Proline Promag P 200
Electromagnetic flowmeter
The flowmeter for highest medium temperatures with genuine loop-powered technology
Promag P is dedicated to chemical and process applications with corrosive liquids and high medium temperatures. With genuine loop-powered technology, Promag P 200 enables cost-effective and seamless integration into existing infrastructures. It offers highest operational safety in hazardous areas thanks to its intrinsically safe design (Ex ia). Heartbeat Technology ensures process safety at all times.
- F
- L
- E
- X
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Specs at a glance
-
Max. measurement error
Volume flow: ±0.5 % o.r. ± 2 mm/s (0.08 in/s)
-
Measuring range
4 dm3/min to 1100 m3/h (1 to 4850 gal/min)
-
Medium temperature range
Liner material PFA: –20 to +150 °C (–4 to +302 °F)
Liner material PTFE: –40 to +130 °C (–40 to +266 °F) -
Max. process pressure
PN 40, Class 300, 20K
-
Wetted materials
Liner: PFA; PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum
-
Quick selection
Individual configuration
-
Benefits
Versatile applications – wide variety of wetted materials
Energy-saving flow measurement – no pressure loss due to cross-section constriction
Maintenance-free – no moving parts
Convenient device wiring – separate connection compartment
Safe operation – no...
-
Field of application
The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity
Dedicated to chemical and process applications with corrosive liquids and high medium temperatures
Device properties
Nominal diameter: max....
Documents / Manuals / Software
-
Proline Promag P 200
Technical Information
Electromagnetic flowmeter
Technical Information (TI) -
Proline Promag P 200
PROFIBUS PA
Operating Instructions
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag P 200
HART
Operating Instructions
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag P 200
FOUNDATION Fieldbus
Operating Instructions
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag 200
PROFIBUS PA
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline Promag 200
FOUNDATION Fieldbus
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline Promag 200
HART
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline Promag P
Brief Operating Instructions
Proline Promag P
Electromagnetic sensorShort Instruction (KA)10/17English -
Proline Promag P 200
Brief Operating Instructions
Electromagnetic flowmeter
Short Instruction (KA)09/15English -
Proline Promag
Brief Operating Instructions
Proline Promag
Part 1 of 2
Electromagnetic sensorShort Instruction (KA)04/17English -
Replacing the I/O-Module
Installation Instructions
Promass 200 / TB2, Prosonic Flow 200, Promag 200, Prowirl 200
Installation Instructions (EA) -
Set housing security clamp
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200,Installation Instructions (EA) -
Installing ground disks
Promag 10, 23, 50, 51, 53, 55, 100, 200, 300, 500, 800, 400 Index C
Installation Instructions (EA) -
Replacing the display module
Installation Instructions
Promag 200, Promass 200, Prosonic Flow 200, Prowirl 200, t-mass 150,
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x, Remote dis
play FHX50Installation Instructions (EA) -
Terminal set
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x, Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200,Installation Instructions (EA) -
Replacing the transmitter
Installation Instructions
Promass 200/TB2, Prosonic Flow B 200, Promag 200
Installation Instructions (EA) -
Cover
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200, Remote display FHX50Installation Instructions (EA) -
Sealing set
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200, Remote display FHX50Installation Instructions (EA) -
