Spezifikation im Überblick
-
Max. Prozessdruck (statisch)
40 bar (580 psi)
-
Maximale Standard Eintauchlänge
48" (1.219 mm)
Anwendungsgebiet
Best applicable for use in hygienic or aseptic pipes and containers or tanks even with very small immersion lengths. It meets increased protection requirements of the temperature sensor regarding physical and chemical effects. Ideally suited to all measuring points that require regular re-calibration by simply replacing the insert in closed processes.
Specially designed for use in hygienic and aseptic applications in the Food & Beverages and Life Sciences industries
Pressure range up to 40 bar (580 psi)
For increased protection requirements of the temperature sensor regarding physical and chemical effects
For use in pipes and containers or tanks
Ideally suited to all measuring points that require regular recalibration by simply replacing the insert in closed processes
Vorteile
-
iTHERM QuickNeck – cost and time savings thanks to simple, tool-free recalibration of the insert used
-
All common hygienic process connections
-
International certification: hygiene standards as per 3-A, EHEDG, ASME BPE, FDA, TSE Certificate of Suitability
-
Fast response time owing to reduced tips with thin walls
-
State of the art Tee and Elbow elements, without welds and dead legs and with best in class hygienic design
Vorgänger
-
Perfekt für Basisanwendungen
- Einfachste Auswahl, Installation und Bedienung
Leistungsumfang
Einfache Auswahl
-
Optimierter Leistungsumfang für Standardanwendungen
- Einfache Auswahl, Installation und Bedienung
Leistungsumfang
Einfache Auswahl
-
Maximaler Leistungsumfang für breiten Einsatzbereich
- Einfache Installation und Bedienung
Leistungsumfang
Einfache Auswahl
-
Höchster Nutzen durch Spezialisierung auf Anwendung
- Einfache Installation und Bedienung
Leistungsumfang
Einfache Auswahl
Variabel
FLEX Auswahl | Leistungsumfang | Einfache Auswahl |
---|---|---|
Fundamental Auswahl Perfekt für Basisanwendungen |
Leistungsumfang
|
Einfache Auswahl
|
Lean Auswahl Optimierter Leistungsumfang für Standardanwendungen |
Leistungsumfang
|
Einfache Auswahl
|
Extended Auswahl Maximierte Effizienz in Standardanwendungen im Life Cycle |
Leistungsumfang
|
Einfache Auswahl
|
Xpert Auswahl Herausragende Leistung für besondere Anwendungen |
Leistungsumfang
|
Einfache Auswahl
Variabel |
-
-
Technische Information (TI)
iTHERM TT412
Thermometer thermowell for hygienic and aseptic applications
EN DE 29/07/202213/01/202131/10/201804/08/2017Sprache:
Englisch
Version:
29/07/2022
Dateigröße:
1.2 MB
Dateiname:
TI01350TEN_0422-00.pdf
-
-
-
Technische Information (TI)
Einschweißadapter, Prozessadapter und Flansche
Füllstand- und Druckmesstechnik
EN DE 28/10/202130/07/202119/06/202008/11/201917/08/2017Sprache:
Deutsch
Version:
28/10/2021
Dateigröße:
2.9 MB
Dateiname:
TI00426FDE_2321.pdf
-
-
-
Sonderdokumentation (SD)
Device viewer
Technical documentation in other languages
Sprache:
Englisch
Version:
14/07/2021
Dateigröße:
478.5 KB
Dateiname:
SD02429R09EN_0121.pdf
-
-
-
PU (Veröffentlichungen)
iTHERM TT411, TT412 Innovatives Schutzrohr, für Hygieneanwendungen entwickelt
Moderne T- und Eck-Schutzrohre Die neuen iTHERM TT4xx T- und Eck-Schutzrohrelemente sind ideal für Anwendungen in der Pharma- sowie der Lebensmittel- & Getränkeindustrie geeignet, in welchen eine hygienische Bauformund optimierte Messungen oberste Priorität haben.
