FTM52 Operating Instruction Universal vibration limit switch for fine-grained bulk solids,
also for explosion-hazardous areas
English version - 01/2018
Download
Short Instruction (KA)
Exchange of sensor on Soliphant M FTM5x - separate version Exchange of sensor on Soliphant M FTM5x - separate version
English version - 04/2012
Download
Short Instruction (KA)
Exchange of Polyester housing F16 on Soliphant M Exchange of Polyester housing F16 on Soliphant M
English version - 05/2021
Download
Short Instruction (KA)
Soliphant M FTM50, FTM51 Operating Instruction Universal vibration limit switch for fine-grained bulk solids,
also for explosion-hazardous areas
English version - 01/2018
Download
Short Instruction (KA)
Exchange of sensor on Soliphant M Exchange of sensor on Soliphant M
English version - 04/2012
Download
Short Instruction (KA)
Mounting the adapter set on Soliphant M FTM50, FTM51, FTM52 Mounting the adapter set on Soliphant M FTM50, FTM51, FTM52
English version - 05/2021
Download
Short Instruction (KA)
Exchange of aluminum housing F13 on Soliphant M FTM50, FTM51, FTM52 Exchange of aluminum housing F13 on Soliphant M FTM50, FTM51, FTM52
English version - 05/2021
Download
Short Instruction (KA)
Exchange of stainless steel housing F15 on Soliphant M FTM50, FTM51, FTM52 Exchange of stainless steel housing F15 on Soliphant M FTM50, FTM51,
FTM52
English version - 05/2021
Download
Installation Instructions (EA)
Cover for housing T13 electronic compartment Installation instruction Liquiphant M/S, Soliphant M, Liquicap M, Solicap M/S
English version - 08/2014
Download
Installation Instructions (EA)
Cover for housing F13 Installation instruction Liquiphant M/S, Soliphant M, Liquicap M, Solicap M/S
English version - 08/2014
Download
Installation Instructions (EA)
Diagnostics plug Installation instruction Liquiphant M/S/FailSafe, Soliphant T/M
English version - 04/2015
Download
Installation Instructions (EA)
Cover for housing F27 Installation instruction Liquihant M/S, Soliphant M, Liquicap M, Solicap M/S
English version - 08/2014
Download
Installation Instructions (EA)
Cover for housing T13 electronic compartment with sight glas Installation instruction Liquicap M, Solicap M, Liquphant M/S/FailSafe, Soliphant M
English version - 08/2012
Download
Installation Instructions (EA)
Cover for Housing F17 Installation instruction LIquiphant M/S/Fail Safe, Soliphant M
English version - 08/2014
Download
Installation Instructions (EA)
Cover for Housing F16 Installation instruction LIquiphant M/S/Fail Safe, Soliphant M
English version - 07/2012
Download
Installation Instructions (EA)
Cover for Housing F15 Installation instruction LIquiphant M/S/Fail Safe, Soliphant M, Cerabar M, Deltapilot M
English version - 08/2014
Download

Back
Change version
Change version

Selection of compatible products

/

Spare parts

Sealing
Sealing

O-ring 26.57x3.53 EPDM, 5 pieces

Sealing
Sealing
Order code 52004276
Drawing number 11
Fixing
Fixing

Adapter set housing/electronics FTM5x

Fixing
Fixing
Order code 52028204
Drawing number 12
Adapter housing/cable entry
Adapter housing/cable entry

Adapter set cable entry NPT1/2

Adapter housing/cable entry
Adapter housing/cable entry
Order code 52004133
Drawing number 15
Adapter housing/cable entry
Adapter housing/cable entry

Adapter set cable gland M20

Adapter housing/cable entry
Adapter housing/cable entry
Order code 52004134
Drawing number 15
Spare parts
Soliphant FTM52 - Vibronic point level detection
Vibronic - Soliphant FTM52

Choose from our suggested options

Looking for more options?

Use the extended configuration to configure from all available options.

<%label%>
<%feature%>
-
-
<%feature%>

<%message%>

Configure from all available options Use extended configuration
Order code
Copy
-
-
Add to cart
More actions
Available once configuration is complete
Service not available
Only available on our desktop experience
Configuration details
Soliphant FTM52 - Vibronic point level detection
Vibronic - Soliphant FTM52
Section ID Selected option

<%feature%>

<%coding%>

<%label%>

CAD Drawings
Configuration support

Unsure about configuration details?

Our experts can help, whatever stage your configuration is at.

Add your product to the cart and request a quote. Whether it is un-configured, partially configured, or fully configured, our experts will contact you to complete the configuration and provide your quote.

Have questions before you start?

Contact us

Spare parts

Sealing
Sealing

O-ring 26.57x3.53 EPDM, 5 pieces

Sealing
Sealing
Order code 52004276
Drawing number 11
Fixing
Fixing

Adapter set housing/electronics FTM5x

Fixing
Fixing
Order code 52028204
Drawing number 12
Adapter housing/cable entry
Adapter housing/cable entry

Adapter set cable entry NPT1/2

Adapter housing/cable entry
Adapter housing/cable entry
Order code 52004133
Drawing number 15
Adapter housing/cable entry
Adapter housing/cable entry

Adapter set cable gland M20

Adapter housing/cable entry
Adapter housing/cable entry
Order code 52004134
Drawing number 15
Spare parts

Selection of compatible products

/