Replacing the main electronics module
Installation Instructions
Promass 200 / TB2, Prosonic Flow 200, Promag 200
Installation Instructions (EA) -
Bus plug FF
Installation Instructions
Promag 53, 55, Promag 200, Promass 83, Promass 200, Prowirl 72, 73,
Prowirl 200, Prosonic Flow 92, 93Installation Instructions (EA) -
Safety Instructions for Spare Parts
Installation Instructions
Flowmeter
Installation Instructions (EA) -
I/O module
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200,Installation Instructions (EA) -
Activating application packages
Promag 100, 200, 400, Promass 100, 200, Prosonic Flow 100, 200, Prowirl
200, t-mass 150Installation Instructions (EA) -
Housing filter
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200,Installation Instructions (EA) -
Transmitter electronics FHX50
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200,Installation Instructions (EA) -
Proline Promag 200
NEPSI:
Zone 2
Ex nA version
Ex ic version
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Proline Promag 200
INMETRO:
Ex ia IIC T6…T1
Instruções de segurança
Documentação para áreas classificadas
Ex Safety Instructions (XA) -
Proline Promag 200
ATEX: II2G, II2D
IECEx: Zone 1, Zone 21
Ex d version
Safety Instructions
Documentation for hazardous areas
Ex Safety Instructions (XA) -
Proline Promag 200
JPN: Zone 1
Zone 21
Ex d versionEx Safety Instructions (XA) -
Proline Promag 200
NEPSI:
Zone 1, Zone 21
Ex d version
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Proline Promag 200
INMETRO:
Ex d[ia] IIC T6…T1
Instruções de segurança
Documentação para áreas classificadas
Ex Safety Instructions (XA) -
Proline Promag 200
INMETRO:
Ex nA IIC T6…T1
Instruções de segurança
Documentação para áreas classificadas
Ex Safety Instructions (XA) -
Proline Promag 200
ATEX: II2G, II2D
IECEx: Zone 1, Zone 21
Ex i version
Safety Instructions
Documentation for hazardous areas
Ex Safety Instructions (XA) -
Proline Promag 200
NEPSI:
Zone 1, Zone 21
Ex i version
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Proline Promag 200
Cl. I, II, III Div. 1, Zone 1 for XP
(Ex d Flameproofed version)
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Proline Promag 200
ATEX: II3G
IECEx: Zone 2
Safety Instructions
Documentation for hazardous areas
Ex Safety Instructions (XA) -
Proline Promag 200
Cl. I, II, III Div. 1 for IS
(Ex i Intrinsically safe version)
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Information on the Pressure Equipment Directive
Proline flowmeters
Special Documentation
Proline flowmeters
Special Documentation (SD) -
Proline Promag 200
Functional Safety Manual
Special Documentation
Electromagnetic flowmeter
Special Documentation (SD) -
Proline Promag 200
Heartbeat Verification application package
Special Documentation
Electromagnetic flowmeter
Special Documentation (SD) -
Change of Directives
Special Documentation
Change of Directives
Special Documentation (SD) -
Technical Documentation
Device Viewer
Special Documentation (SD) -
Proline Promag
Information on the Pressure Equipment Directive
Special Documentation
Electromagnetic flow measuring system
Special Documentation (SD) -
Proline Promag/Promass
EtherNet/IP
System integration
Special Documentation (SD) -
Levelflex FMP5x, Micropilot FMR5x
Weather protection cover
Special Documentation (SD) -
Proline Promag 200
Manufacturer information regarding firmware
updates (NE 53)
New firmware version:
Promag 200 HART: 1.01.02Manufacturer Information (MI) -
Trait d'union 57 - Edition Process
Le Journal d'Information Endress+Hauser France
Customer Magazine (CM)07/13French -
Proline Promag 200
American version: Electromagnetic flow measurement in efficient two-wire
technology