EN DE 14/09/202208/08/2022Sprache:
Deutsch
Version:
14/09/2022
Dateigröße:
1.2 MB
Dateiname:
PU01246T_09_DE_04.22 TT4xx.pdf
-
-
-
Hersteller Erklärungen
Product family: Accessories: Pipe thermowell, Magphant, PROCESS RTD HYGIENIC, RTD-THERMOMETER
Product root: DTT35-, TK40-, TM311-, TM371-, TM372-, TM401-, TM402-, TM411-, TM412-, TMR35-, TT411-, TT412-, TTR35- {Z MMM_DECLARATION_NUMBER}: HE_01097_01.19 Manufacturer specification: Food hygiene
Sprache:
Englisch
Version:
28/03/2022
Dateigröße:
367.6 KB
Dateiname:
HE_01097_02.23 MD-22010 19002.pdf
-
-
-
Hersteller Erklärungen
Product family: Accessories: Pipe thermowell, Accessories: Inserts, PROCESS RTD HYGIENIC, RTD thermometer
Product root: TK40-, TM371-, TM372-, TM401-, TM402-, TM411-, TM412-, TMR35-, TS111-, TS212-, TT411-, TT412- Declaration number: HE_00886_01.17 Additional information: TSE compliance, animal fat free
EN DE 23/10/2017Sprache:
Englisch
Version:
23/10/2017
Dateigröße:
160.7 KB
Dateiname:
HE_00886_0117.pdf
-
-
-
Hersteller Erklärungen
Product family: Accessories: Pipe thermowell, Magphant, PROCESS RTD HYGIENIC, RTD-THERMOMETER
Product root: DTT35-, TK40-, TM311-, TM371-, TM372-, TM401-, TM402-, TM411-, TM412-, TMR35-, TT411-, TT412-, TTR35- Declaration number: HE_00099_05.15 Manufacturer specification: Food hygiene, 10/2011, 1935/2004
EN DE 10/12/2020Sprache:
Englisch
Version:
10/12/2020
Dateigröße:
1.8 MB
Dateiname:
HE_00099_05.15.pdf
-
-
-
Hersteller Erklärungen
Product family: Process RTD hygienic
Product root: TK40-, TM401-, TM402-, TM411-, TM412-, TS111-, TS112-, TT411-, TT412- Declaration number: MD-12028A-9
Sprache:
Englisch
Version:
10/01/2013
Dateigröße:
872.7 KB
Dateiname:
MD-12028a_09_e.pdf
-
-
-
Hersteller Erklärungen
Product family: Accessories: Bar stock thermowell, ACCESSORIES: PIPE THERMOWELL, ACCESSORIES: T_INSERTS, Magphant, PROCESS RTD GENERAL PURPOSE, PROCESS RTD HYGIENIC, RTD thermometer
Product root: DTT31-, DTT35-, TK40-, TM101-, TM111-, TM121-, TM131-, TM311-, TM371-, TM372-, TM401-, TM402-, TM411-, TM412-, TMR35-, TS111-, TS212-, TT131-, TT151-, TT411-, TT412- Declaration number: HE_01494_01.21 Manufacturer specification: Food hygiene Additional information: BSE, TSE
Sprache:
Englisch
Version:
14/02/2021
Dateigröße:
316.5 KB
Dateiname:
HE_00886_05_17.pdf
-
-
-
FDA Erklärung
Product family: Accessories: Pipe thermowell, Magphant, PROCESS RTD HYGIENIC, RTD-THERMOMETER
Product root: DTT35-, TK40-, TM311-, TM371-, TM372-, TM401-, TM402-, TM411-, TM412-, TMR35-, TT411-, TT412-, TTR35- Declaration number: FDA_00127_03.17 FDA specification: Sealing
EN DE 20/07/2020Sprache:
Englisch
Version:
20/07/2020
Dateigröße:
450.8 KB
Dateiname:
FDA_00127_03.17.pdf
-
-
-
Hygieneausstattung
Product family: Accessories: Pipe thermowell, Magphant, PROCESS RTD HYGIENIC, RTD-THERMOMETER
Product root: DTT35-, TK40-, TM311-, TM371-, TM372-, TM401-, TM402-, TM411-, TM412-, TMR35-, TT411-, TT412-, TTR35- Region: Europe Approval agency: TU München Hygienic equipment: EHEDG
Sprache:
Englisch
Version:
01/01/2023
Dateigröße:
1.3 MB
Dateiname:
EHEDG-C1900070 2023.pdf
-
-
-
Hygieneausstattung
Product family: Accessories: Pipe thermowell, Magphant, PROCESS RTD HYGIENIC, RTD-THERMOMETER
Product root: DTT35-, ODTT35-, OTM311-, OTMR35-, OTR35-, TE411-, TK40-, TM311-, TM371-, TM372-, TM401-, TM402-, TM411-, TM 412-, TMR35-, TT411-, TT412-, TTR35- Region: Canada, USA Approval agency: 3-A Sanitary Standards {ZMMM_HYGIENIC_EQUIPME NT}: 005 Hygienic standard: 74-07
Sprache:
Englisch
Version:
01/01/2023
Dateigröße:
203.5 KB
Dateiname:
3-A 1144 2023 74-07.pdf
-
-
-
Druckausrüstung
Product family: Accessories: Pipe thermowell, Process RTD hygienic
Product root: TM411-, TM412-, TT411-, TT412- Region: Canada (CRN) Approval agency: CRN
Sprache:
Englisch
Version:
15/04/2019
Dateigröße:
18.3 MB
Dateiname:
Accepantce letters TT41x_Iss.3.pdf
-