Title

Try searching by key words, order- or product code or serial number e.g. “CM442” or “Technical information”
Enter at least 2 characters to start the search.

TA556 Barstock thermowell

Product is getting phased out

New alternatives available

Phase out policy

Endress+Hauser are committed to the long term support of all our products

We undertake support and service for our products for a period of ten years after notice of product withdrawal (until spareparts are not available any more)

However we reserve us the right to offer alternative solutions including replacement products if deemed more appropriated.

Product status

Product root TA556
Name TA556 Barstock thermowell
Product status In phase out
Phase out date 8/2025
Order stop 12/2027
Spare sensor until not applicable
Calibration until not applicable
Spares available not applicable
Repair until not applicable
New alternative TT151
Maintenance advice

Made of drilled barstock material. Mainly used in heavy duty or general purpose applications.

Office situation support
Have questions about this product?

TA556 Barstock thermowell

Made of drilled barstock material. Mainly used in heavy duty or general purpose applications.

Get a quote

Successors

Benefits

  • The extension and the immersion lengths as well as the bar dimensions can be chosen according to process requirements
  • A wide choice of standard materials and process connections is available; other versions can be ordered according to specification
  • Different grades of surface finishing are also available
  • The thermowell stem shape is stepped
  • The process connection can be threaded or flanged weld
FLEXible answers to individual needs
Current product

TA556 Barstock thermowell

F
L
E
X
  • High-end products
  • Highly functional and convenient

What is FLEX?

FLEX selections
Technical excellence
Simplicity
F
L
E
X
Fundamental selection Meet your basic measurement needs
F
L
E
X
Lean selection Handle your core processes easily
F
L
E
X
Extended selection Optimize your processes with innovative technologies
F
L
E
X
Xpert selection Master your most challenging applications
Variable
Manufacturer's warranty

Engineered for confidence

Our instruments are designed for long‑lasting performance, precise measurement, and dependable operation in demanding industrial environments. Each product includes a standard manufacturer’s warranty that reflects our commitment to quality and to the trust you place in our solutions.

Should a warranty case occur, the device will be assessed and the applicable remedy will be provided in line with the warranty terms – helping ensure a reliable and efficient resolution and supporting continued operation of your measurement point.

Request for extended warranty

If you require extended warranty coverage, simply contact your local Endress+Hauser representative. Our experts will advise you on the available options to match your application and risk profile, helping you protect your investment, reduce unexpected repair costs, and ensure reliable long‑term operation beyond the manufacturer's warranty period.

Learn more

Warranty terms apply

The manufacturer's warranty and extended warranty are subject to specific conditions. For full details, please refer to the locally applicable General Terms and Conditions (GTC), which can be found on the respective country page of our website.

Services by your side

Right‑first‑time commissioning, worldwide

Endress+Hauser’s qualified service engineers ensure your measurement devices are commissioned right the first time, delivering application‑aligned accuracy, regulatory compliance, and operational confidence from startup onwards, anywhere in the world.

Remote support you can trust wherever you operate

With Endress+Hauser Smart Support, you benefit from faster issue resolution, higher uptime, reliable global expertise across the entire product lifecycle – and lasting peace of mind.

Committed to long‑term, sustainable performance

With deep field expertise, harmonized processes, and continuous monitoring, we accompany you with comprehensive service offerings – from initial start‑up through instrumentation maintenance to process optimization – as a true lifetime partner delivering improved outcomes.

For additional information, please contact your local Endress+Hauser representative.

Learn more

24/7 customer portal

Personalized transaction space

Check prices and delivery times, save your favorite products, create quotes and place orders in just a few clicks and track deliveries at any time. With access to your complete order and quote history including all relevant documents you benefit from full transparency throughout the entire process.

Easy access to technical documentation

Select and download all technical documentation such as operating manuals, calibration certificates, approvals and CAD drawings conveniently bundled as a complete documentation package for your entire order or quote.

My Endress+Hauser – all in one place

My Endress+Hauser is your 24/7 connection to Endress+Hauser – in the office, in the field or on the go. It brings together transaction management, documentation and software downloads, knowledge base access, customer support, engineering tools and cloud‑based IIoT services helping you work easier, faster and more efficiently.

Register now / Log in

Save to list *Saved to list
Office situation support
Have questions about this product?

Product information

Product picture barstock thermowell TA556
TA556
Specifications
Measuring / Application task Thermowell
No results found Try adjusting your search terms to see more results.
Description

Due to the challenging process conditions by heavy duty applications the load capacity of a thermowell must be calculated exactly. Dye penetration tests, ultrasound test, helium leakage test, pressure endurance test as well as various, non-destructive material tests prove the quality of materials and processing.

Field of application

TA556 is designed for use with resistance and thermocouple thermometers mainly in heavy duty applications.