for the chemical industry – For the highest safety round the clockInnovations (IN)03/16English -
Promag P200
Magnetisch-induktives Durchflussmessgerät zur bidirektionalen Messung
von
Flüssigkeiten mit einer Mindestleitfähigkeit von ≥ 20 μS/cm.Tender Text02/18German -
GSD Single, GSD_PA_FL_Promag200_0x1563_0x01_0x01, 17.06.2015 (Flow, Proma
g 200)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_Promag200_0x0048_0x01_0x01, 31.03.2014 (Flow, Promag 200, 0x0048)
HART,
PDM Version: 6.0 SP5, 6.1Electronic Data Description (EDD)1.00.01Language neutral -
EDD Single, PDM_HART_FL_Promag200_0x1148_0x02_0x02, 19.02.2019 (Flow, Promag 200, 0x0048)
HART,
PDM Version: 6.1, 8.2Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_FF_FL_Promag200_0x1048_0x01_0x02, 14.03.2018 (Flow, Promag 200, 0x1048)
FOUNDATION Fieldbus H1,
AMS Version: 12.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_Promag200_0x0048_0x02_0x01, 10.11.2015 (Flow, Promag 200)
HART,
Field Device Manager Version: R430.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EDD_FF_FL_Promag200_0x1048_0x01_0x02, 14.03.2018 (Flow, Promag 200, 0x1048)
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 6Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_FF_FL_Promag200_0x1048_0x01_0x02, 14.03.2018 (Flow, Promag 200, 0x1048)
FOUNDATION Fieldbus H1,
AMS Version: 11.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_FL_Promag200_0x1563_0x01_0x01, 17.06.2015 (Flow, Proma
g 200)
PROFIBUS PA,
PDM Version: 6.1, 8.2Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_FL_Promag200_0x0048_0x01_0x01, 20.08.2019 (Flow, Promag 200, 0x0048)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_FL_Promag200_0x0048_0x02_0x01, 20.08.2019 (Flow, Promag 200, 0x0048)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS13_FF_FL_Promag200_0x1048_0x01_0x02, 14.03.2018 (Flow, Promag 200, 0x1048)
FOUNDATION Fieldbus H1,
AMS Version: 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS10_FF_FL_Promag200_0x1048_0x01_0x02, 14.03.2018 (Flow, Promag 200, 0x1048)
FOUNDATION Fieldbus H1,
AMS Version: 10.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_Promag200_0x0048_0x02_0x01, 20.08.2019 (Flow, Promag 200, 0x0048)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_Promag200_0x0048_0x01_0x01, 20.08.2019 (Flow, Promag 200, 0x0048)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, Promag200_5x2B_PA_FW1_00_zz_Dev_Rev_1, 21.10.2020 (Flow, Promag 200, 0x1563)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.7.0.57Language neutral -
DTM Single, Promag_200_5x2B_FF_FW_1_00_zz_Dev_Rev_1, 06.11.2020 (Flow, Promag 200)
FOUNDATION Fieldbus H1,
ArchestrA IDE Version: 3.6.001
DeviceCare Version: 1.07.00
Field Device Manager Version:R430.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
Plant Resource Manager Version: R3.12Device Type Manager (DTM)1.6.0.73Language neutral -
DTM Single, Promag200_5x2B_HART_FW1_01_zz_Dev_Rev_2, 27.10.2020 (Flow, Promag 200, 0x0048)
HART,
DeviceCare Version: 1.07.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.11.00Device Type Manager (DTM)1.5.0.219Language neutral -
DTM Single, Promag200_5x2Bxx_HART_FW1_00_zz_Dev_Rev_1, 23.10.2020 (Flow, Promag 200, 0x0048)
HART,
DeviceCare Version: 1.07.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.0.0.0Language neutral -
Faceplate Library, PRM_HART_Package_Flow_1_08_00, 22.07.2015 (Flow)
HART,
Plant Resource Manager Version: R3.02, R3.05, R3.10, R3.11, R3.12Faceplate1.08.00Language neutral -
Faceplate Single, PRM_HART_FL_Promag200_0x0048_0x01_0x01, 31.03.2014 (Flo
w, Promag 200, 0x0048)
HART,
Plant Resource Manager Version: R3.05Faceplate1.00.01Language neutral -
Faceplate Single, PRM_FF_FL_Promag200_0x1048_0x01_0x01, 12.10.2018 (Flow, Promag 200, 0x1048)
FOUNDATION Fieldbus H1,
