T53
Explosion proof TC thermometer, US style

T53
Explosion proof TC thermometer, US style ©Endress+Hauser

Safe monitoring of process temperatures in challenging applications e. g. in the Oil & Gas industry

The robust thermometer is designed for use in demanding and safety relevant applications e.g. in Chemical, Oil & Gas and Energy industry. Harsh environments, corrosive substances and highest pressures can be handled by the use of robust thermowells and special materials. An optional head transmitter with all common communication protocols makes the device ready to use with enhanced measurement accuracy and reliability compared to directly wired sensors. Flexible configuration possible.

  • Vorteile

    • FM/CSA XP Class I, Div. 1 approved temperature assemblies for maximum safety

    • One source shopping for temperature measurement solutions. World class transmitter with integrated sensor offering for heavy process industry applications

    • Remove and install...

  • Anwendungsgebiet

    The sensor assembly can be used in process industries such as:

    • Chemicals

    • Petrochemical

    • Refineries

    • Offshore Platforms

Funktionen und Spezifikationen

Zurück

Details

  • Messprinzip

    Thermoelement

  • Merkmal / Anwendung

    amerikanische Bauart

    modulares Thermometer

    für heavy duty Anwendungen

    Gewindeprozessanschluss

    mit Verlängerung

    inkl. Schutzrohr
    inkl. Schutzrohr (Metall)

  • Anschlusskopf

    TMT162 - Alu - Feldgehäuse mit/ohne Display

    TMT162 Edelstahlguss mit/ohne Display

    TMT142 - Alu - Feldgehäuse mit/ohne Display

    TA30H - Alu mit/ohne Display

  • Schutzrohr

    gebohrt (aus Vollmaterial)

  • Messeinsatz

    mineralisoliert (MI), biegsam

  • Außendurchmesser Schutzrohr / Messeinsatz

    0,63'' ...1,31'' (15,88 mm ... 33,40 mm)

  • Max. Eintauchlänge auf Anfrage

    bis 22,5" (571 mm)

    andere auf Anfrage

  • Werkstoff Schutzrohr

    1.4401 (316)

  • Optionale Beschichtung

    verfügbar auf Anfrage

  • Prozessanschluss

    Außen-Gewinde:

    NPT1/2"

    NPT3/4"

    NPT1"

    Einschweißausführung

    Sockelschweißausführung

  • Form der Spitze

    reduziert

    verjüngt

  • Oberflächengenauigkeit Ra

    32 μin (0.80 μm)

  • Arbeitsbereich

    Typ T:

    -270 °C ...370 °C

    (-454 °F ...698 °F)

    Typ J:

    -210 °C ...720 °C

    (-346 °F ...1.328 °F)

    Typ E:

    -270 °C ...820 °C

    (-454 °F ...1.508 °F)

    Typ K:

    -270 °C ...1.150 °C

    (-454 °F ...2.102 °F)

    Typ N:

    -270 °C ...1.150 °C

    (-454 °F ...2.102 °F)

  • Max. Prozessdruck (statisch)

    Standard gem. ASTM E-230

    Special gem. ASTM E-230

  • Genauigkeit

    Standard gem. ASTM E-230

    Special gem. ASTM E-230

  • Ansprechzeit

    abhängig vom Aufbau

    63% rt = 15,0 s

  • Aufnahme Kopftransmitter

    ja (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Ex - Zulassungen

    FM XP

    CSA XP

    FM/CSA XP

    CSA GP

  • Zertifikate

    SIL (nur Transmitter)

Dokumente / Handbücher / Software

Zubehör / Ersatzteile

Nr
Order code
Specification