Benefits
  • The extension and the immersion lengths as well as the bar dimensions can be chosen according to process requirements
  • A wide choice of standard materials and process connections is available; other versions can be ordered according to specification
  • Different grades of surface finishing are also available
  • The thermowell stem shape is stepped
  • The process connection can be threaded or flanged weld
Downloads
Most downloaded
Technical Information (TI)
Technical Information Omnigrad TA series
Industrial protecting tubes
English version - 09/2005
Download
Technical Information (TI)
Technical information TA556 Industrial protecting tube
omnigrad TA556
Heavy duty - General purpose
From round bar stock - Ø 35 mm
1" NPT threaded or flanged weld type
Also ENI BAR 3 & BAR 4
English version - 05/2001
Download
Operating Instruction (BA)
Thermowells Operating instructions for thermowells for EAC approval
English version - 12/2016
Download
The CAD Drawings will be available after the configuration.
All downloads
12 Downloads
Technical Information (TI)
Technical Information Omnigrad TA series
Industrial protecting tubes
English version - 09/2005
Download
Technical Information (TI)
Technical information TA556 Industrial protecting tube
omnigrad TA556
Heavy duty - General purpose
From round bar stock - Ø 35 mm
1" NPT threaded or flanged weld type
Also ENI BAR 3 & BAR 4
English version - 05/2001
Download
Operating Instruction (BA)
Thermowells Operating instructions for thermowells for EAC approval
English version - 12/2016
Download
Special Documentation (SD)
Device viewer Technical documentation in other languages
English version - 07/2021
Download
Fields of Activities (FA)
Mesure de température Capteurs et transmetteurs de température pour les industries de process
French version - 12/2019
Download
Fields of Activities (FA)
Misura della temperatura Misura della temperatura
Termometri e trasmettitori per l'industria di processo
Italian version - 07/2024
Download
Fields of Activities (FA)
Temperature measurement Thermometers and transmitters for the process industry
English version - 02/2025
Download
Fields of Activities (FA)
Temperaturmesstechnik Thermometer und Transmitter für die Prozessindustrie
German version - 02/2025
Download
Fields of Activities (FA)
温度計 プロセス産業向けの温度計
および伝送器
Japanese version - 02/2020
Download
Fields of Activities (FA)
Misura della temperatura Termometri e trasmettitori per l'industria di processo
Italian version - 02/2020
Download
Fields of Activities (FA)
Catálogo medición temperatura Termómetros y transmisores para la industria de proceso
Spanish version - 04/2018
Download
EU Declaration
Product family: Accessories: Bar stock thermowell, Accessories: Housing, ACCESSORIES: PIPE THERMOWELL, Accessories: RTD insert, ACCESSORIES: TC INSERT, ACCESSORIES: THERMOWELLS, Accessories: Inserts, PLUGS TC DIRECT CONTACT, Terminal head Product root: GPTC-, MLTWS01-, OTA30A-, OTA30D-, OTA30H-, OTW92-,
OTW93-, OTW94-, OTW95-, OTW96-, TA20A-, TA20B-, TA20D-, TA20J-, TA20R-,
TA20W-, TA21E-, TA21H-, TA30A-, TA30D-, TA30H-, TA30P-, TA30R-, TA30S-,
TA414-, TA535-, TA540-, TA541-, TA550-, TA555-, TA556-, TA557-, TA560-,
TA562-, TA565-, TA566-, TA570-, TA571-, TA572-, TA575-, TA576-, TEC300-,
TET300-, TET90-, TPC100-, TPC200-, TPC300-, TPR100-, TPR300-, TS111-,
TT411-, TT511-, TU111-, TU121-, TU211-, TU221-, TU51-, TU52-, TU53-,
TU54-, TU67-, TW10-, TW11-, TW12-, TW13-, TW15-, TW251-, TWF11-, TWF16-
Declaration number: EC_00544_01.17
English version - 05/2017
Download

Back
Change version
Change version

Spare parts and accessories

further parts
further parts

The unit is not repairable

further parts
further parts
Spare parts and accessories
Product picture barstock thermowell TA556
TA556

Choose from our suggested options

Looking for more options?

Use the extended configuration to configure from all available options.

<%label%>
<%feature%>
-
-
<%feature%>

<%message%>

Configure from all available options Use extended configuration
OR
Size and configure based on application parameters Start sizing
Order code
Copy
-
-
Add to cart
More actions
Available once configuration is complete
Service not available
Only available on our desktop experience
Configuration details
Product picture barstock thermowell TA556
TA556
Section ID Selected option

<%feature%>

<%coding%>

<%label%>

CAD Drawings
Configuration support

Unsure about configuration details?

Our experts can help, whatever stage your configuration is at.

Add your product to the cart and request a quote. Whether it is un-configured, partially configured, or fully configured, our experts will contact you to complete the configuration and provide your quote.

Have questions before you start?

Contact us

Spare parts and accessories

further parts
further parts

The unit is not repairable

further parts
further parts
Spare parts and accessories