Plant Resource Manager Version: R3.12Faceplate1.00.00Language neutral -
Faceplate Single, PRM_HART_FL_Promag200_0x0048_0x02_0x01, 12.11.2015 (Flow, Promag 200)
HART,
Plant Resource Manager Version: R3.12Faceplate1.00.00Language neutral -
Note Single, Release_Notes_for_AMS_HART_Flow, 15.06.2018 (Flow)
HART,
AMS Version: AnyNote1.00.00Language neutral -
Note Single, Release_Notes_Promag200_FF_0x1048_0x01, 23.08.2018 (Flow, Promag 200, 0x1048)
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: AnyNote1.00.00Language neutral -
Verification DTM Library, VerificationDTM_FLOW_PROFIBUS_PA, 15.05.2020 (Flow)
PROFIBUS PA,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_FOUNDATION_Fieldbus, 15.05.2020 (Flow)
FOUNDATION Fieldbus H1,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_HART, 15.05.2020 (Flow)
HART,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Promag P, Promag H, Promag E, Promag 55, Promag 53, Promag 50, Promag 10, Ersatzteil, Dosimag OEM, Dosimag
Product Code: 5P5B-, 5P3B-, 5H5B-, 5H3B-, 5P1B-, 5H1B-, 53H-, 53P-, 50H-, 5P2B-, 5H2B-, 50P-, 55S-, 55H-, O5H1B-, DKH-, DK5HB-, DK5G-, 5SH-, 5RH-, 5CH-, 5BH-, 5DH-, 10H-
Declaration Number: HE_01074_01.18Manufacturer DeclarationGerman , English -
Promag 10, Promag 50, Promag 53, Promag 55, Promag P
Product Code: 10P-, 50P-, 53P-, 55S-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5PBB-, O5P1B-, O5P2B-
Declaration Number: HE_01038_04.18
Manufacturer Specification: Food hygiene, 1935/2004Manufacturer DeclarationGerman , English -
Dosimag, Dosimag OEM, Ersatzteil, Promag 10, Promag 50, Promag 53, Promag 55, Promag H, Promag P
Product Code: 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5RH-, 5SH-, DDA-, DK5G-, DK5HA-, DK5HB-, DKH-, O5H1B-, O5H2B-, O5P1B-, O5P2B-, 5H5B-, 5H3B-, 5H2B-, 5H1B-, 5H-, 5DH-, 5CH-, 5BH-, 55S-, 55H-, 53P-, 53H-, 50P-, 50H-, 10P-, 10H-
Declaration Number: FDA_00131_04.17FDA DeclarationGerman , English -
Promag E, Promag H, Promag P
Product Code: 5E2B-, 5H2B-, 5P2B-
Declaration Number: EC_00278_02.16EU DeclarationGerman , English , French -
Promag E, Promag H, Promag P
Product Code: 5E2B-, 5H2B-, 5P2B-
Declaration Number: EC_00277_03.16EU DeclarationGerman , English , French -
Promag 10, Promag 50, Promag 53, Promag 55, Promag P
Product Code: O5P1B-, 5P5B-, 5P3B-, 5P2B-, 5P1B-, 55S-, 53P-, 50P-, 10P-
Declaration Number: EC_00697_03.18EU DeclarationGerman , English -
Promag E, Promag H, Promag P
Product Code: 5E2B-, 5H2B-, 5P2B-
Declaration Number: EC_00279_02.16EU DeclarationGerman , English , French -
Promag 10, Promag 50, Promag 53, Promag 55, Promag P
Product Code: 10P-, 50P-, 53P-, 55S-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, O5P1B-
Declaration Number: EC_00696_03.18EU DeclarationGerman , English -
Promag 10, Promag 50, Promag 53, Promag 55, Promag P
Product Code: 10P-, 50P-, 53P-, 55S-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5PBB-, O5P1B-
Declaration Number: EC_00696_04.18EU DeclarationGerman , English -
Promag 10, Promag 50, Promag 53, Promag 55, Promag P
Product Code: O5P1B-, 5PBB-, 5P5B-, 5P3B-, 5P2B-, 5P1B-, 55S-, 53P-, 50P-, 10P-
Declaration Number: EC_00697_04.18EU DeclarationGerman , English -
Promag E, Promag P, Promag W
Product Code: 5E1B-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W3B-, 5W4C-, 5W5B-, O5E1B-, O5P1B-, O5P2B-
Declaration Number: EC_00064_05.15EU DeclarationGerman , English , French -
Promass K, Promass O, Promass P, Promass Q, Promass S, Promass X, Prosonic Flow 91, Prosonic Flow 92, Prosonic Flow 93, Prosonic Flow G, Prowirl D, Prowirl F, Prowirl O, Prowirl R, t-mass, t-mass A, t-mass B, T-MASS F, T-MASS I, Promass I, CNGmass, Dosimag, Dosimass, LNGmass, LPGmass, Promag 10, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W, Promass 40, Promass 80, Promass 83, Promass 84, Promass E, Promass F, Promass H
Product Code: 8I3B-, 8I1B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8F2B-, 8F1B-, 8E5B-, 8E3B-, 8E2C-, 8E2B-, 8E1C-, 8E1B-, 8E-, 84X-, 84F-, 83X-, 83F-, 80F-, 7R2C-, 8I5B-, 8K1B-, 8O3B-, 8O5B-, 8P1B-, 8P3B-, 8P5B-, 8Q3B-, 8Q5B-, 8S1B-, 8S1C-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, 91W-, 92F-, 93C-, 93W-, 9G3B-, 9G5B-, DDA-, 7R2B-, 10D-, 10E-, 10H-, 10L-, 10P-, 10W-, 40E-, 5D4B-, 5D4C-, 5E1B-, 5E2B-, 5H-, 5H1B-, 5H2B-, 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 7O2C-, 7O2B-, 7F2C-, 7F2B-, 7D2C-, 7D2B-, 6I5B-, 6I3B-, 6F5B-, 6F3B-, 6BAB-, 6AAB-, 65I-, 65F-, 5W8C-, 5W8B-, 5W5B-, 5W4D-, 5W4C-, 5W4B-, 5W3B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.03271/20MiscellaneousRussian -
Dosimag, Promag 10, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W3B-, 5W4B-, 5W4C-, 5W5B-, 5H2B-, 5H1B-, 5H-, 5E2B-, 5E1B-, 5D4C-, 5D4B-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia (TR CU)
Approval Number: EAEC N RU D-CH.AD07.B.03271/20MiscellaneousRussian -
Promag 10, Promag 50, Promag 51, Promag 53, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W
Product Code: 53L-, 53P-, 53W-, 5D4B-, 5D4C-, 5E1B-, 5E2B-, 5H1B-, 5H2B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5W4B-, 5W4C-, 5W8B-, 53H-, 53E-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 50D-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC BY_112 11.01. TP020 003 126MiscellaneousRussian -
Promag W, Promag P, Promag L, Promag H, Promag E, Promag D, Promag 55, Promag 53, Promag 51, Promag 50, Promag 10, Dosimag, Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Promass 84, Promass 83, Promass 80, Dosimass OEM
Product Code: 5D4C-, 5P5B-, 5W5B-, 5P3B-, 5H5B-, 5W3B-, 5W4C-, 5L4C-, 53P-, 53W-, 5P1B-, 5H1B-, 5H3B-, 50W-, 50P-, 50H-, 53H-, 5E1B-, 55S-, 5P2B-, 53L-, 55H-, 5H2B-, 50L-, 53E-, 50D-, 50E-, 51W-, 5H-, 5L4B-, 5W4D-, 5W4B-, 5W8B-, 5W8C-, DDA-, 5D4B-, 10D-, 10E-, 10H-, 10P-, 10W-, 10L-, 51P-, 8E5B-, 8F1B-, 8F2B-, 8F3B-, 8H1B-, 8H3B-, 8H5B-, 8I1B-, 8I3B-, 8I5B-, 8O1B-, 8O3B-, 8P1B-, 8P3B-, 8P5B-, 8Q3B-, 8Q5B-, 8S1B-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, 80A-, 80E-, 80F-, 80I-, 80P-, 80S-, 83A-, 83E-, 83F-, 83H-, 83I-, 83P-, 83S-, 83X-, 84F-, 84X-, 8A1B-, 8A3B-, 8A5B-, 8BE-, 8E1B-, 8E2B-, 8E3B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.02246/20MiscellaneousRussian -
Promag 10, Promag 50, Promag 51, Promag 55, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W
Product Code: 55H-, 55S-, 5D4C-, 5E1B-, 5H2B-, 5H3B-, 5L4B-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W4C-, 5W8B-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 50D-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC RU D-CH.MU62.B.02333MiscellaneousRussian -
Promag P, Promag H, Promag E
Product Code: 5H2B-, 5P2B-, 5E2B-, O5H2B-, O5P2B-
Region/Country: Brazil
Approval Agency: TÜV
Category: zone 2
Protection: Ex nAExplosion ProtectionPortuguese -
Promag P, Promag H, Promag E
Product Code: 5H2B-, 5P2B-, 5E2B-, O5H2B-, O5P2B-
Region/Country: China
Approval Agency: NEPSI
Category: zone 2
Protection: Ex ic, Ex nAExplosion ProtectionEnglish -
Promag P, Promag H, Promag E
Product Code: 5H2B-, 5P2B-, 5E2B-, O5H2B-, O5P2B-
Region/Country: Brazil
Approval Agency: TÜV
Category: zone 1
Protection: Ex iaExplosion ProtectionPortuguese -
Promag P, Promag H, Promag E
Product Code: 5H2B-, 5P2B-, 5E2B-, O5H2B-, O5P2B-
Region/Country: China
Approval Agency: NEPSI
Category: zone 1, zone 21
Protection: Ex d [ia], Ex ia, Ex d [ia Ga]Explosion ProtectionChinese -
Promag E, Promag H, Promag P
Product Code: 5E2B-, 5H2B-, 5P2B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Protection: Ex ic IIC T6...T1 Gc, Ex ic [ia Ga] IIC T6...T1 Gc, Ex nA [ia Ga] IIC T6...T1 GcExplosion ProtectionRussian -
Promag P, Promag H, Promag W, Promag E
Product Code: 5H2B-, 5P2B-, 5E2B-, 5W2B-, O5E2B-, O5H2B-, O5P2B-, O5W2B-
Region/Country: Europe (ATEX)
Approval Agency: DEKRA
Category: II 2 D, II 2 G, II 2(1) D
Protection: Ex d [ia], Ex tb, Ex tb [ia Da]Explosion ProtectionEnglish -
Prowirl R, Prowirl O, Prowirl F, Prowirl D, Prowirl C, Prosonic Flow B, Promass F, Promass E, Promass A, Promag P, Promag H, Promag E
Product Code: O9B2B-, O5P2B-, O5H2B-, 9B2B-, 8F2B-, 8E2C-, 8E2B-, 8A2B-, 7R2C-, 7R2B-, 7O2C-, 7O2B-, 7F2C-, 7F2B-, 7D2C-, 7D2B-, 7C2B-, 5P2B-, 5H2B-, 5E2B-
Region/Country: India
Approval Agency: CC(O)E
Category: zone 1Explosion ProtectionEnglish -
Promag E, Promag H, Promag P
Product Code: 5E2B-, 5H2B-, 5P2B-, O5H2B-, O5P2B-
Region/Country: South Africa
Approval Agency: MTEx
Category: zone 1, zone 21
Protection: Ex ia, Ex tb, Ex tb [ia Da]Explosion ProtectionEnglish -
Promag E, Promag H, Promag P, Promag W
Product Code: 5E2B-, 5H2B-, 5P2B-, 5W2B-
Region/Country: USA, Canada
Approval Agency: CSA
Category: I/1/A,B,C,D/T6...T1
Protection: DIP, ISExplosion ProtectionEnglish -
Promag P, Promag H, Promag W, Promag E
Product Code: 5H2B-, 5P2B-, 5E2B-, 5W2B-, O5E2B-, O5H2B-, O5P2B-, O5W2B-
Region/Country: Europe (ATEX)
Approval Agency: DEKRA
Category: II 3 G
Protection: Ex nAExplosion ProtectionEnglish -
Promag E, Promag H, Promag P, Promag W
Product Code: 5E2B-, 5H2B-, 5P2B-, 5W2B-
Region/Country: USA, Canada
Approval Agency: CSA
Category: I/2/A,B,C,D/T6...T1, II,III/1/E,F,G/
Protection: DIP, NIExplosion ProtectionEnglish -
Promag E, Promag H, Promag P
Product Code: 5E2B-, 5H2B-, 5P2B-, O5H2B-, O5P2B-
Region/Country: South Africa
Approval Agency: MTEx
Category: zone 2
Protection: Ex ic, Ex ic [ia Ga], Ex nA, Ex nA [ia Ga], Ex ecExplosion ProtectionEnglish -
Promag H, Promag P
Product Code: 5H2B-, 5P2B-, O5H2B-, O5P2B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Protection: Ex ic IIC T6...T1 Gc, Ex ic [ia Ga] IIC T6...T1 Gc, Ex nA [ia Ga] IIC T6...T1 Gc, Ex d [ia] IIC T6...T1 Gb, Ex ia IIC T6...T1 Gb, Ex nA IIC T6...T1 Gc, Ex tb IIIC Txxx°C Db, Ex tb [ia Da] IIIC Txxx°C DbExplosion ProtectionRussian -
Promag W, Promag P, Promag H, Promag E
Product Code: 5H2B-, 5P2B-, 5E2B-, O5H2B-, O5P2B-
Region/Country: South Korea
Approval Agency: KTL
Category: zone 1, zone 21
Protection: Ex ia, Ex tbExplosion Protection -
Promag P, Promag H, Promag W, Promag E
Product Code: 5H2B-, 5P2B-, 5E2B-, 5W2B-, O5E2B-, O5H2B-, O5P2B-, O5W2B-
Region/Country: International (IECEx)
Approval Agency: DEKRA
Protection: Ex ia, Ex tb, Ex tb [ia Da]Explosion ProtectionEnglish -
Promag P, Promag H, Promag W, Promag E
Product Code: 5H2B-, 5P2B-, 5E2B-, 5W2B-, O5E2B-, O5H2B-, O5P2B-, O5W2B-
Region/Country: Europe (ATEX)
Approval Agency: DEKRA
Category: II 2 D, II 2 G, II 2(1) D
Protection: Ex ia, Ex tb, Ex tb [ia Da]Explosion ProtectionEnglish -
Promag E, Promag H, Promag P, Promag W
Product Code: 5E2B-, 5H2B-, 5P2B-, 5W2B-
Region/Country: USA, Canada
Approval Agency: CSA
Category: I/1/A,B,C,D/T6...T1, II,III/1/E,F,G/
Protection: DIP, XP/ISExplosion ProtectionEnglish -
Promag W, Promag P, Promag H, Promag E
Product Code: 5H2B-, 5P2B-, 5E2B-, O5H2B-, O5P2B-
Region/Country: South Korea
Approval Agency: KTL
Category: zone 1, zone 21
Protection: Ex d [ia], Ex tbExplosion Protection -
Promag H, Promag P
Product Code: 5H2B-, 5P2B-, O5H2B-, O5P2B-
Region/Country: India
Approval Agency: CC(O)E
Category: zone 1
Protection: Ex d [ia]Explosion ProtectionEnglish -
Promag E, Promag H, Promag P
Product Code: 5E2B-, 5H2B-, 5P2B-, O5H2B-, O5P2B-
Region/Country: China
Approval Agency: NEPSI
Category: zone 1, zone 21
Protection: Ex d [ia] IIC T6...T1 Gb, Ex ia IIC T6...T1 Gb, Ex d [ia Ga] IIC T6...T1 GbExplosion ProtectionChinese -
Promag P, Promag H, Promag W, Promag E
Product Code: 5H2B-, 5P2B-, 5E2B-, 5W2B-, O5E2B-, O5H2B-, O5P2B-, O5W2B-
Region/Country: International (IECEx)
Approval Agency: DEKRA
Protection: Ex ic, Ex ic [ia Ga], Ex nAExplosion ProtectionEnglish -
Promag E, Promag H, Promag P
Product Code: 5E2B-, 5H2B-, 5P2B-, O5H2B-, O5P2B-
Region/Country: China
Approval Agency: NEPSI
Category: zone 2
Protection: Ex ic IIC T6...T1 Gc, Ex ic [ia Ga] IIC T6...T1 Gc, Ex nA IIC T6...T1 Gc, Ex nA [ia Ga] IIC T6...T1 GcExplosion ProtectionEnglish -
Promag E, Promag H, Promag P, Prowirl C, Prowirl D, Prowirl F, Prowirl O, Prowirl R
Product Code: O7R2C-, O7F2C-, O7D2C-, O5P2B-, O5H2B-, 7R2C-, 7R2B-, 7O2C-, 7O2B-, 7F2C-, 7F2B-, 7D2C-, 7D2B-, 7C2B-, 5P2B-, 5E2B-
Region/Country:
Approval Agency:
Protection: Ex ia, Ex ic, Ex nA, Ex tb, Ex ec, Ex dbExplosion ProtectionEnglish -
Promag P, Promag H, Promag W, Promag E
Product Code: 5H2B-, 5P2B-, 5E2B-, 5W2B-, O5E2B-, O5H2B-, O5P2B-, O5W2B-
Region/Country: International (IECEx)
Approval Agency: DEKRA
Protection: Ex d [ia], Ex tb, Ex tb [ia Da]Explosion ProtectionEnglish -
Promag E, Promag H, Promag P, Promag W
Product Code: 5E2B-, 5H2B-, 5P2B-, O5H2B-, O5P2B-, S5H2B-, S5P2B-
Region/Country: Japan
Approval Agency: CML
Protection: Ex ia, Ex dbExplosion ProtectionJapanese -
Promag 10, Promag 50, Promag 51, Promag 53, Promag D, Promag L, Promag P, Promag W
Product Code: 5L4B-, 5L4C-, 5L8B-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W4B-, 5W4C-, 5W5B-, 5W8B-, O5P1B-, O5P2B-, O5W1B-, 10D-, 10L-, 10P-, 10W-, 50D-, 50L-, 50P-, 50W-, 51P-, 51W-, 53P-, 53W-, 5D4B-, 5D4C-
Region/Country: USA
Approval Agency: NSFHygienic EquipmentEnglish -
Promag 10, Promag W, Promag L, Promag 50, Promag 51, Promag 53, Promag 55, Promag P
Product Code: 5W5B-, 5W3B-, 5W4C-, 5L4C-, 53W-, 50W-, 55S-, 53L-, 50L-, 51W-, 5W4B-, 5L4B-, 5W8C-, 5W8B-, 5L8B-, 10W-, 10L-, O5P2B-, O5P1B-, 5P5B-, 5P3B-, 5P2B-, 5P1B-, 10P-, 50P-, 51P-, 53P-
Region/Country: France
Approval Agency: ACSHygienic EquipmentFrench -
Promag H, Promag P
Product Code: 5H2B-, 5P2B-
Region/Country: International
Approval Agency: Fieldbus FoundationFieldbus ConformanceEnglish -
Promag H, Promag P
Product Code: 5H2B-, 5P2B-
Region/Country: International
Approval Agency: FieldComm GroupFieldbus ConformanceEnglish -
Promag H, Promag P
Product Code: 5H2B-, 5P2B-
Region/Country: International
Approval Agency: PI, PROFIBUS InternationalFieldbus ConformanceEnglish -
Promag W, Promag P, Promag L, Promag H, Promag E, Promag D, Promag 55, Promag 53, Promag 51, Promag 50, Promag 10
Product Code: 55S-, 5D4B-, 5D4C-, 5E1B-, 5H1B-, 5H2B-, 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W4B-, 5W4C-, 5W5B-, 5W8B-, 55H-, 53W-, 53P-, 53L-, 53H-, 53E-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Uzbekistan
Approval Agency: UZS
Approval Number: 02.6720MetrologyRussian -
Promag D, Promag P, Promag W, Promag H, Promag L, Promag E
Product Code: 5W8B-, 5W4C-, 5L4C-, 5P1B-, 5H1B-, 5H3B-, 5E1B-, 5P2B-, 5D4C-, 5H2B-, 5W4B-, 5L4B-, 5E2B-, 5D4B-
Region/Country: Russia
Approval Agency: Rosstandart
Approval Number: CH.C.29.004.А NO. 59660/1MetrologyRussian -
Promag E, Promag H, Promag P
Product Code: 5E2B-, 5H2B-, 5P2B-
Region/Country: Germany
Approval Agency: TÜV
Approval Number: PC/209/03/144/03-04/14Heartbeat TechnologyGerman , English
Accessories / Spare parts
-
-
Nr 34 Order code 71164940
I/O module, 2-wire, PA/FF, PFS, Ex, V2
Non-Ex, Ex. PROFIBUS PA, FOUNDATION Fieldbus. PFS=switch output. Version 2. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57. Usage: Promass 200, Prowirl 200, Promag 200.
-
-
-
Order code 71128617
Overvoltage protection (OVP10),1-Channel
4-20mA HART. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/ FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Order code 71128619
Overvoltage protection (OVP20),2-Channel
4-20mA HART, PROFIBUS PA, FOUNDATION Fieldbus, Imp./Freq./Switch output. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/ FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Order code 71197334
Transmitter electronics FHX50
Consists of: electronics, ribbon cable. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57. Usage: Promass200, Prowirl 200, Promag 200, Prosonic Flow 200.
-
Order code
Remote display FHX50 please order with separate order structure.
-
Order code 71296840
M12-female plug connector, VA
To connect FHX50. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Not for dust Ex. Usage: Prowirl 200, Promass 200, Promag 200, Prosonic Flow 200.
-
-
-
Nr 30 Order code XPD0008-
-
-
-
Order code 71206552
-
Order code 71206554
-
-
-
Nr 34 Order code XPD0015-
-
-
-
Order code 71206555
-
Order code 71206556
-
-
-
Nr 34 Order code XPD0016-
I/O module, 2-wire, 4-20mA,HART, PFS, Ex
Non-Ex, Ex. 1x current output HART. 1x PFS= pulse/freq./switch output.
-
-
-
Nr 37 Order code 71110280
Terminal set 2-wire, I/O module
Consists of: 4x terminal 2-pole, green. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Nr 40 Order code XPD0024-
Display module, SD02, push buttons
For housing: GT18, GT19, GT20. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67, FHX50. Promass 200/TB2, Prosonic Flow 200, t-mass 150, Promag 200, Prowirl 200. Consists of: Display SD02, helix cable, ribbon cable, connector cover.
-
Nr 40 Order code XPD0025-
Display module, SD03, Touch Control
For housing: GT18, GT19, GT20. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67, FHX50. Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200. Consists of: Display SD03 illuminated, ribbon cable, connector cover.
-
-
-
Nr 20 Order code 71110299
Cover GT20 Alu, HNBR
Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Nr 20 Order code 71110297
Cover GT20 Alu, sight glass, HNBR
Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Nr 25 Order code 71110301
Cover GT20 Alu, Terminal Ex, HNBR
Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: terminal compartment, not for Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Nr 25 Order code 71110302
Cover GT20 Alu, Terminal Ex d, HNBR
Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: terminal compartment Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Nr 25 Order code 71185517
Cover GT20 Alu, Terminal, OVP, HNBR
Material: aluminium. O-ring EPDM, PTFE coated. Usage: terminal compartment, for overvoltage protection, not for Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Nr 15 Order code 50103658
Kit 10 cable glands M20x1,5 grey
-
Nr 15 Order code 50098036
Kit 10 cable glands M20x1.5 Ex
-
Nr 15 Order code 50098041
Kit 10 ext. M20x1.5/G 1/2" (plug PVC)
-
Nr 15 Order code 71115505
Kit 10 ext. M20x1,5/G 1/2" (plug brass)
-
Nr 15 Order code 50098042
Kit 10 ext. M20x1.5/NPT 1/2" (plug PVC)
-
Nr 15 Order code 71115509
Kit 10 ext. M20x1,5/NPT1/2"(plug brass)
-
Nr 15 Order code 50098037
Kit Cable gland Profibus PA
-
Nr 15 Order code 50094984
Kit Cable gland Found. Fieldbus
-
-
-
Nr 65 Order code 71110303
Sealing set GT18/GT19/GT20, EPDM, HNBR
Consists of: O-ring 88.5x3.53 EPDM/PTFE, cover electronics compartment, housing GT19. O-Ring 88.5x3.53 NBR, cover electronics compartment, housing GT18, GT20. O-ring 91.67x3.53 EPDM/PTFE, cover terminal compartment, housing GT19. O-Ring 91.67x3.53 NBR, cover terminal compartment, housing GT18, GT20. O-ring 50.39x3.53 EPDM/PTFE, housing/sensor. FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Nr 19 Order code 71115175
Housing filter Brass/Ni GT19/20, 1 set
Consists of: 2x filter plug brass nickel, pressure compensation filter. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Nr 17 Order code 71115176
Set housing securing clamps
Usage: housing GT18/GT19/GT20, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Order code 71162242
Weather prot. cover GT18/GT19/GT20, 316L
Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/FMR54/ FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Order code 5X2BXX-
Transmitter Promag 200, 5X2BXX
-
Order code DK5GC-
-
Order code DK5GD-
Promag, grounding disc/protection disc
Includes 1 grounding disc/protection disc
-
Order code XPRFID-
-
-
Predecessor